{"id":28598,"date":"2026-11-21T14:42:24","date_gmt":"2026-11-21T11:42:24","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T14:54:12","modified_gmt":"2026-11-21T11:54:12","slug":"victaulic-fl-sr-st-k11-2-storage-sprinkler","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/victaulic-fl-sr-st-k11-2-storage-sprinkler\/","title":{"rendered":"K11.2 Storage Sprinkler for Warehouses: Victaulic FL-SR\/ST V3403 Upright and V3407 Pendent"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28598\" class=\"elementor elementor-28598 elementor-28597 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ffd1521 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"ffd1521\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cd6e983 elementor-widget elementor-widget-text-editor\" data-id=\"cd6e983\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>K11.2 storage sprinkler<\/strong> has a larger orifice than an office sprinkler and delivers more water at the same pressure, which is why it is used in warehouses and storage areas that need higher water densities. In Saudi Arabia AZEIDK supplies <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-sr-st-k11-2-storage-sprinklers-v3403-and-v3407\/\">Victaulic FireLock FL-SR\/ST K11.2 storage sprinklers<\/a> in two models: <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-sr-st-k11-2-upright-storage-sprinkler-v3403\/\">V3403 upright<\/a> and V3407 pendent, both CMDA type with standard response.<\/p>\n<p>This guide explains what CMDA means, how it differs from ESFR, the datasheet specifications, and the storage types Victaulic lists for these heads together with the reference standard for each.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a341b00 elementor-widget elementor-widget-text-editor\" data-id=\"a341b00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>V3403 upright and V3407 pendent, both CMDA, standard response (SR).<\/li><li>K-factor 11.2 imperial, 16.1 S.I.<\/li><li>Connection 3\/4 in NPT, 20 mm BSPT or IGS grooved.<\/li><li>Maximum working pressure 175 psi, UL\/FM minimum operating pressure 7 psi, 100% factory test at 500 psi.<\/li><li>Temperature ratings in the cULus and FM tables: 57, 68, 79, 93 and 141\u00b0C.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ea9060 elementor-widget elementor-widget-text-editor\" data-id=\"4ea9060\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is a CMDA K11.2 storage sprinkler?<\/h2>\n<p>CMDA stands for Control Mode Density Area. The sprinkler controls the fire rather than suppressing it: the system is designed for a set water density over a calculated design area, so the heads contain the fire and limit its spread until the fire service deals with it.<\/p>\n<p>K11.2 means the head flows roughly twice as much as a K5.6 head at the same pressure, since flow equals K times the square root of pressure. That makes high storage densities reachable without very high pressures. See our guide to <a href=\"\/en\/sa\/media-center\/sprinkler-head-types-k-factor-temperature\/\">sprinkler head types and K-factor<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed703b3 elementor-widget elementor-widget-text-editor\" data-id=\"ed703b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>CMDA storage sprinkler vs ESFR<\/h2>\n<p>ESFR (Early Suppression Fast Response) works differently: it aims to suppress the fire with large drops and very high flow, and is designed on a fixed number of heads at a minimum pressure. CMDA is designed on density and area, and here the response is standard.<\/p>\n<ul><li><strong>ESFR:<\/strong> usually suitable where the ceiling, storage height and the standard&#8217;s limits allow it, and often reduces the need for in-rack sprinklers.<\/li><li><strong>CMDA such as FL-SR\/ST:<\/strong> more flexible with ceiling types and obstructions, but may need higher densities or in-rack sprinklers depending on commodity and height.<\/li><\/ul>\n<p>The choice is a design decision based on commodity, storage height and ceiling. For the bigger picture see <a href=\"\/en\/sa\/media-center\/warehouse-high-rack-storage-fire-protection-esfr\/\">fire protection for warehouses and logistics facilities<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ceecd elementor-widget elementor-widget-text-editor\" data-id=\"a7ceecd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FL-SR\/ST specifications from the datasheet<\/h2>\n<table><thead><tr><th>Item<\/th><th>V3403<\/th><th>V3407<\/th><\/tr><\/thead><tbody>\n<tr><td>Orientation<\/td><td>Upright<\/td><td>Pendent<\/td><\/tr>\n<tr><td>Type and response<\/td><td>CMDA, standard<\/td><td>CMDA, standard<\/td><\/tr>\n<tr><td>K-factor<\/td><td>11.2 (16.1 S.I.)<\/td><td>11.2 (16.1 S.I.)<\/td><\/tr>\n<tr><td>Connection<\/td><td>3\/4 in NPT, 20 mm BSPT, IGS<\/td><td>3\/4 in NPT, 20 mm BSPT, IGS<\/td><\/tr>\n<tr><td>Max working pressure<\/td><td>175 psi (1200 kPa)<\/td><td>175 psi (1200 kPa)<\/td><\/tr>\n<tr><td>Guard<\/td><td>V34\/V36<\/td><td>V34\/V36<\/td><\/tr>\n<\/tbody><\/table>\n<ul><li><strong>Factory test:<\/strong> 100% hydrostatic at 500 psi (34 bar).<\/li><li><strong>Minimum operating pressure:<\/strong> 7 psi (0.5 bar) for UL and FM.<\/li><li><strong>Materials:<\/strong> bronze deflector, load screw and pip cap, brass frame, PTFE coated beryllium nickel spring seal, 3.0 mm nominal glass bulb.<\/li><li><strong>Finishes:<\/strong> plain brass, chrome, white polyester, flat black and custom colours.<\/li><\/ul>\n<p>When pressure is in bar, the datasheet notes that the S.I. K-factor is multiplied by 10 (16.1 becomes 161), a point to watch in metric hydraulic calculations.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b516a3e elementor-widget elementor-widget-text-editor\" data-id=\"b516a3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Storage types Victaulic lists for this sprinkler<\/h2>\n<p>The performance section of the datasheet links each storage type to its NFPA reference and the matching FM Global data sheet:<\/p>\n<table><thead><tr><th>Storage type<\/th><th>NFPA<\/th><th>FM Data Sheet<\/th><\/tr><\/thead><tbody>\n<tr><td>Open frame single, double, multiple-row or portable racks, Class I-IV and Group A or B plastics<\/td><td>NFPA 13<\/td><td>2-0<\/td><\/tr>\n<tr><td>Solid pile or palletized, Class I-IV and Group A or B plastics<\/td><td>NFPA 13<\/td><td>2-0<\/td><\/tr>\n<tr><td>Idle pallets<\/td><td>NFPA 13<\/td><td>8-24<\/td><\/tr>\n<tr><td>Rubber tires<\/td><td>NFPA 13<\/td><td>8-3<\/td><\/tr>\n<tr><td>Rolled paper<\/td><td>NFPA 13<\/td><td>8-21<\/td><\/tr>\n<tr><td>Flammable liquids<\/td><td>NFPA 30<\/td><td>7-29<\/td><\/tr>\n<tr><td>Aerosols<\/td><td>NFPA 30B<\/td><td>7-31<\/td><\/tr>\n<tr><td>Automotive components in portable racks<\/td><td>NFPA 13 (control mode only)<\/td><td>N\/A<\/td><\/tr>\n<\/tbody><\/table>\n<p>The table tells you where to find the design criteria; it does not replace them. Density, area, maximum storage height and any in-rack heads come from the standard and the approved design. In Saudi Arabia the binding requirements are SBC 801 and Civil Defense, with NFPA and FM as technical references. For tyre warehouses see <a href=\"\/en\/sa\/media-center\/tyre-rubber-storage-warehouses-fire-protection\/\">tyre and rubber storage fire protection<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b338f8 elementor-widget elementor-widget-text-editor\" data-id=\"0b338f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Temperature ratings and IGS connection<\/h2>\n<p>The listing tables show 57, 68, 79, 93 and 141\u00b0C for both models under cULus and FM. In non air conditioned Saudi warehouses the temperature under a metal roof can rise sharply in summer, so the rating should be based on a realistic ambient value at the ceiling, not the default office choice.<\/p>\n<p>IGS is Victaulic&#8217;s installation-ready grooved sprinkler connection, installed with the V9 coupling using a 3\/16 hex bit. The datasheet refers to instructions I-V9 for installation and publication 10.65 for the coupling.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1d13cc elementor-widget elementor-widget-text-editor\" data-id=\"d1d13cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation and maintenance notes<\/h2>\n<ul><li>Depressurise and drain the system completely before installing, removing or adjusting any head, as Victaulic requires.<\/li><li>Use the correct wrench: V34 recessed, V34 open end, or the hex bit for V9.<\/li><li>In forklift aisles the V34\/V36 guard protects heads from impact.<\/li><li>Stock must keep the required clearance below the deflector per the standard; goods stacked close to the head spoil the spray pattern.<\/li><li>Inspect and test periodically to the adopted standard and Victaulic instructions I-40.<\/li><\/ul>\n<p>These points often come up in Civil Defense warehouse inspections. See <a href=\"\/en\/sa\/media-center\/warehouse-salamah-licence-fire-requirements\/\">Salamah licence for warehouses<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ceb5b5 elementor-widget elementor-widget-text-editor\" data-id=\"4ceb5b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK helps<\/h2>\n<p>AZEIDK supplies FL-SR\/ST sprinklers in both models with datasheets and listing tables for the submittal, reviews model, temperature and connection on the drawings, and can extend the work to <a href=\"\/en\/sa\/services\/installation-implementation\/\">installation<\/a>, testing and commissioning. See our <a href=\"\/en\/sa\/industries\/warehouses-logistics\/\">warehouses and logistics<\/a> page and <a href=\"\/en\/sa\/media-center\/victaulic-brand-sprinklers-saudi-arabia\/\">Victaulic in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb65cf0 elementor-widget elementor-widget-text-editor\" data-id=\"eb65cf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What does CMDA mean?<\/h3><\/summary><p>Control Mode Density Area: a fire control sprinkler whose system is designed for a set water density over a calculated design area.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the difference between V3403 and V3407?<\/h3><\/summary><p>V3403 is upright and sits above the pipe; V3407 is pendent and hangs below it. Both share K11.2, pressure rating and standard response.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the working pressure of the Victaulic K11.2 storage sprinkler?<\/h3><\/summary><p>Maximum 175 psi, UL\/FM minimum operating pressure 7 psi, and each head is factory tested at 500 psi.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a K11.2 sprinkler a replacement for ESFR?<\/h3><\/summary><p>Not directly. They are designed in different ways, and commodity, storage height, ceiling and the adopted standard decide which one applies.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can it protect idle pallets and tyres?<\/h3><\/summary><p>The datasheet lists these storage types with their reference standards, but density and allowable height come from the approved design.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What connection sizes are available?<\/h3><\/summary><p>3\/4 in NPT, 20 mm BSPT, or IGS grooved with the V9 coupling.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a409e8 elementor-widget elementor-widget-text-editor\" data-id=\"2a409e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>The Victaulic FL-SR\/ST K11.2 storage sprinkler is a CMDA option for warehouses, with V3403 upright and V3407 pendent. Its value shows when it is chosen from the commodity, storage height and ceiling temperature, using the datasheet&#8217;s application table as the starting point to the right standard.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dac329d elementor-widget elementor-widget-text-editor\" data-id=\"dac329d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Planning warehouse protection?<\/strong> Send the layout, commodity, storage height and roof type, and we will send suitable sprinklers and datasheets for your submittal. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8de87e3 elementor-widget elementor-widget-text-editor\" data-id=\"8de87e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"\/wp-content\/uploads\/2026\/07\/Victaulic-FireLock-FL-SRST-K11.2-Storage-Sprinklers-\u2013-V3403-and-V3407.pdf\" rel=\"noopener\" target=\"_blank\">Victaulic FireLock FL-SR\/ST K11.2, publication 44.51<\/a> (<a href=\"\/en\/brand\/victaulic\/\">AZEIDK brand page<\/a>) (Victaulic), and the AZEIDK <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-sr-st-k11-2-storage-sprinklers-v3403-and-v3407\/\">FL-SR\/ST product page<\/a><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>K11.2 storage sprinkler from Victaulic FL-SR\/ST: CMDA vs ESFR, V3403 and V3407 specs, storage types with their standards, temperatures and installation.<\/p>\n","protected":false},"author":0,"featured_media":28565,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-28598","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28598","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28598"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28598\/revisions"}],"predecessor-version":[{"id":28630,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28598\/revisions\/28630"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28565"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28598"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28598"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28598"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28598"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}