{"id":28020,"date":"2026-11-20T16:39:27","date_gmt":"2026-11-20T13:39:27","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-20T16:39:35","modified_gmt":"2026-11-20T13:39:35","slug":"paint-factory-fire-protection","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/paint-factory-fire-protection\/","title":{"rendered":"Paint Factory Fire Protection: Mixing Rooms, Solvent Stores and Foam Suppression"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28020\" class=\"elementor elementor-28020 elementor-28019 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-00f5c25 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"00f5c25\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-222c188 elementor-widget elementor-widget-text-editor\" data-id=\"222c188\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Paint factory fire protection<\/strong> starts from one fact: the plant handles large quantities of solvents and flammable liquids every day, in mixing tanks, transfer lines, the filling area and the raw material and finished goods stores. A fire here is a liquid fire that floats and spreads, water alone will not put it out, and a static spark during filling can be what starts it.<\/p>\n<p>This guide covers the hazard areas in a paint plant, why foam is the main extinguishing method, and which detection suits each area, within AZEIDK&#8217;s <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a> and <a href=\"\/en\/sa\/solutions\/special-fire-suppression-systems\/\">special fire suppression systems<\/a> for the <a href=\"\/en\/sa\/industries\/industrial-facilities\/\">industrial facilities<\/a> sector.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8d545d elementor-widget elementor-widget-text-editor\" data-id=\"b8d545d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>The highest-risk areas are mixing rooms, the filling area, the solvent store and external storage tanks.<\/li><li>Solvent fires are flammable liquid fires, fought mainly with foam that seals the liquid surface from oxygen.<\/li><li>Static electricity during liquid transfer and filling is a known ignition source, controlled by bonding and grounding.<\/li><li>Areas classified as hazardous need explosion-proof detectors and devices certified for the zone.<\/li><li>In Saudi Arabia SBC 801 and the competent authority&#8217;s requirements are binding, and NFPA 30 is the technical reference for flammable liquid storage and processing.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b29418 elementor-widget elementor-widget-text-editor\" data-id=\"1b29418\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where is the risk in a paint factory?<\/h2>\n<p><strong>Mixing and grinding rooms:<\/strong> tanks are opened and solvents and pigments added, creating flammable vapour around openings, next to mixer and mill motors.<\/p>\n<p><strong>Filling area:<\/strong> paint moves quickly from tanks into cans and drums, the point where static builds up most.<\/p>\n<p><strong>Solvent and raw material store:<\/strong> drums, cans and sometimes IBC totes of flammable liquids, in quantities that make any fire large from the start.<\/p>\n<p><strong>Finished goods store:<\/strong> sealed paint cans on racks, a lower hazard than solvents but still needing careful classification by paint type (water-based or solvent-based).<\/p>\n<p><strong>External tanks and unloading:<\/strong> solvents received from tankers and stored in tanks. Spacing and protection are covered in our article on <a href=\"\/en\/sa\/media-center\/nfpa-30-flammable-liquids-storage-tank-spacing\/\">NFPA 30 flammable liquids storage<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-418119e elementor-widget elementor-widget-text-editor\" data-id=\"418119e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Static electricity: the invisible cause<\/h2>\n<p>WorkSafeBC, the occupational safety authority in British Columbia, warned in a January 2015 risk advisory that paint and solvent plants face fire and explosion risk from static electricity, generated by friction as liquids move through equipment or are transferred between non-conductive containers. It links the risk to missing bonding and grounding of production equipment, requires metal containers to be bonded or grounded during transfer, and lists measures for large plastic containers such as limiting flow velocity and free fall.<\/p>\n<p>These are operating controls owned by the plant, but they are a core part of any protection plan. A good suppression system is not enough if the ignition source repeats every day at the filling line.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18483ca elementor-widget elementor-widget-text-editor\" data-id=\"18483ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Paint factory fire protection with foam<\/h2>\n<p>A solvent fire floats on water and spreads with it, so aqueous film-forming foam (AFFF) and similar concentrates are the main tool: they blanket the liquid surface, cut off oxygen and cool it. How foam is applied depends on the area:<\/p>\n<ul><li>Foam-water sprinklers or foam flooding over mixing, filling and solvent storage areas, per the design.<\/li><li>A bladder foam tank with a ratio controller to set the concentration.<\/li><li>Foam monitors for external tank and unloading areas.<\/li><li>Foam and water hose cabinets and foam extinguishers near work points.<\/li><\/ul>\n<p>AZEIDK supplies <a href=\"\/en\/sa\/products\/safe-guard-3-aqueous-film-forming-foam-200-l\/\">Safe Guard 3% AFFF foam concentrate<\/a>, <a href=\"\/en\/sa\/products\/sffeco-foam-bladder-tank\/\">SFFECO foam bladder tanks<\/a> and <a href=\"\/en\/sa\/products\/sffeco-foam-monitors\/\">SFFECO foam monitors<\/a>. System types are covered in <a href=\"\/en\/sa\/media-center\/foam-fire-suppression-systems\/\">foam fire suppression systems for industrial facilities<\/a>. Foam type, concentration and application rate depend on the liquids actually used and the foam datasheet, because some polar solvents such as alcohols need a foam rated for them.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aee24e elementor-widget elementor-widget-text-editor\" data-id=\"2aee24e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Detection and alarms in hazardous areas<\/h2>\n<p>Where flammable vapour may be present, detectors, call points and sounders must be explosion-proof, certified for the zone classification set by the plant. Triple infrared (IR3) flame detectors suit liquid fires because they respond to the flame directly without waiting for smoke. AZEIDK supplies the <a href=\"\/en\/sa\/products\/explosion-proof-triple-infrared-flame-detector-sfp-ir3-exd\/\">SFP IR3-EXD explosion-proof flame detector<\/a>; see also our articles on <a href=\"\/en\/sa\/media-center\/explosion-proof-smoke-detector-atex-zones\/\">explosion-proof smoke detectors<\/a> and <a href=\"\/en\/sa\/media-center\/flame-detectors-industrial\/\">industrial flame detectors<\/a>.<\/p>\n<p>If the plant wants vapour leak detection in the same system as fire, it is designed as an integrated fire and gas system, as described in <a href=\"\/en\/sa\/media-center\/fire-and-gas-system-industrial\/\">fire and gas systems in industrial facilities<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7b5a6 elementor-widget elementor-widget-text-editor\" data-id=\"fa7b5a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Area-by-area summary<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Area<\/th><th>Main hazard<\/th><th>Suggested detection<\/th><th>Suggested suppression<\/th><\/tr><\/thead><tbody>\n<tr><td>Mixing and grinding<\/td><td>Solvent vapour at openings<\/td><td>Explosion-proof flame detectors<\/td><td>Foam-water per design<\/td><\/tr>\n<tr><td>Filling area<\/td><td>Static and spills<\/td><td>Explosion-proof flame detectors<\/td><td>Foam-water, foam extinguishers<\/td><\/tr>\n<tr><td>Solvent store<\/td><td>Large flammable liquid load<\/td><td>Detectors suited to the zone<\/td><td>Foam-water sprinklers or foam flooding<\/td><\/tr>\n<tr><td>Finished goods store<\/td><td>Cans on racks<\/td><td>Smoke or beam detectors<\/td><td>Sprinklers per paint classification<\/td><\/tr>\n<tr><td>Tanks and unloading<\/td><td>Spills, liquid surface fire<\/td><td>Flame detectors<\/td><td>Foam monitors and hydrants<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e534ebe elementor-widget elementor-widget-text-editor\" data-id=\"e534ebe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Maintenance: foam does not stay ready on its own<\/h2>\n<p>A foam system untested since installation may not deliver the right concentration when needed. Foam concentrate has a shelf life and is affected by heat, proportioners and valves need regular operation, and explosion-proof detectors need inspection that does not open the enclosure in a way that voids its certification. Foam systems therefore belong in the maintenance contract with defined tests, covered by AZEIDK&#8217;s <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive maintenance<\/a> service.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a755983 elementor-widget elementor-widget-text-editor\" data-id=\"a755983\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Licensing and the competent authority<\/h2>\n<p>Storing hazardous materials requires a specific Civil Defense licence, explained in <a href=\"\/en\/sa\/media-center\/hazardous-materials-storage-license-civil-defense\/\">hazardous materials storage licence<\/a>. Depending on its classification, the plant may fall under Civil Defense or the High Commission for Industrial Security. AZEIDK prepares system requirements through its <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> service.<\/p>\n<p>Spray booths that apply paint in manufacturing or vehicle workshops follow a different standard, covered in <a href=\"\/en\/sa\/media-center\/paint-booth-fire-protection-nfpa-33\/\">paint booth fire protection<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d986dde elementor-widget elementor-widget-text-editor\" data-id=\"d986dde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Are water sprinklers enough for a paint factory?<\/h3><\/summary><p>Not in solvent areas, because a liquid fire floats on water. Foam or foam-water systems are used there, while water sprinklers may suit other areas depending on classification.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which foam suits paint plants?<\/h3><\/summary><p>AFFF is commonly used for hydrocarbon solvent fires, while polar solvents such as alcohols need a foam rated for them. Type and concentration are set once the liquids in use are known.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Why do fires recur at paint filling lines?<\/h3><\/summary><p>Liquid movement and free fall into containers generate static. Bonding, grounding and controlled flow rates greatly reduce the risk.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Do I need explosion-proof detectors throughout the plant?<\/h3><\/summary><p>No, only in areas classified as hazardous because of vapour. The plant sets the zone classification and devices are chosen with certification for each zone.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does AZEIDK supply foam and foam system equipment?<\/h3><\/summary><p>Yes. AZEIDK supplies Safe Guard foam and SFFECO bladder tanks and foam monitors, and installs fire fighting systems after design review.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dca7783 elementor-widget elementor-widget-text-editor\" data-id=\"dca7783\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>A paint factory needs protection built around the liquids it uses: the right foam in solvent areas, explosion-proof flame detection where vapour exists, and grounding procedures that stop the spark in the first place. Together these matter more than any single system.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-508b399 elementor-widget elementor-widget-text-editor\" data-id=\"508b399\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Reviewing a paint plant or equipping a new one?<\/strong> Send us the plant layout, the solvents used and stored quantities, and we will review the right foam and detection systems with you. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14c2817 elementor-widget elementor-widget-text-editor\" data-id=\"14c2817\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.worksafebc.com\/en\/resources\/health-safety\/risk-advisory\/explosion-or-fire-in-paint-or-solvent-manufacturing-due-to-static-electricity?lang=en\" rel=\"noopener\" target=\"_blank\">Explosion or fire in paint or solvent manufacturing due to static electricity, RA 2015-07<\/a> (WorkSafeBC, January 2015)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Paint factory fire protection in Saudi Arabia: mixing, filling and solvent store hazards, static electricity, foam suppression and explosion-proof detection.<\/p>\n","protected":false},"author":0,"featured_media":27986,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-28020","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28020","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28020"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28020\/revisions"}],"predecessor-version":[{"id":28036,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28020\/revisions\/28036"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/27986"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28020"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28020"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28020"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}