{"id":28093,"date":"2026-11-20T16:46:30","date_gmt":"2026-11-20T13:46:30","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-20T16:46:32","modified_gmt":"2026-11-20T13:46:32","slug":"em-vs-mifare-access-card","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/em-vs-mifare-access-card\/","title":{"rendered":"EM vs MIFARE Access Cards: 125 kHz vs 13.56 MHz and When to Use Each"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28093\" class=\"elementor elementor-28093 elementor-28092 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442185c e-con-full az-el-article e-flex e-con e-parent\" data-id=\"442185c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e90dab elementor-widget elementor-widget-text-editor\" data-id=\"2e90dab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>EM vs MIFARE cards:<\/strong> an EM card (often listed as an ID card) runs at 125 kHz and carries a fixed number that the reader reads without encryption, so it is cheap but easy to copy. A MIFARE card (often listed as an IC card) runs at 13.56 MHz and has memory and encryption, with security depending on the family: MIFARE Classic is the oldest and weakest, while MIFARE Plus and DESFire use AES for higher-security sites. A card only works with a reader that supports its frequency.<\/p>\n<p>This guide explains the practical difference and how to read the card type on a datasheet, using <a href=\"\/en\/sa\/solutions\/security-surveillance-systems\/\">access control and time attendance devices<\/a> AZEIDK supplies from Dahua, Hikvision and ZKTeco.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262caf5 elementor-widget elementor-widget-text-editor\" data-id=\"262caf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>EM \/ ID card: 125 kHz, fixed number, no encryption, described by Allegion as &#8220;easily duplicated&#8221;.<\/li><li>MIFARE \/ IC card: 13.56 MHz, memory and encryption, security depends on the family.<\/li><li>MIFARE Classic uses a 48-bit key, and NXP does not recommend it for security-relevant applications.<\/li><li>MIFARE Plus and DESFire (EV1, EV2, EV3) use AES.<\/li><li>Check reader support before buying cards, or use a dual-frequency reader such as the Dahua ASR2101A-ME.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d238b63 elementor-widget elementor-widget-text-editor\" data-id=\"d238b63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>EM vs MIFARE at a glance<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>EM card (125 kHz)<\/th><th>MIFARE card (13.56 MHz)<\/th><\/tr><\/thead><tbody>\n<tr><td>Datasheet name<\/td><td>ID card, EM card, proximity<\/td><td>IC card, MIFARE, smart card<\/td><\/tr>\n<tr><td>Data<\/td><td>ID number stored unencrypted<\/td><td>Memory protected by keys (except Ultralight)<\/td><\/tr>\n<tr><td>Encryption<\/td><td>None<\/td><td>Classic 48-bit key; Plus and DESFire AES<\/td><\/tr>\n<tr><td>Cloning<\/td><td>Easily duplicated (Allegion)<\/td><td>Classic has published attacks; DESFire far harder<\/td><\/tr>\n<tr><td>Cost<\/td><td>Lowest<\/td><td>Higher, more for Plus and DESFire<\/td><\/tr>\n<tr><td>Typical use<\/td><td>Time attendance, low-risk doors<\/td><td>Offices and compounds; DESFire for sensitive areas<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab9ee52 elementor-widget elementor-widget-text-editor\" data-id=\"ab9ee52\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>125 kHz EM cards<\/h2>\n<p>Allegion (Schlage) says 125 kHz proximity credentials suit facilities with less demanding security needs, store data unencrypted and are easily duplicated, while smart credentials are difficult to duplicate. EM is fine for time attendance, low-risk staff doors and existing EM systems. AZEIDK examples: the <a href=\"\/en\/sa\/products\/zkteco-sf300\/\">ZKTeco SF300<\/a> with optional EM or IC cards (5,000 cards), and the Dahua ASI1212F-D, which reads 125 kHz ID cards (a discontinued model listed for existing systems).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fe02fd elementor-widget elementor-widget-text-editor\" data-id=\"3fe02fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>MIFARE families: Classic, Plus or DESFire<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Family<\/th><th>Protection<\/th><th>Note<\/th><\/tr><\/thead><tbody>\n<tr><td>MIFARE Classic<\/td><td>48-bit key<\/td><td>Successful attacks published; NXP recommends upgrading<\/td><\/tr>\n<tr><td>MIFARE Plus<\/td><td>AES-128<\/td><td>Higher security with AES-capable readers<\/td><\/tr>\n<tr><td>MIFARE DESFire (EV1, EV2, EV3)<\/td><td>AES<\/td><td>Highest-security MIFARE family per CDVI<\/td><\/tr>\n<tr><td>MIFARE Ultralight<\/td><td>No cryptographic features<\/td><td>512-bit memory, simple uses<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>In a statement dated 12 October 2015, NXP said it does not recommend designing MIFARE Classic into any security-relevant application and recommended upgrading existing systems to MIFARE Plus or DESFire. Salto notes that modern cloning devices make it easier to copy non-secure credentials including MIFARE Classic and suggests DESFire for new high-security installations. Many readers list only MIFARE Classic 1K on their datasheet, so if you want DESFire, choose readers and controllers for it from the start.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33dc521 elementor-widget elementor-widget-text-editor\" data-id=\"33dc521\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Reading the card type on a datasheet<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Device<\/th><th>Card type per datasheet<\/th><th>Notes<\/th><\/tr><\/thead><tbody>\n<tr><td><a href=\"\/en\/sa\/products\/dahua-asr2101a-me-access-reader\/\">Dahua ASR2101A-ME<\/a><\/td><td>MIFARE Classic 1K 13.56 MHz and ID 125 kHz<\/td><td>Touch keypad, 0 to 5 cm, RS-485 and Wiegand, IP66<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/zkteco-f22\/\">ZKTeco F22<\/a><\/td><td>ID or MIFARE (optional)<\/td><td>3,000 fingerprints, 5,000 cards, Wi-Fi<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/zkteco-sf300\/\">ZKTeco SF300<\/a><\/td><td>EM or IC (optional)<\/td><td>1,500 fingerprints, 5,000 cards<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/hikvision-ds-k1t320efwx-value-series-face-access-terminal\/\">Hikvision DS-K1T321MFWX<\/a><\/td><td>M1 card<\/td><td>Face, fingerprint, card and PIN; 3,000 cards<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/dahua-asi1212f-asi1212f-d-access-standalone\/\">Dahua ASI1212F \/ -D<\/a><\/td><td>IC 13.56 MHz or ID 125 kHz<\/td><td>Discontinued, for existing systems<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>&#8220;Optional&#8221; means the card type is chosen at order, so state it on the purchase order. The <a href=\"\/en\/sa\/products\/hikvision-ds-k2801-value-series-card-access-contoller\/\">Hikvision DS-K2801<\/a> single-door controller takes two Wiegand readers (W26\/W34) with a series capacity of 10,000 cards, so readers can be changed to 13.56 MHz while keeping the controller, provided the Wiegand format matches.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f24f869 elementor-widget elementor-widget-text-editor\" data-id=\"f24f869\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Moving from EM to MIFARE<\/h2>\n<p>Install dual-frequency readers first, issue new cards in phases and delete old ones after each phase. Allegion suggests multi-technology credentials that carry both 125 kHz and 13.56 MHz. For high-risk doors add a second factor such as PIN, fingerprint or face. See also <a href=\"\/en\/sa\/media-center\/zkteco-inbio-c3-access-control-panel\/\">ZKTeco InBio and C3 panels<\/a> and <a href=\"\/en\/sa\/media-center\/access-control-system-cost-door-saudi\/\">access control system cost<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6df2fb2 elementor-widget elementor-widget-text-editor\" data-id=\"6df2fb2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the difference between EM and MIFARE cards?<\/h3><\/summary><p>EM runs at 125 kHz with an unencrypted fixed number; MIFARE runs at 13.56 MHz with memory and encryption and is harder to copy, especially Plus and DESFire.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can an EM reader read MIFARE cards?<\/h3><\/summary><p>No, unless it is dual-frequency like the Dahua ASR2101A-ME.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What do IC card and ID card mean?<\/h3><\/summary><p>On Dahua datasheets, an IC card is 13.56 MHz and an ID card is 125 kHz.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is MIFARE Classic secure?<\/h3><\/summary><p>Better than EM, but NXP does not recommend it for security-relevant applications and recommends MIFARE Plus or DESFire.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can one card do attendance and doors?<\/h3><\/summary><p>Yes, if both devices support the same card type and the card is enrolled in both or managed from one software.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0f3cf0 elementor-widget elementor-widget-text-editor\" data-id=\"b0f3cf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Not sure which card to use?<\/strong> Send us your current reader models and the number of staff and doors, and we will propose the card and reader with datasheets. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d9283b elementor-widget elementor-widget-text-editor\" data-id=\"0d9283b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>Sources:<\/strong> <a href=\"https:\/\/www.mifare.net\/en\/security-statement-on-crypto1-implementations\/\" rel=\"noopener\" target=\"_blank\">Security Statement on Crypto1 Implementations (NXP, 12 Oct 2015)<\/a>; <a href=\"https:\/\/www.cdvi.co.uk\/learn-about-access-control\/what-is-access-control\/understanding-mifare-credentials\/\" rel=\"noopener\" target=\"_blank\">Understanding MIFARE credentials (CDVI)<\/a>; <a href=\"https:\/\/allegion.ca\/en\/schlage\/lps\/125-khz-proximity-credentials.html\" rel=\"noopener\" target=\"_blank\">125 kHz proximity credentials (Allegion \/ Schlage)<\/a>; <a href=\"https:\/\/saltosystems.com\/sites\/default\/files\/2024-11\/RFID%20Credentials%20Security%20Advisory-BG.pdf\" rel=\"noopener\" target=\"_blank\">RFID Credentials Security Advisory (Salto Systems)<\/a>; AZEIDK product pages<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>EM vs MIFARE access cards: 125 kHz vs 13.56 MHz, encryption and cloning, MIFARE Classic vs Plus and DESFire, and how to read the card type on a datasheet.<\/p>\n","protected":false},"author":0,"featured_media":28053,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-28093","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28093","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28093"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28093\/revisions"}],"predecessor-version":[{"id":28104,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28093\/revisions\/28104"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28053"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28093"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28093"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28093"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28093"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}