{"id":28590,"date":"2026-11-21T14:41:19","date_gmt":"2026-11-21T11:41:19","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T14:55:09","modified_gmt":"2026-11-21T11:55:09","slug":"shurjoint-rcv-riser-check-valve","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/shurjoint-rcv-riser-check-valve\/","title":{"rendered":"Riser Check Valve: Shurjoint RCV Grooved Check Valve for Wet Sprinkler Risers, Sizes and Installation"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28590\" class=\"elementor elementor-28590 elementor-28589 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f508203 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"f508203\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1651b81 elementor-widget elementor-widget-text-editor\" data-id=\"1651b81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>riser check valve<\/strong> lets water flow one way up a sprinkler riser and closes automatically when flow reverses, so the pressure above it is held. In Saudi Arabia AZEIDK supplies the <a href=\"\/en\/sa\/products\/shurjoint-rcv-grooved-riser-check-valve\/\">Shurjoint RCV grooved riser check valve<\/a>, a ductile iron, grooved end check valve designed for the risers of wet sprinkler systems.<\/p>\n<p>This guide covers how the RCV works, its size and dimension table from the Shurjoint catalogue, how it differs from a swing check and a wet alarm valve, and what to watch during installation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a0544a elementor-widget elementor-widget-text-editor\" data-id=\"4a0544a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>Shurjoint RCV: ductile iron, grooved end check valve for wet system risers.<\/li><li>Single clapper with dual springs for non-slam closing, streamlined body with low friction loss.<\/li><li>Installs vertically or horizontally; valves are tested to UL 312.<\/li><li>Working pressure in the catalogue table: 300 psi (20 bar) for 2\u00bd to 6 in.<\/li><li>Side port in NPT or BSP: 1\u00bc in up to 3 in, 2 in from 4 in upward.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1e8c39 elementor-widget elementor-widget-text-editor\" data-id=\"a1e8c39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is a riser check valve?<\/h2>\n<p>The riser is the vertical pipe feeding floors or sprinkler zones. When flow stops or supply pressure drops, the check valve stops water returning from the system to the main, so the riser stays full and pressurised. This matters where there is more than one supply, or where part of a system must be separated hydraulically from another by design.<\/p>\n<p>In the RCV a single clapper is assisted by two springs. The springs return the clapper to its seat as soon as flow falls away, before a strong reverse velocity builds, which reduces water hammer caused by a clapper slamming onto a returning water column.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-969817b elementor-widget elementor-widget-text-editor\" data-id=\"969817b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Shurjoint RCV catalogue data<\/h2>\n<ul><li><strong>Body:<\/strong> ductile iron with grooved ends, joined directly with grooved couplings.<\/li><li><strong>Closing:<\/strong> single clapper, dual springs, non-slam operation.<\/li><li><strong>Flow:<\/strong> streamlined body with low friction loss.<\/li><li><strong>Position:<\/strong> vertical or horizontal.<\/li><li><strong>Testing:<\/strong> valves tested to UL 312.<\/li><li><strong>Pressure:<\/strong> 300 psi (20 bar) in the dimension table, based on roll or cut grooved standard wall carbon steel pipe.<\/li><\/ul>\n<p>In the catalogue&#8217;s fire protection section, the RCV appears in the UL and FM approved pressure table at 300 psi UL and 300 psi FM for 2\u00bd to 6 in. For listing details the catalogue refers to Shurjoint Data Sheet B-42, which should go into the submittal with the catalogue page.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ac698c elementor-widget elementor-widget-text-editor\" data-id=\"2ac698c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Riser check valve RCV sizes and dimensions<\/h2>\n<p>Values from the RCV table in the Shurjoint catalogue, where A is end-to-end length and B the side dimension as drawn, all at 300 psi:<\/p>\n<table><thead><tr><th>Size (pipe O.D.)<\/th><th>A<\/th><th>B<\/th><th>Side port (NPT or BSP)<\/th><th>Weight<\/th><\/tr><\/thead><tbody><tr><td>2\u00bd in (73.0 mm)<\/td><td>190 mm<\/td><td>114 mm<\/td><td>1\u00bc in<\/td><td>4.98 kg<\/td><\/tr><tr><td>76.1 mm<\/td><td>190 mm<\/td><td>114 mm<\/td><td>1\u00bc in<\/td><td>5.13 kg<\/td><\/tr><tr><td>3 in (88.9 mm)<\/td><td>178 mm<\/td><td>114 mm<\/td><td>1\u00bc in<\/td><td>4.99 kg<\/td><\/tr><tr><td>4 in (114.3 mm)<\/td><td>216 mm<\/td><td>146 mm<\/td><td>2 in<\/td><td>8.49 kg<\/td><\/tr><tr><td>139.7 mm<\/td><td>330 mm<\/td><td>210 mm<\/td><td>2 in<\/td><td>23.34 kg<\/td><\/tr><tr><td>5 in (141.3 mm)<\/td><td>330 mm<\/td><td>210 mm<\/td><td>2 in<\/td><td>23.80 kg<\/td><\/tr><tr><td>165.1 mm<\/td><td>305 mm<\/td><td>210 mm<\/td><td>2 in<\/td><td>22.83 kg<\/td><\/tr><tr><td>6 in (168.3 mm)<\/td><td>305 mm<\/td><td>210 mm<\/td><td>2 in<\/td><td>23.10 kg<\/td><\/tr><\/tbody><\/table>\n<p>The table includes metric sizes (76.1, 139.7 and 165.1 mm) next to US sizes. They do not match standard 3, 5 and 6 in pipe, so the valve must match the actual outside diameter of the pipe supplied, or the joint will not seal. See <a href=\"\/en\/sa\/media-center\/grooved-piping-shurjoint-guide-saudi\/\">Shurjoint grooved couplings for fire systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9518276 elementor-widget elementor-widget-text-editor\" data-id=\"9518276\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>RCV, swing check or alarm valve?<\/h2>\n<ul><li><strong>Swing check valve:<\/strong> a clapper hinged on a pin that closes by its weight and reverse flow, common in pump rooms and mains. See <a href=\"\/en\/sa\/media-center\/afc-swing-check-valve-fire-network\/\">AFC swing check valves<\/a>.<\/li><li><strong>RCV riser check:<\/strong> spring assisted clapper, short streamlined body, vertical or horizontal, suited to risers where space is tight.<\/li><li><strong>Wet alarm check valve:<\/strong> also a check valve, but with alarm trim that signals when a sprinkler opens. See <a href=\"\/en\/sa\/media-center\/afc-acv-300-wet-alarm-check-valve\/\">AFC ACV-300 wet alarm check valve<\/a>.<\/li><\/ul>\n<p>The RCV has no alarm trim, so where it serves a zone riser, waterflow alarm usually comes from a flow switch on the line, such as the units in <a href=\"\/en\/sa\/media-center\/potter-waterflow-tamper-switches-saudi\/\">Potter waterflow and supervisory switches<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f90a294 elementor-widget elementor-widget-text-editor\" data-id=\"f90a294\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation notes<\/h2>\n<ul><li><strong>Flow arrow:<\/strong> install with the body arrow pointing from supply to system.<\/li><li><strong>Correct grooves:<\/strong> the 300 psi rating assumes standard wall pipe with grooves to specification; grooves too deep or narrow weaken the joint.<\/li><li><strong>Side port:<\/strong> used for drain or gauge connection per the design; state NPT or BSP in the order to match the project&#8217;s trim.<\/li><li><strong>Supervised control valve:<\/strong> risers usually have a control valve with a tamper switch upstream of the check valve, so the zone can be isolated for maintenance with a signal to the fire alarm panel.<\/li><li><strong>Testing:<\/strong> hydrostatically test the riser to the adopted standard before handover.<\/li><\/ul>\n<p>These are general site points. The detailed design and valve positions are set by the consultant under SBC 801 and Civil Defense requirements, with NFPA as a technical reference.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c1d509 elementor-widget elementor-widget-text-editor\" data-id=\"3c1d509\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When is the RCV a good fit?<\/h2>\n<p>In multi-storey buildings or projects with several sprinkler zones, a short valve that installs vertically and joins with the same coupling system as the rest of the network has clear value. Grooved ends save installation time compared with flanges, but the choice between RCV, swing check and alarm valve remains an engineering decision tied to the valve&#8217;s role on the drawing.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9c8cad elementor-widget elementor-widget-text-editor\" data-id=\"f9c8cad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK helps<\/h2>\n<p>AZEIDK supplies the Shurjoint RCV with catalogue pages and listing data for the submittal, checks sizes, pipe outside diameters and side port threads on the drawings, and can extend the work to <a href=\"\/en\/sa\/services\/installation-implementation\/\">installation<\/a> and testing. The full network is under <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9e81aa elementor-widget elementor-widget-text-editor\" data-id=\"d9e81aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is a riser check valve?<\/h3><\/summary><p>A valve that allows one-way flow up a sprinkler riser and closes on reverse flow, holding pressure above it.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the working pressure of the Shurjoint RCV?<\/h3><\/summary><p>300 psi (20 bar) in the catalogue table, and the UL and FM table lists 300 psi for 2\u00bd to 6 in.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can the RCV be installed horizontally?<\/h3><\/summary><p>Yes, the catalogue states vertical or horizontal installation.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What sizes are available?<\/h3><\/summary><p>2\u00bd to 6 in, plus metric 76.1, 139.7 and 165.1 mm per the catalogue table.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does an RCV replace a wet alarm valve?<\/h3><\/summary><p>No. The RCV has no alarm trim, while an alarm valve combines check and alarm functions. The design role decides.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Why does the RCV use two springs?<\/h3><\/summary><p>To return the clapper to its seat quickly as flow falls, so it closes without a hard slam.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b6f84b elementor-widget elementor-widget-text-editor\" data-id=\"1b6f84b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>The Shurjoint RCV riser check valve is a short grooved solution for wet system risers, with a spring assisted clapper and a 300 psi catalogue rating. Match the size to the real pipe outside diameter, specify the side port thread and include Data Sheet B-42 in the submittal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1cc47d elementor-widget elementor-widget-text-editor\" data-id=\"d1cc47d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need RCV valves for your project?<\/strong> Send riser sizes and pipe type, and we will send suitable sizes and catalogue pages for your submittal. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1595df6 elementor-widget elementor-widget-text-editor\" data-id=\"1595df6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"\/wp-content\/uploads\/2026\/11\/Shurjoint-Full-Line-Catalog.pdf\" rel=\"noopener\" target=\"_blank\">Shurjoint Full Line Catalog<\/a> (<a href=\"\/en\/brand\/shurjoint\/\">AZEIDK brand page<\/a>) (Shurjoint, section 4, Model RCV), and the AZEIDK <a href=\"\/en\/sa\/products\/shurjoint-rcv-grooved-riser-check-valve\/\">Shurjoint RCV product page<\/a><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Riser check valve Shurjoint RCV: dual spring clapper, 300 psi, size and dimension table, how it differs from swing checks and alarm valves, installation.<\/p>\n","protected":false},"author":0,"featured_media":28566,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-28590","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28590"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28590\/revisions"}],"predecessor-version":[{"id":28634,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28590\/revisions\/28634"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28566"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28590"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}