{"id":28002,"date":"2026-11-20T16:35:47","date_gmt":"2026-11-20T13:35:47","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T11:31:07","modified_gmt":"2026-11-21T08:31:07","slug":"shisha-cafes-fire-safety-requirements-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/shisha-cafes-fire-safety-requirements-saudi\/","title":{"rendered":"Shisha Cafe Safety Requirements in Saudi Arabia: Charcoal, Ventilation, Extinguishers and Fire Alarm"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28002\" class=\"elementor elementor-28002 elementor-28001 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23865ea e-con-full az-el-article e-flex e-con e-parent\" data-id=\"23865ea\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e068e74 elementor-widget elementor-widget-text-editor\" data-id=\"e068e74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Shisha cafe safety requirements<\/strong> in Saudi Arabia start with the &#8220;Requirements for Providing Tobacco Products&#8221; issued by the Ministry of Municipalities and Housing in 1446 AH. The document refers back to the Saudi Fire Code (SBC 801) and adds specific rules for the charcoal burner room, charcoal storage, the chimney, ventilation and security cameras. The real fire risk in a shisha lounge is not the seating area. It is the room where charcoal is lit and the place where it is stored.<\/p>\n<p>For the steps to obtain the <a href=\"\/en\/sa\/media-center\/salamah-certificate-civil-defense-guide\/\">Salamah certificate<\/a> from Civil Defense on the Salamah platform, see our guide; our page on <a href=\"\/en\/sa\/media-center\/saudi-civil-defense-requirements-buildings-facilities\/\">Saudi Civil Defense requirements<\/a> covers the general requirements for buildings and facilities.<\/p>\n<p>This article sets out what the requirements actually say, where fires usually start in a shisha cafe, which <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguishers<\/a> suit each area, and how to choose a <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm system<\/a> for a space that is full of smoke during every opening hour. It complements our <a href=\"\/en\/sa\/industries\/restaurants-commercial-kitchens\/\">restaurants and commercial kitchens<\/a> sector page and our general guide to <a href=\"\/en\/sa\/media-center\/restaurants-fire-safety-requirements\/\">restaurant and cafe fire safety<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6fae07 elementor-widget elementor-widget-text-editor\" data-id=\"e6fae07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key Points<\/h2><ul><li>Clause 4.6 requires compliance with all Saudi Fire Code requirements and bans storing highly flammable materials in the charcoal burner area.<\/li><li>The tobacco and burner preparation room must be fully separated from food preparation, with a non-combustible floor and a chimney fitted with an extract fan (clause 4.5).<\/li><li>Charcoal is stored in a dedicated space separated from the rest of the premises (clause 4.2).<\/li><li>Security cameras are required under the Security Surveillance Cameras Law and its implementing regulations (clause 5.4).<\/li><li>Extinguishers and alarm detectors are set by the approved design for each area, starting with the burner room and the charcoal store.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6720961 elementor-widget elementor-widget-text-editor\" data-id=\"6720961\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What do the tobacco products requirements say about safety?<\/h2>\n<p>The reference document is the &#8220;Requirements for Providing Tobacco Products&#8221;, issued under Ministerial Decision 4600156615\/1 dated 12\/4\/1446 AH and published on the Ministry of Municipalities and Housing website. It covers specialised shisha outlets and the restaurants and cafes that serve shisha, and it combines site, building and operating rules. These are the clauses that matter most for fire safety:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Clause<\/th><th>What it requires<\/th><th>Fire safety effect<\/th><\/tr><\/thead><tbody><tr><td>4.6 Security and safety<\/td><td>Comply with all Saudi Fire Code requirements; no highly flammable materials stored in the charcoal burner area<\/td><td>Extinguishers, alarms and exits follow SBC 801; the burner room stays clear of combustibles<\/td><\/tr><tr><td>4.5 Charcoal and tobacco preparation<\/td><td>Preparation and burner rooms fully separated from food cooking areas; non-combustible floor; chimney with extract fan discharging at the rear or inner side of the building<\/td><td>Keeps the ignition source in one room that is easy to protect<\/td><\/tr><tr><td>4.2 Storage<\/td><td>A dedicated store for tobacco tools, products and charcoal, separated from other sections<\/td><td>The charcoal store becomes its own hazard zone with a nearby extinguisher<\/td><\/tr><tr><td>4.1 Ventilation<\/td><td>Natural or mechanical ventilation; separate HVAC for the smoking lounge; air curtains on doors between sections<\/td><td>Limits smoke spread between areas and affects detector choice<\/td><\/tr><tr><td>4.3 Tobacco serving lounge<\/td><td>Self-closing external and internal doors for restaurants and cafes serving tobacco products<\/td><td>Slows smoke spread in a fire, as long as doors are not wedged open<\/td><\/tr><tr><td>5.4 Cameras<\/td><td>Security cameras under the Security Surveillance Cameras Law and its regulations<\/td><td>Records operations around the burner room and store<\/td><\/tr><tr><td>5.7 Preparation and service<\/td><td>Cooking charcoal may not be used for shisha<\/td><td>Keeps kitchen and shisha charcoal stocks apart<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The document does not state how many extinguishers to install or which detectors to use. Those details come from the fire code and the approved design for the floor area and occupancy, and Civil Defense reviews them when the Salamah safety licence is issued. A compliant fit-out therefore starts from the layout drawing, not from buying two extinguishers and hanging them by the door.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e632cec elementor-widget elementor-widget-text-editor\" data-id=\"e632cec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where do fires start in a shisha cafe?<\/h2>\n<p>Guests see comfortable lounges, sofas and cushions. The risk path starts behind the scenes:<\/p>\n<ul><li><strong>The burner room:<\/strong> charcoal burning continuously for hours, often lit on electric or gas heaters. Cardboard, bags or tissues near the burner are ready fuel, which is exactly what clause 4.6 bans.<\/li><li><strong>The charcoal store:<\/strong> bags of charcoal and used charcoal that is not fully out. Putting hot charcoal back into a bag or a wooden box is a common mistake.<\/li><li><strong>Ash:<\/strong> ash stays hot longer than staff expect. Emptying it into a general bin with tissues and cardboard is a familiar cause of late-night fires.<\/li><li><strong>The lounge:<\/strong> a coal falling from the bowl onto a cushion, rug or sofa. Modern foam and synthetic upholstery ignites quickly.<\/li><li><strong>Outdoor seating:<\/strong> canopies, screens and winter heaters. The requirements ban any electrical elements in the outdoor barrier (clause 4.3).<\/li><li><strong>Electrics:<\/strong> temporary wiring for lights, screens and heaters run under the seating.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd2ae5e elementor-widget elementor-widget-text-editor\" data-id=\"dd2ae5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Shisha cafe safety requirements: the right extinguisher for each area<\/h2>\n<p>Extinguishers are chosen for the fire expected in that spot, not for what happens to be in stock. A practical layout for the designer to confirm:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Area<\/th><th>Expected fire<\/th><th>Usual extinguisher<\/th><\/tr><\/thead><tbody><tr><td>Burner room<\/td><td>Burning charcoal and solids; electric or gas heater<\/td><td>Multi-purpose dry powder (ABC) at the room door, as the design sets<\/td><\/tr><tr><td>Charcoal store<\/td><td>Solids<\/td><td>Dry powder (ABC), or water\/foam for solid-material fires<\/td><\/tr><tr><td>Lounge<\/td><td>Upholstery and fabrics<\/td><td>Dry powder (ABC) spread so staff can reach one quickly from any seat<\/td><\/tr><tr><td>Electrical board and equipment room<\/td><td>Electrical fire<\/td><td>CO2, which leaves no residue on equipment<\/td><\/tr><tr><td>Cafe kitchen, if any<\/td><td>Cooking oils and fats<\/td><td>Wet chemical (Class K) extinguisher, plus a hood suppression system where needed<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Within its <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguisher range<\/a>, AZEIDK supplies Falcon Gold dry powder units of 1, 2, 3 and 6 kg, CO2 units of 2, 6 and 10 kg, 6 and 12 litre foam units and wheeled units for larger areas. If the cafe has a kitchen, see our guide to the <a href=\"\/en\/sa\/media-center\/nfpa-10-portable-fire-extinguishers-guide\/\">NFPA 10 portable extinguisher rules<\/a> and keep in mind that powder alone is not the answer for oil fires.<\/p>\n<p>Two points owners often miss: hang each extinguisher where it is visible, not hidden by decor or curtains, and make sure every staff member on each shift knows where it is and how to use it.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-705ee54 elementor-widget elementor-widget-text-editor\" data-id=\"705ee54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire alarm in a smoke-filled lounge: which detector?<\/h2>\n<p>This is the key technical question. A standard smoke detector responds to smoke particles, and a shisha lounge is full of smoke for its whole working day. Putting optical smoke detectors in the lounge without a design review means constant false alarms, followed by the worst fix of all: disconnecting or covering the detectors.<\/p>\n<ul><li><strong>Heat detectors<\/strong> in the burner room and kitchen, where heat and smoke are part of normal operation. A combined fixed-temperature and rate-of-rise heat detector picks up the sudden rise that normal operation does not produce.<\/li><li><strong>Heat detectors or detectors suited to a smoky environment<\/strong> in the smoking lounge, as the designer decides and the code accepts. The separate ventilation required by clause 4.1 also reduces smoke build-up.<\/li><li><strong>Smoke detectors<\/strong> in non-smoking areas: the non-smoking section, the store, the electrical room and offices.<\/li><li><strong>Manual call points<\/strong> at exits, and sounders loud enough to be heard over music and screens.<\/li><\/ul>\n<p>A small cafe is usually well served by a <a href=\"\/en\/sa\/media-center\/conventional-fire-alarm-panels-context-plus-fp\/\">conventional fire alarm panel<\/a> with enough zones for the lounge, burner room and store, such as Context Plus or FG panels with conventional heat detectors like the FGH-504. A large multi-floor cafe or one inside a complex may need an addressable panel that names each device. The final choice belongs to the approved designer under Chapter 9 of SBC 801.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a769a47 elementor-widget elementor-widget-text-editor\" data-id=\"a769a47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Ventilation and the chimney: why they matter for fire safety<\/h2>\n<ul><li>The chimney and extract fan over the burner (clause 4.5) remove heat and gases from the burner room. Soot builds up inside over time and needs regular cleaning because it can burn.<\/li><li>A non-combustible floor in the burner room stops a dropped coal turning into a fire.<\/li><li>Separate HVAC for the smoking lounge (clause 4.1) limits smoke spread to the non-smoking section, in normal use and in a fire.<\/li><li>The requirements also call for at least one air purifier per 25 m\u00b2 in smoking areas and an air curtain on doors between the two sections.<\/li><\/ul>\n<p>If the HVAC units must stop on alarm, that interface is designed between the alarm panel and the HVAC controls and tested at handover.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-577c3de elementor-widget elementor-widget-text-editor\" data-id=\"577c3de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Cameras: what is required and what helps safety<\/h2>\n<p>Clause 5.4 requires security cameras under the Security Surveillance Cameras Law and its implementing regulations. The general obligations are covered in our article on <a href=\"\/en\/sa\/media-center\/cctv-security-cameras-law-obligations-saudi\/\">CCTV law obligations in Saudi Arabia<\/a> and in <a href=\"\/en\/sa\/media-center\/restaurant-cafe-cctv-cameras-saudi\/\">CCTV cameras for restaurants and cafes<\/a>. A camera covering the burner room door and the charcoal store entrance helps staff keep those areas clear and shows how any incident began. AZEIDK supplies Hikvision and Dahua cameras and recorders through its <a href=\"\/en\/sa\/solutions\/security-surveillance-systems\/\">security and surveillance systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72983b5 elementor-widget elementor-widget-text-editor\" data-id=\"72983b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Pre-opening and pre-inspection checklist<\/h2>\n<ol><li>Burner room separated from the kitchen, non-combustible floor, chimney and extract fan working.<\/li><li>No cardboard, bags or flammable cleaning products in the burner area.<\/li><li>Charcoal kept in a dedicated store; used charcoal fully extinguished before disposal.<\/li><li>A lidded metal container for ash, away from general waste.<\/li><li>Extinguishers in visible positions, gauges in the green, inspection tags up to date.<\/li><li>Alarm panel fault-free; no detectors covered or disconnected.<\/li><li>Self-closing doors actually close; exit routes clear of extra chairs and tables.<\/li><li>Cameras recording, with retention as the law requires.<\/li><li>No temporary wiring in outdoor seating or barriers.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf46876 elementor-widget elementor-widget-text-editor\" data-id=\"bf46876\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Maintenance after opening<\/h2>\n<p>A shisha cafe runs long hours every day, so its equipment wears faster than in a normal shop. Extinguishers need a monthly visual check and periodic maintenance under NFPA 10, and detectors in a smoky space get dirty faster and need regular cleaning and testing. AZEIDK provides <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance contracts<\/a> for alarm, firefighting systems and extinguishers with its own team, and a visit log ready for inspections.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-286231c elementor-widget elementor-widget-text-editor\" data-id=\"286231c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What are the safety requirements for shisha cafes in Saudi Arabia?<\/h3><\/summary><p>The tobacco products requirements call for compliance with the Saudi Fire Code, a burner room separated from the kitchen, a dedicated charcoal store, no flammable materials near the burner and security cameras.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How many extinguishers does a shisha cafe need?<\/h3><\/summary><p>The approved design sets the number from floor area and travel distance. In practice that means one in the burner room, one in the store, several across the lounge and a CO2 unit at the electrical board.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can smoke detectors be used in a shisha lounge?<\/h3><\/summary><p>Standard smoke detectors cause false alarms in a smoking lounge. Designers usually choose heat detectors or detectors suited to that environment, and use smoke detectors in non-smoking areas.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Where should charcoal be stored?<\/h3><\/summary><p>In a dedicated space separated from other sections as clause 4.2 requires, away from the burner, and never with hot charcoal returned to it.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are CCTV cameras mandatory in a shisha cafe?<\/h3><\/summary><p>Yes. Clause 5.4 requires security cameras under the Security Surveillance Cameras Law and its implementing regulations.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which extinguisher suits the burner room?<\/h3><\/summary><p>A multi-purpose ABC dry powder extinguisher is the usual choice because it handles solids and electrical fires; the designer confirms the type and size.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6748355 elementor-widget elementor-widget-text-editor\" data-id=\"6748355\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Shisha cafe safety is more than a list of extinguishers. Separate the burner room and charcoal store as the requirements demand, place extinguishers by the fire type in each area, choose detectors that work in a smoky lounge, and keep a daily routine for ash and the store.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823e57e elementor-widget elementor-widget-text-editor\" data-id=\"823e57e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-related\">Related reading: <a href=\"\/en\/sa\/media-center\/kids-indoor-play-centers-fire-safety\/\">Indoor Kids Play Centers Fire Safety in Saudi Arabia<\/a>, <a href=\"\/en\/sa\/media-center\/furniture-showrooms-fire-safety-saudi\/\">Furniture Showroom Fire Safety in Saudi Arabia<\/a> and <a href=\"\/en\/sa\/media-center\/momah-vehicle-repair-workshops-requirements-fire-cctv-news-en\/\">Vehicle Repair Workshop Requirements in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7baa039 elementor-widget elementor-widget-text-editor\" data-id=\"7baa039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Fitting out a cafe or checking it before inspection?<\/strong> Send us the layout or site photos and we will propose the extinguisher layout, fire alarm and cameras with datasheets. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92b50e6 elementor-widget elementor-widget-text-editor\" data-id=\"92b50e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/momah.gov.sa\/sites\/default\/files\/2024-10\/ashtratat%20tqdym%20mntjat%20altbgh.pdf\" rel=\"noopener\" target=\"_blank\">Requirements for Providing Tobacco Products, 1446 AH<\/a> (Ministry of Municipalities and Housing); <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-10-standard-development\/10\" rel=\"noopener\" target=\"_blank\">NFPA 10<\/a> (NFPA)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Shisha cafe safety requirements in Saudi Arabia: burner room and charcoal storage rules, ventilation, extinguishers, fire alarm and CCTV cameras.<\/p>\n","protected":false},"author":0,"featured_media":27980,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-28002","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28002","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28002"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28002\/revisions"}],"predecessor-version":[{"id":28273,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28002\/revisions\/28273"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/27980"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28002"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28002"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28002"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28002"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}