{"id":28596,"date":"2026-11-21T14:42:09","date_gmt":"2026-11-21T11:42:09","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T14:53:47","modified_gmt":"2026-11-21T11:53:47","slug":"ubw-125sul-globe-valve-sprinkler","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/ubw-125sul-globe-valve-sprinkler\/","title":{"rendered":"Globe Valve for Sprinkler Systems: United Brass Works 125SUL Bronze, Pressure, Sizes and Drain and Test Uses"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28596\" class=\"elementor elementor-28596 elementor-28595 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ca67c14 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"ca67c14\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3267879 elementor-widget elementor-widget-text-editor\" data-id=\"3267879\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>globe valve<\/strong> closes with a disc that moves straight onto a seat inside the body, and is used where small lines need tight shut-off and gradual flow control. In Saudi Arabia AZEIDK supplies the <a href=\"\/en\/sa\/products\/united-brass-works-model-125sul-globe-valve\/\">United Brass Works Model 125SUL globe valve<\/a>, a bronze valve UL listed for fire sprinkler service at 250 WOG, with threaded ends from 1\/2 to 2 in.<\/p>\n<p>This guide explains where globe valves are used in sprinkler systems, the 125SUL specifications and dimension table from the datasheet, how it compares with ball and gate valves, and what to check when ordering.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b572ef3 elementor-widget elementor-widget-text-editor\" data-id=\"b572ef3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>UBW 125SUL: bronze body, Buna-N soft disc, rising stem, integral seat, swivel disc holder.<\/li><li>UL listed for fire sprinkler service at 250 WOG; 200 WOG at 180\u00b0F (about 82\u00b0C) maximum.<\/li><li>Every valve is 100% pressure tested.<\/li><li>Threaded ends in 1\/2, 3\/4, 1, 1\u00bc, 1\u00bd and 2 in.<\/li><li>Contains lead; not intended for potable water systems.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-731f967 elementor-widget elementor-widget-text-editor\" data-id=\"731f967\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is a globe valve and how does it work?<\/h2>\n<p>In a globe valve, water changes direction inside the body and passes through the seat opening. Turning the handwheel lowers the stem and disc onto the seat to close. Because the gap between disc and seat changes gradually, flow can be controlled precisely, unlike a gate valve that is used fully open or fully closed.<\/p>\n<p>The trade-off is a higher pressure loss than a full port ball valve or gate valve, because of the change of direction. That is why globe valves serve small and auxiliary lines, not main control duty on large supply lines.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa27219 elementor-widget elementor-widget-text-editor\" data-id=\"aa27219\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Globe valve uses in sprinkler systems<\/h2>\n<p>According to the AZEIDK product page, the 125SUL is used for:<\/p>\n<ul><li><strong>Drain and test lines<\/strong> on sprinkler risers, where gradual opening avoids pressure shock.<\/li><li><strong>Alarm valve trim<\/strong>, the small lines around a wet alarm check valve.<\/li><li><strong>Inspector&#8217;s test connections<\/strong>, to simulate one open sprinkler and test the flow signal.<\/li><li><strong>Small side lines<\/strong> needing flow control or tight shut-off for routine maintenance without shutting down the main system.<\/li><\/ul>\n<p>See <a href=\"\/en\/sa\/media-center\/afc-acv-300-wet-alarm-check-valve\/\">AFC ACV-300 wet alarm check valve<\/a> for trim components and <a href=\"\/en\/sa\/media-center\/false-waterflow-alarm-sprinkler-retard\/\">false waterflow alarm fixes<\/a> for the role of flow testing.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8beee56 elementor-widget elementor-widget-text-editor\" data-id=\"8beee56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>UBW 125SUL globe valve specifications<\/h2>\n<ul><li><strong>Listing:<\/strong> UL listed for fire sprinkler service at 250 WOG.<\/li><li><strong>Temperature rating:<\/strong> 200 WOG at 180\u00b0F maximum.<\/li><li><strong>Testing:<\/strong> 100% pressure tested.<\/li><li><strong>Design:<\/strong> threaded ends, rising stem, integral seat, swivel disc holder, soft disc.<\/li><li><strong>Manufacturer warning:<\/strong> contains lead; not for potable water systems.<\/li><\/ul>\n<p>WOG means Water Oil Gas, the working pressure rating at normal temperature. 250 WOG therefore means 250 psi (about 17 bar) in sprinkler service, falling to 200 WOG at 180\u00b0F.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eec1bda elementor-widget elementor-widget-text-editor\" data-id=\"eec1bda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Materials from the datasheet<\/h2>\n<table><thead><tr><th>Part<\/th><th>Material<\/th><\/tr><\/thead><tbody>\n<tr><td>Body<\/td><td>Bronze<\/td><\/tr>\n<tr><td>Bonnet<\/td><td>Brass up to 1 in, bronze 1\u00bc to 2 in<\/td><\/tr>\n<tr><td>Stem and disc holder<\/td><td>Brass<\/td><\/tr>\n<tr><td>Disc<\/td><td>Buna-N<\/td><\/tr>\n<tr><td>Packing<\/td><td>Graphite, non-asbestos<\/td><\/tr>\n<tr><td>Packing nut<\/td><td>Brass<\/td><\/tr>\n<tr><td>Hand wheel<\/td><td>Zinc or ductile iron<\/td><\/tr>\n<tr><td>Hex nut<\/td><td>Steel<\/td><\/tr>\n<\/tbody><\/table>\n<p>The Buna-N disc against the integral seat gives tight shut-off with moderate effort, and the swivel holder lets the disc seat without rotating friction, reducing disc wear when test lines are opened and closed often.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d65de30 elementor-widget elementor-widget-text-editor\" data-id=\"d65de30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>125SUL globe valve dimension table<\/h2>\n<p>Dimensions in inches and shipping weight in pounds as in the datasheet; C is the height with the valve closed:<\/p>\n<table><thead><tr><th>Size (in)<\/th><th>A<\/th><th>B<\/th><th>C (closed)<\/th><th>Ship weight (lb)<\/th><\/tr><\/thead><tbody><tr><td>\u00bd<\/td><td>2.22<\/td><td>2.03<\/td><td>3.38<\/td><td>0.69<\/td><\/tr><tr><td>\u00be<\/td><td>2.47<\/td><td>2.38<\/td><td>3.50<\/td><td>0.94<\/td><\/tr><tr><td>1<\/td><td>2.97<\/td><td>2.75<\/td><td>4.25<\/td><td>1.76<\/td><\/tr><tr><td>1\u00bc<\/td><td>3.56<\/td><td>3.00<\/td><td>4.75<\/td><td>2.50<\/td><\/tr><tr><td>1\u00bd<\/td><td>4.06<\/td><td>3.72<\/td><td>5.50<\/td><td>3.26<\/td><\/tr><tr><td>2<\/td><td>4.69<\/td><td>3.72<\/td><td>5.50<\/td><td>5.32<\/td><\/tr><\/tbody><\/table>\n<p>Dimension C matters because the stem rises when the valve opens. Leave enough clearance above the handwheel in tight spaces such as valve rooms and trim cabinets.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa3e4de elementor-widget elementor-widget-text-editor\" data-id=\"fa3e4de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Globe valve, ball valve or gate valve?<\/h2>\n<ul><li><strong>Globe valve:<\/strong> gradual control and tight shut-off, higher pressure loss. Suited to drain, test and small lines.<\/li><li><strong>Ball valve:<\/strong> quarter turn, low loss in full port types, but fast operation can cause pressure shock in some uses.<\/li><li><strong>OS&amp;Y gate valve:<\/strong> used fully open as a control valve whose position shows from the exposed stem, the usual choice on supply lines.<\/li><\/ul>\n<p>We compared gate and ball valves in <a href=\"\/en\/sa\/media-center\/osy-gate-ball-valves-ubw-apollo-saudi\/\">OS&amp;Y gate valves and ball valves: UBW and Apollo<\/a>. Control valves that can shut off sprinklers usually need position supervision under the adopted standard; see <a href=\"\/en\/sa\/media-center\/potter-waterflow-tamper-switches-saudi\/\">Potter waterflow and supervisory switches<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34c6daf elementor-widget elementor-widget-text-editor\" data-id=\"34c6daf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Ordering and installation points<\/h2>\n<ul><li>Specify size and thread type to match the project&#8217;s other trim.<\/li><li>Do not use the 125SUL on potable water lines or lines shared with them, since the manufacturer states it contains lead.<\/li><li>Install with the flow direction marked on the body, as globe valves are designed for a set flow direction relative to the disc.<\/li><li>Use a suitable thread sealant and do not grip the body across from the end being tightened.<\/li><li>Open test line valves gradually to avoid shock.<\/li><\/ul>\n<p>Locations of drain and test valves remain the consultant&#8217;s responsibility under SBC 801 and Civil Defense requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-76f8bfc elementor-widget elementor-widget-text-editor\" data-id=\"76f8bfc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK helps<\/h2>\n<p>AZEIDK supplies the UBW 125SUL with its datasheet for the submittal, reviews small valve schedules and riser trim on the drawings, and can extend the work to <a href=\"\/en\/sa\/services\/installation-implementation\/\">installation<\/a>, testing, commissioning and maintenance contracts. The full network is under <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb3b2e6 elementor-widget elementor-widget-text-editor\" data-id=\"cb3b2e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is a globe valve?<\/h3><\/summary><p>A valve that closes with a disc moving straight onto a seat, allowing gradual flow control and tight shut-off, with more pressure loss than a ball valve.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is the 125SUL listed for sprinkler systems?<\/h3><\/summary><p>The datasheet states it is UL listed for fire sprinkler service at 250 WOG.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What does 250 WOG mean?<\/h3><\/summary><p>A working pressure rating for water, oil and gas at normal temperature, here 250 psi, falling to 200 WOG at 180\u00b0F.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What sizes does the 125SUL come in?<\/h3><\/summary><p>1\/2, 3\/4, 1, 1\u00bc, 1\u00bd and 2 in, threaded.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can the 125SUL be used for drinking water?<\/h3><\/summary><p>No. The manufacturer states it contains lead and is not intended for potable water systems.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a globe valve used as a main sprinkler control valve?<\/h3><\/summary><p>Usually not. Supply lines use indicating control valves such as OS&amp;Y or supervised butterfly valves; globe valves serve small, drain and test lines.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-699911c elementor-widget elementor-widget-text-editor\" data-id=\"699911c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>In a sprinkler system the globe valve is a control and tight shut-off tool for small lines, not a substitute for main control valves. The UBW 125SUL is a bronze, UL listed 250 WOG option from 1\/2 to 2 in, provided it is kept away from potable water and the rising stem is allowed for on site.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-724f353 elementor-widget elementor-widget-text-editor\" data-id=\"724f353\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need globe valves for your project?<\/strong> Send your small valve schedule or riser drawings, and we will send suitable sizes and the datasheet for your submittal. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4614525 elementor-widget elementor-widget-text-editor\" data-id=\"4614525\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"\/wp-content\/uploads\/2026\/11\/United-Brass-Works-Model-125SUL-Globe-Valve-Datasheet.pdf\" rel=\"noopener\" target=\"_blank\">United Brass Works Model 125SUL Globe Valve datasheet<\/a> (<a href=\"\/en\/brand\/united-brass-works\/\">AZEIDK brand page<\/a>) (United Brass Works), and the AZEIDK <a href=\"\/en\/sa\/products\/united-brass-works-model-125sul-globe-valve\/\">UBW 125SUL product page<\/a><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Globe valve for sprinkler systems: UBW 125SUL bronze, UL listed at 250 WOG, materials and dimension table, drain and test uses, and ball valve comparison.<\/p>\n","protected":false},"author":0,"featured_media":28563,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,329,322],"tags":[],"azeidk_region":[223],"class_list":["post-28596","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-operation-maintenance-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28596"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28596\/revisions"}],"predecessor-version":[{"id":28628,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28596\/revisions\/28628"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28563"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28596"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28596"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28596"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}