{"id":28102,"date":"2026-11-20T16:46:30","date_gmt":"2026-11-20T13:46:30","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T11:37:36","modified_gmt":"2026-11-21T08:37:36","slug":"utp-vs-ftp-network-cable","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/utp-vs-ftp-network-cable\/","title":{"rendered":"UTP vs FTP Cable: Unshielded vs Shielded Network Cable (STP, S\/FTP) and When You Need Each"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28102\" class=\"elementor elementor-28102 elementor-28101 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4045f66 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"4045f66\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9a27ea elementor-widget elementor-widget-text-editor\" data-id=\"f9a27ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>UTP vs FTP<\/strong> comes down to shielding. UTP is an unshielded network cable that relies on pair twisting alone to reject interference; it is lighter, cheaper and easier to install, and it is enough for most offices, villas and shops. FTP, S\/FTP and what the market loosely calls &#8220;STP&#8221; are shielded with foil or braid, and they earn their cost near strong electromagnetic interference or in sensitive 10 Gb links, provided the whole channel is shielded and properly bonded.<\/p>\n<p>The structured cabling and network products AZEIDK supplies are listed under <a href=\"\/en\/sa\/products\/?product_category=network-systems\">network systems<\/a>.<\/p>\n<p>This guide explains the codes printed on the cable, when shielding is worth it, and what it requires, with examples from the network cables AZEIDK supplies under <a href=\"\/en\/sa\/solutions\/network-communication-systems\/\">network and communication solutions<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5e72ca elementor-widget elementor-widget-text-editor\" data-id=\"b5e72ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>ISO\/IEC 11801 codes have two parts: before the slash is the overall screen, after it the pair screening. U = unscreened, F = foil, S = braid.<\/li><li>U\/UTP has no shielding; F\/UTP has an overall foil; U\/FTP has foil on each pair; S\/FTP has an overall braid and foil on each pair.<\/li><li>Shielded cable only works with shielded jacks, panels and patch cords and a continuous bond to ground.<\/li><li>UTP suits electrically quiet areas; shielding suits motors, generators, power panels and some 10GBase-T links.<\/li><li>Shielded cable costs more, is heavier and stiffer, and fills conduits faster.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0811887 elementor-widget elementor-widget-text-editor\" data-id=\"0811887\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What UTP, FTP and STP mean<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Code<\/th><th>Overall screen<\/th><th>Pair screen<\/th><th>Common market name<\/th><\/tr><\/thead><tbody>\n<tr><td>U\/UTP<\/td><td>None<\/td><td>None<\/td><td>UTP<\/td><\/tr>\n<tr><td>F\/UTP<\/td><td>Foil<\/td><td>None<\/td><td>FTP or STP<\/td><\/tr>\n<tr><td>U\/FTP<\/td><td>None<\/td><td>Foil per pair<\/td><td>FTP or STP<\/td><\/tr>\n<tr><td>F\/FTP<\/td><td>Foil<\/td><td>Foil per pair<\/td><td>FTP or STP<\/td><\/tr>\n<tr><td>S\/FTP<\/td><td>Braid<\/td><td>Foil per pair<\/td><td>SFTP or STP<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>&#8220;STP&#8221; is a generic trade term, so always ask for the full code on the datasheet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9d3868 elementor-widget elementor-widget-text-editor\" data-id=\"b9d3868\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>UTP vs FTP compared<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>UTP (U\/UTP)<\/th><th>Shielded (F\/UTP, U\/FTP, F\/FTP, S\/FTP)<\/th><\/tr><\/thead><tbody>\n<tr><td>Interference rejection<\/td><td>Twisting and balance only<\/td><td>Twisting plus a metal screen<\/td><\/tr>\n<tr><td>Grounding<\/td><td>Not needed<\/td><td>Continuous bonding of the whole channel<\/td><\/tr>\n<tr><td>Diameter and weight<\/td><td>Smaller, lighter<\/td><td>Larger, heavier, fills conduits faster<\/td><\/tr>\n<tr><td>Flexibility<\/td><td>Easier to pull<\/td><td>Stiffer, larger bend radius<\/td><\/tr>\n<tr><td>Cost<\/td><td>Lower<\/td><td>Higher for cable, jacks and labour<\/td><\/tr>\n<tr><td>Typical use<\/td><td>Offices, villas, shops, indoor cameras<\/td><td>Near strong EMI sources, dense 10 Gb links, data rooms<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-850cb62 elementor-widget elementor-widget-text-editor\" data-id=\"850cb62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When UTP is enough<\/h2>\n<p>Most office, shop and villa networks run well on good UTP routed away from power cables. Black Box recommends UTP for electrically quiet environments and notes it is the most widely used type. Examples from the AZEIDK range: <a href=\"\/en\/sa\/products\/belden-7965e-cat6-uutp-cable\/\">Belden 7965E<\/a> Cat6 U\/UTP, 250 MHz, four 23 AWG solid copper pairs with an X-Spline separator and PVC CPR Eca jacket; <a href=\"\/en\/sa\/products\/az-link-utp-cat6-cabld-305mtrs-23-awg-high-performancd\/\">AZ Link Cat6 UTP<\/a>, 305 m, 23 AWG; the <a href=\"\/en\/sa\/products\/corning-everon-v500u-cat6a-unshielded-rj45-jack\/\">Corning Everon V500U<\/a> unshielded Cat6A jack, tested for PoE up to 90 W (IEEE 802.3bt); and the <a href=\"\/en\/sa\/products\/legrand-lcs3-033770-cat6a-utp-24-port-patch-panel-1u\/\">Legrand LCS\u00b3 033770<\/a> 24-port Cat6A UTP panel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a820377 elementor-widget elementor-widget-text-editor\" data-id=\"a820377\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When you need FTP or S\/FTP<\/h2>\n<p>Black Box lists elevator motors, fluorescent lighting, generators and air conditioners among common noise sources, and notes shielding is increasingly used to limit alien crosstalk in 10 GbE runs. In practice that means generator, pump and switch rooms, lift rooms, factories with motors and drives, data rooms designed for 10GBase-T, and public buildings whose specifications call for shielded LSZH cable. Shielded options from AZEIDK: <a href=\"\/en\/sa\/products\/belden-10gxe02-cat6a-sftp-lszh-cable\/\">Belden 10GXE02<\/a> Cat6A enhanced S\/FTP, 625 MHz, Beldfoil on each pair plus a 30% tinned copper braid, LSZH, 10GBase-T; and <a href=\"\/en\/sa\/products\/legrand-lcs3-032799-cat6a-f-ftp-lszh-cable\/\">Legrand LCS\u00b3 032799<\/a> Cat6A F\/FTP LSZH, Euroclass Dca, on 500 m drums.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a45b867 elementor-widget elementor-widget-text-editor\" data-id=\"a45b867\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Shield the whole channel or not at all<\/h2>\n<p>The most common site mistake is shielded cable terminated on unshielded jacks, or a screen cut back at the jack. Black Box notes the metal screens must be grounded to cancel interference. So use shielded jacks from the same system (for example the Legrand 033775 STP connector set), a shielded panel such as Legrand 033772 STP, shielded patch cords at both ends, bond the panel and cabinet to the telecom ground per the manufacturer and project specification, and test and record every link at handover.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4284f16 elementor-widget elementor-widget-text-editor\" data-id=\"4284f16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Cameras, Wi-Fi and PoE<\/h2>\n<p>PoE does not in itself require shielded cable; the unshielded V500U jack is tested to 90 W. The route decides: indoor office cameras are fine on UTP, while cameras in a factory yard near motors or alongside long power runs benefit from shielding. For the category choice itself see <a href=\"\/en\/sa\/media-center\/cat6-vs-cat6a-network-cable\/\">Cat6 vs Cat6A<\/a>. For long camera runs see <a href=\"\/en\/sa\/media-center\/cctv-cable-coax-vs-cat6\/\">CCTV cable: coax vs Cat6<\/a>, and for cost drivers see <a href=\"\/en\/sa\/media-center\/network-cabling-installation-cost-saudi\/\">network cabling installation cost<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5084611 elementor-widget elementor-widget-text-editor\" data-id=\"5084611\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the difference between UTP and FTP cable?<\/h3><\/summary><p>UTP has no metal screen; FTP has foil around the cable or around each pair. Shielding reduces interference but needs bonding and shielded jacks.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What does STP mean?<\/h3><\/summary><p>A generic name for shielded cable. Specify the ISO\/IEC 11801 code, such as F\/UTP, U\/FTP or S\/FTP.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is shielded cable faster than UTP?<\/h3><\/summary><p>No. Speed depends on the category, such as Cat6 or Cat6A. Shielding only protects the signal.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is UTP fine for CCTV?<\/h3><\/summary><p>Yes for most indoor and office sites. Prefer shielded cable near motors, generators or long parallel power runs.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What if a shielded cable is not grounded?<\/h3><\/summary><p>The screen cannot do its job of cancelling interference, so the whole channel must be bonded as the manufacturer instructs.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3beddf elementor-widget elementor-widget-text-editor\" data-id=\"a3beddf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-related\">Related reading: <a href=\"\/en\/sa\/media-center\/wire-mesh-cable-tray-legrand-cablofil\/\">Wire Mesh Cable Tray from Legrand Cablofil<\/a> and <a href=\"\/en\/sa\/media-center\/wifi-7-access-point-saudi\/\">Wi-Fi 7 Access Points for Businesses in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f844b3 elementor-widget elementor-widget-text-editor\" data-id=\"8f844b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Choosing between UTP and FTP?<\/strong> Send us the drawings, network room locations and expected noise sources, and we will propose category, shielding, jacks and panels with datasheets. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c35975 elementor-widget elementor-widget-text-editor\" data-id=\"6c35975\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>Sources:<\/strong> <a href=\"https:\/\/www.flukenetworks.com\/knowledge-base\/dsx-cableanalyzer-series\/acronyms-cables-dsx-cableanalyzer\" rel=\"noopener\" target=\"_blank\">Acronyms for cables (Fluke Networks, ISO\/IEC 11801 designations)<\/a>; <a href=\"https:\/\/www.blackbox.com\/en-sa\/insights\/blogs\/tps\/2022\/01\/11\/cable-basics-shielded-vs-unshielded-cable\" rel=\"noopener\" target=\"_blank\">Cable basics: shielded vs unshielded cable (Black Box)<\/a>; AZEIDK product pages (Belden 7965E, Belden 10GXE02, Legrand LCS\u00b3 032799 and 033770, Corning Everon V500U, AZ Link Cat6 UTP)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>UTP vs FTP: what U\/UTP, F\/UTP, U\/FTP and S\/FTP mean, when unshielded network cable is enough, when shielding pays off, and bonding and jack rules.<\/p>\n","protected":false},"author":0,"featured_media":28055,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-28102","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28102"}],"version-history":[{"count":2,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28102\/revisions"}],"predecessor-version":[{"id":28421,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28102\/revisions\/28421"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28055"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28102"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28102"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28102"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}