{"id":28098,"date":"2026-11-20T16:46:30","date_gmt":"2026-11-20T13:46:30","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T11:31:00","modified_gmt":"2026-11-21T08:31:00","slug":"momah-warehouses-storage-requirements-fire","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/momah-warehouses-storage-requirements-fire\/","title":{"rendered":"MOMAH Warehouse Requirements in Saudi Arabia: Fire Safety Clauses and Civil Defense Approval Before Licensing"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28098\" class=\"elementor elementor-28098 elementor-28097 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-513a842 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"513a842\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e722b06 elementor-widget elementor-widget-text-editor\" data-id=\"e722b06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">The Ministry of Municipalities and Housing <strong>warehouse requirements<\/strong> govern how warehouses, stores and low and medium hazard self-storage units are licensed on the Balady platform. They make Civil Defense approval a condition before the licence is issued and refer every fire protection requirement to the Saudi Fire Protection Code, SBC 801.<\/p>\n<p>For the steps to obtain the <a href=\"\/en\/sa\/media-center\/salamah-certificate-civil-defense-guide\/\">Salamah certificate<\/a> from Civil Defense on the Salamah platform, see our guide; our page on <a href=\"\/en\/sa\/media-center\/saudi-civil-defense-requirements-buildings-facilities\/\">Saudi Civil Defense requirements<\/a> covers the general requirements for buildings and facilities.<\/p>\n<p>This article summarises the safety and fire clauses of the document as published on the Ministry website (Ministerial Decision 4600327053\/1 dated 8\/10\/1446 AH) and explains what an owner or tenant should prepare before applying. For fire fighting and fire alarm systems in warehouses and help with Civil Defense requirements, see AZEIDK&#8217;s <a href=\"\/en\/sa\/industries\/warehouses-logistics\/\">warehouses and logistics<\/a> page and the <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> service.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eba87a7 elementor-widget elementor-widget-text-editor\" data-id=\"eba87a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>The requirements cover low and medium hazard warehouses, stores and self-storage units, not high hazard warehouses.<\/li><li>Civil Defense approval is required before the municipal licence is issued, together with a valid commercial registration covering the activity.<\/li><li>The fire protection clause refers to the full SBC 801 requirements and sets no design figures of its own.<\/li><li>A mezzanine may grow from one third to one half of the floor area where an approved automatic suppression system and audible alarm are installed.<\/li><li>Worker housing inside the warehouse is prohibited, the guard room must be outside, and any open flame is banned.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f05d74 elementor-widget elementor-widget-text-editor\" data-id=\"0f05d74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What do the warehouse requirements cover?<\/h2>\n<p>The document applies to warehouses, stores and self-storage units. It classifies storage by hazard with reference to SBC 201, section 311:<\/p>\n<ul><li><strong>Medium hazard (S1):<\/strong> storage of materials such as cartons and plastics.<\/li><li><strong>Low hazard (S2):<\/strong> storage of non-combustible materials such as building materials, appliances and non-combustible raw materials.<\/li><\/ul>\n<p>High hazard warehouses that store or handle flammable, explosive, toxic or radioactive materials are outside its scope, and the document places them within the areas of the Saudi Authority for Industrial Cities and Technology Zones (MODON). Their Civil Defense licensing is covered in our article on <a href=\"\/en\/sa\/media-center\/hazardous-materials-storage-license-civil-defense\/\">hazardous materials storage licences<\/a>.<\/p>\n<p>The class also affects the site: S2 warehouses may be built on the plot boundary on two sides only, while S1 warehouses may not be built on the boundary on any side.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6230004 elementor-widget elementor-widget-text-editor\" data-id=\"6230004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Civil Defense approval before the Balady licence<\/h2>\n<p>Issuing, renewing, amending, suspending and cancelling the licence follow the Municipal Licensing Procedures Law and its executive regulation. The core licensing conditions are:<\/p>\n<ol><li>Civil Defense approval before the licence is issued.<\/li><li>A valid commercial registration that includes the activities to be licensed.<\/li><li>Approval of the supervising authority for the activity, where one exists.<\/li><li>Compliance with the spatial and municipal requirements in the document.<\/li><\/ol>\n<p>Operating before licensing, under a different activity or after expiry is prohibited, and a facility closed by the municipality may not reopen until the violation is corrected and the municipality agrees. Civil Defense licensing for warehouses on Salamah is covered in <a href=\"\/en\/sa\/media-center\/warehouse-salamah-licence-fire-requirements\/\">Salamah licence for warehouses<\/a>, and the municipal licence steps in <a href=\"\/en\/sa\/media-center\/balady-municipal-licence-renewal-safety\/\">Balady licence issue and renewal<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ab44e5 elementor-widget elementor-widget-text-editor\" data-id=\"4ab44e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire clauses in the warehouse requirements<\/h2>\n<p>The fire protection clause itself is short: refer to all requirements of the Saudi Fire Protection Code, SBC 801. Several other clauses are directly linked to fire safety:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Clause<\/th><th>What it says<\/th><th>What it means in practice<\/th><\/tr><\/thead><tbody><tr><td>Fire protection<\/td><td>Refer to all SBC 801 requirements<\/td><td>Sprinklers, alarm and extinguishers are designed to the code and occupancy<\/td><\/tr><tr><td>Mezzanine<\/td><td>Up to one third of the floor, or up to one half with an approved automatic suppression system and audible alarm<\/td><td>A larger mezzanine depends on approved suppression and alarm<\/td><\/tr><tr><td>Emergency exits<\/td><td>Provide exits required by Civil Defense rules; no equipment in them<\/td><td>No racks or raised or protruding equipment in exit paths<\/td><\/tr><tr><td>Fire appliance access<\/td><td>Enough space on site for fire appliances to manoeuvre, per the approved site plan<\/td><td>Considered in the site layout and loading areas<\/td><\/tr><tr><td>Ceilings<\/td><td>Fire resistant materials not affected by humidity<\/td><td>Checked when selecting roofing materials<\/td><\/tr><tr><td>Housing and flames<\/td><td>No worker housing inside, guard room outside, no open flame, gas or charcoal<\/td><td>No kitchens or stoves in storage areas<\/td><\/tr><tr><td>Lighting<\/td><td>Gas lighting prohibited inside and outside<\/td><td>Electric lighting to approved specifications<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Wall-mounted air conditioning units on storage buildings also need an external steel frame so they cannot fall outward during a fire, and offices and staff facilities must meet SBC 201 safety requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db4d5fc elementor-widget elementor-widget-text-editor\" data-id=\"db4d5fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What the requirements leave to SBC 801<\/h2>\n<p>The warehouse requirements do not say when sprinklers are required, which detectors to use or how many extinguishers to install. These follow from SBC 801 according to occupancy, area, storage height and commodity, and the engineering office checks them in the safety drawings. A sound sequence is:<\/p>\n<ul><li>Confirm the hazard class (S1 or S2), the goods and whether storage is racked or on the floor.<\/li><li>Check whether sprinklers are required, as explained in <a href=\"\/en\/sa\/media-center\/civil-defense-requirements-sprinkler-mandatory-sbc-801-saudi\/\">are sprinklers mandatory under SBC 801?<\/a><\/li><li>Select detection suited to high ceilings, see <a href=\"\/en\/sa\/media-center\/warehouse-smoke-detectors-beam-vs-point\/\">warehouse smoke detectors: beam or point<\/a>.<\/li><\/ul>\n<p>AZEIDK designs and installs <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a> and <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm systems<\/a> for warehouses to the code and authority requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0011611 elementor-widget elementor-widget-text-editor\" data-id=\"0011611\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Daily operation: extinguishers, evacuation plan and aisles<\/h2>\n<ul><li>Provide suitable numbers and types of fire extinguishers according to Civil Defense classifications and the operations carried out.<\/li><li>Post signs explaining the evacuation plan and make sure staff follow it in a fire or emergency.<\/li><li>Train all staff in safety and first aid and keep a first aid kit on site.<\/li><li>Do not store goods in aisles, external setbacks, roofs or areas not designated for storage.<\/li><li>Mark forklift routes on the floor, separated from pedestrian paths.<\/li><li>No smoking outside designated areas.<\/li><\/ul>\n<p>In self-storage facilities internal corridors between units must be at least 1.5 m wide and each unit between 4 and 24 m\u00b2. CCTV must be installed in line with the security camera law and its executive regulation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cc61d5 elementor-widget elementor-widget-text-editor\" data-id=\"6cc61d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes that delay a warehouse licence<\/h2>\n<ul><li>Storing goods that change the hazard class after the design was approved, such as adding plastics to a warehouse designed as S2.<\/li><li>Adding or enlarging a mezzanine without approved automatic suppression and audible alarm.<\/li><li>Blocking an emergency exit with racks or equipment, or using aisles and setbacks for temporary storage.<\/li><li>Keeping a guard room or worker housing inside the warehouse building.<\/li><li>Applying before the fire systems are installed and tested, which delays Civil Defense approval.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-803daf8 elementor-widget elementor-widget-text-editor\" data-id=\"803daf8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Checklist before applying for the licence<\/h2>\n<ol><li>Confirm the stored goods place the warehouse in S1 or S2, not high hazard.<\/li><li>Approve the site plan with fire appliance access and emergency exits.<\/li><li>Have the fire systems designed to SBC 801 by a qualified engineering office, then installed and tested before requesting Civil Defense approval.<\/li><li>Install extinguishers and evacuation plan signs, see <a href=\"\/en\/sa\/media-center\/fire-evacuation-plan-board\/\">fire evacuation plan board<\/a>.<\/li><li>Remove any housing or flame source from inside the warehouse.<\/li><li>With Civil Defense approval in hand, apply on Balady with a valid commercial registration.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33f8223 elementor-widget elementor-widget-text-editor\" data-id=\"33f8223\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Do the warehouse requirements need Civil Defense approval?<\/h3><\/summary><p>Yes. Civil Defense approval must be obtained before the municipal licence is issued.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Do they say when sprinklers are required?<\/h3><\/summary><p>No. They refer fire protection to SBC 801, which sets this by occupancy, area and storage arrangement.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the difference between S1 and S2 warehouses?<\/h3><\/summary><p>S1 is medium hazard, for materials such as cartons and plastics. S2 is low hazard, for non-combustible materials such as building materials, by reference to SBC 201.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can workers live inside a warehouse?<\/h3><\/summary><p>No. Worker housing inside warehouses is prohibited and the guard room must be outside.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Do the requirements cover hazardous materials warehouses?<\/h3><\/summary><p>No. High hazard warehouses are excluded and are placed within MODON areas.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can a warehouse mezzanine be enlarged?<\/h3><\/summary><p>Yes, from one third to one half of the floor area where the floor has an approved automatic suppression system and audible alarm.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6f83d15 elementor-widget elementor-widget-text-editor\" data-id=\"6f83d15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-related\">Related reading: <a href=\"\/en\/sa\/media-center\/event-sites-seasonal-markets-requirements-fire\/\">Temporary Event Requirements in Saudi Arabia<\/a>, <a href=\"\/en\/sa\/media-center\/shisha-cafes-fire-safety-requirements-saudi\/\">Shisha Cafe Safety Requirements in Saudi Arabia<\/a> and <a href=\"\/en\/sa\/media-center\/kids-indoor-play-centers-fire-safety\/\">Indoor Kids Play Centers Fire Safety in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a7ed14 elementor-widget elementor-widget-text-editor\" data-id=\"5a7ed14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing a warehouse for licensing?<\/strong> Send us the area, goods and storage method, and AZEIDK will review the fire systems needed, install and test them and follow up the Civil Defense requirements. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ca48db elementor-widget elementor-widget-text-editor\" data-id=\"3ca48db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>Sources:<\/strong> <a href=\"https:\/\/momah.gov.sa\/sites\/default\/files\/2025-04\/ashtratat%20almstwd%60at%20walmkhazn.pdf\" rel=\"noopener\" target=\"_blank\">Warehouse and Storage Requirements (Arabic PDF)<\/a> (Ministry of Municipalities and Housing, 2025)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Saudi warehouse requirements from MOMAH: Civil Defense approval before licensing, S1 and S2 classes, mezzanines with suppression, exits and SBC 801.<\/p>\n","protected":false},"author":0,"featured_media":28068,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-28098","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28098","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28098"}],"version-history":[{"count":2,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28098\/revisions"}],"predecessor-version":[{"id":28269,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28098\/revisions\/28269"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28068"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28098"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28098"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28098"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28098"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}