{"id":28000,"date":"2026-11-20T16:35:44","date_gmt":"2026-11-20T13:35:44","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T11:31:10","modified_gmt":"2026-11-21T08:31:10","slug":"kids-indoor-play-centers-fire-safety","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/kids-indoor-play-centers-fire-safety\/","title":{"rendered":"Indoor Kids Play Centers Fire Safety in Saudi Arabia: Foam, Alarms, Extinguishers and Exits"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28000\" class=\"elementor elementor-28000 elementor-27999 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce0b8c1 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"ce0b8c1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d918f00 elementor-widget elementor-widget-text-editor\" data-id=\"d918f00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Indoor kids play centers<\/strong> in Saudi Arabia fall under the Recreational Facilities Requirements issued by the Ministry of Municipalities and Housing. For fire protection the requirements refer to the Saudi Fire Code (SBC 801), and they also call for security cameras and an operations room that overlooks every play area. The particular risk is twofold: enclosed play frames built from foam and plastic, and young children who cannot evacuate quickly on their own.<\/p>\n<p>For the steps to obtain the <a href=\"\/en\/sa\/media-center\/salamah-certificate-civil-defense-guide\/\">Salamah certificate<\/a> from Civil Defense on the Salamah platform, see our guide; our page on <a href=\"\/en\/sa\/media-center\/saudi-civil-defense-requirements-buildings-facilities\/\">Saudi Civil Defense requirements<\/a> covers the general requirements for buildings and facilities.<\/p>\n<p>This article covers what the requirements say, what the European standard EN 1176-10 adds for enclosed play equipment, and how to plan the <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm system<\/a>, <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguishers<\/a> and exits for a play center in a mall or a standalone building. It belongs to our <a href=\"\/en\/sa\/industries\/entertainment-event-halls\/\">entertainment venues and event halls<\/a> sector page and complements our article on <a href=\"\/en\/sa\/media-center\/cinemas-entertainment-venues-fire-safety\/\">cinema and entertainment venue fire safety<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0440e56 elementor-widget elementor-widget-text-editor\" data-id=\"0440e56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key Points<\/h2><ul><li>The Recreational Facilities Requirements call for compliance with SBC 801, fire-resistant ceilings and stairs and walkways kept clear for evacuation.<\/li><li>They require an operations and monitoring room overlooking all play areas, and security cameras under the Security Surveillance Cameras Law.<\/li><li>EN 1176-10:2023 for enclosed play equipment requires flame-retardant materials, an adult access route of at least 1,300 x 700 mm and no point more than 18 m from the nearest exit.<\/li><li>Alarms in a play center need sound and light together: noise levels are high and children are spread through enclosed frames.<\/li><li>The emergency plan must name who checks inside the play frame before the area is declared clear.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee298f6 elementor-widget elementor-widget-text-editor\" data-id=\"ee298f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why a kids play center is different<\/h2>\n<ul><li><strong>Foam and plastic fire load:<\/strong> mats, cushions, foam-wrapped tubes, PVC covers and ball pits. Untreated, these materials burn fast and produce dense smoke.<\/li><li><strong>Multi-level enclosed frames:<\/strong> tunnels and slides that adults struggle to enter, where a child cannot see the exit.<\/li><li><strong>Occupants who cannot self-evacuate:<\/strong> small children need leading, and parents are spread across the cafe and waiting area.<\/li><li><strong>Party rooms:<\/strong> balloons, paper decorations, fabrics and birthday candles.<\/li><li><strong>Electrical equipment:<\/strong> arcade games, screens, blowers for inflatables and sound systems.<\/li><li><strong>A small cafe or kitchen<\/strong> serving parents.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-71a6069 elementor-widget elementor-widget-text-editor\" data-id=\"71a6069\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What do the Recreational Facilities Requirements say?<\/h2>\n<p>On 14 May 2025 the Ministry of Municipalities and Housing announced updated requirements for recreational facilities. They apply to recreational facility buildings, including entertainment centers and amusement parks with their play corners, maze and puzzle rooms and hobby corners, and exclude cinemas and theaters. The clauses closest to safety:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Clause<\/th><th>Requirement<\/th><th>What it means for the owner<\/th><\/tr><\/thead><tbody><tr><td>4.7<\/td><td>Comply with the Saudi Fire Code (SBC 801)<\/td><td>Alarm, extinguishers and exits are designed to the code and reviewed for the Salamah licence<\/td><\/tr><tr><td>4.6.1<\/td><td>Ceilings of fire-resistant materials<\/td><td>Watch false ceilings and hanging decor over play areas<\/td><\/tr><tr><td>4.4.6<\/td><td>Stairs and external walkways free of obstructions for fast evacuation<\/td><td>No strollers or advertising stands on exit routes<\/td><\/tr><tr><td>5.1.11<\/td><td>Entrance decorations must not block building openings, especially escape openings in a fire<\/td><td>Entrance decor stays clear of escape windows and openings<\/td><\/tr><tr><td>4.2.4<\/td><td>An operations and monitoring room whose field of view covers all play areas<\/td><td>A natural home for the alarm panel and camera monitoring<\/td><\/tr><tr><td>5.3<\/td><td>Security cameras under the Security Surveillance Cameras Law<\/td><td>Coverage of entrances and play areas as the law requires<\/td><\/tr><tr><td>4.1.1<\/td><td>Comply with the Saudi Building Code, including its electrical requirements<\/td><td>Fixed wiring, not temporary leads, for games and blowers<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The requirements do not specify detector types or extinguisher numbers; the approved design sets those under the code for the floor area and occupancy.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3721efb elementor-widget elementor-widget-text-editor\" data-id=\"3721efb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What EN 1176-10 adds for enclosed play equipment<\/h2>\n<p>Most indoor play frames are imported, and many suppliers build them to EN 1176-10:2023, the European standard for fully enclosed play equipment for children up to 14. It is a technical reference the owner or consultant can specify, not a replacement for the Saudi code, but it gives useful questions at purchase stage:<\/p>\n<ul><li><strong>Flame-retardant materials:<\/strong> clause 4.2.1 requires materials and components of enclosed play equipment to be flame retardant, tested to EN ISO 11925-2 or EN 1021-1 and EN 1021-2 where practical. Ask the supplier for the test reports before delivery.<\/li><li><strong>Adult access route:<\/strong> at least 1,300 mm high and 700 mm wide, so a supervisor can reach an injured or stuck child and bring them out.<\/li><li><strong>Distance to exit:<\/strong> no more than 18 m from any point in the equipment to the nearest exit.<\/li><li><strong>Emergency procedures and fire safety management:<\/strong> the standard has a dedicated clause, so evacuation is part of the equipment design itself.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-10267a9 elementor-widget elementor-widget-text-editor\" data-id=\"10267a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The right fire alarm system for indoor kids play centers<\/h2>\n<ul><li><strong>Detection over play areas:<\/strong> ceiling smoke detectors spaced for the ceiling height; in tall halls the designer may use <a href=\"\/en\/sa\/media-center\/warehouse-smoke-detectors-beam-vs-point\/\">beam smoke detectors<\/a>. If the roof of an enclosed frame keeps smoke from ceiling detectors, the designer reviews the need for extra detection.<\/li><li><strong>Heat detectors<\/strong> in the kitchen or cafe corner, where fumes are part of normal use.<\/li><li><strong>An addressable panel<\/strong> for medium and large centers, naming the device location instantly in a space full of corners. AZEIDK supplies Context Plus addressable panels in single and multi-loop options.<\/li><li><strong>Audible and visual alarm:<\/strong> sounders with strobes, because sound alone can be lost in the noise and a child in a tunnel may not hear but will see the light.<\/li><li><strong>A calm recorded voice message<\/strong> in larger centers, directing parents to exits and reducing panic.<\/li><li><strong>The panel in the operations room<\/strong> the requirements call for, so the operator sees the alarm and the play areas at once.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ba2bf7 elementor-widget elementor-widget-text-editor\" data-id=\"5ba2bf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Extinguishers in a play center<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Area<\/th><th>Expected fire<\/th><th>Usual extinguisher<\/th><\/tr><\/thead><tbody><tr><td>Main play area<\/td><td>Foam, fabric and plastic<\/td><td>ABC dry powder or water\/foam for solids, mounted out of children&#8217;s reach and protected from tampering<\/td><\/tr><tr><td>Party rooms<\/td><td>Decorations, fabric and paper<\/td><td>ABC dry powder<\/td><\/tr><tr><td>Arcade zone and electrical room<\/td><td>Electrical fire<\/td><td>CO2<\/td><\/tr><tr><td>Kitchen or cafe<\/td><td>Appliances, oils if frying<\/td><td>CO2 for appliances; Class K where there is frying<\/td><\/tr><\/tbody><\/table><\/div>\n<p>AZEIDK supplies Falcon Gold dry powder, foam and CO2 extinguishers in several sizes. Extinguishers can sit in <a href=\"\/en\/sa\/products\/?product_category=fire-cabinet\">fire cabinets<\/a> or recessed extinguisher boxes so they do not project into children&#8217;s routes, as long as they stay visible and signed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87ac191 elementor-widget elementor-widget-text-editor\" data-id=\"87ac191\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Exits and emergency lighting<\/h2>\n<ul><li>Make illuminated exit signs visible from inside the play area and from the cafe; see our article on <a href=\"\/en\/sa\/media-center\/emergency-lighting-exit-signs-saudi\/\">emergency lighting and exit signs<\/a>.<\/li><li>Emergency lighting should cover the routes from the play frame to the exit, not only the general corridors.<\/li><li>An entry gate that stops children leaving unaccompanied must release automatically on alarm; that interface between the alarm panel and access control is designed and tested at handover.<\/li><li>Strollers, shoes and bags stay off exit routes, in line with clause 4.4.6.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba0eec5 elementor-widget elementor-widget-text-editor\" data-id=\"ba0eec5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Cameras and the operations room<\/h2>\n<p>An operations room overlooking the play areas, with cameras covering what the window cannot see, gives the operator a full picture during an alarm: where the children are and whether an area is clear. AZEIDK supplies Hikvision and Dahua cameras and recorders through its <a href=\"\/en\/sa\/solutions\/security-surveillance-systems\/\">security and surveillance systems<\/a>; the general legal obligations are covered in our article on the <a href=\"\/en\/sa\/media-center\/cctv-security-cameras-law-obligations-saudi\/\">Security Surveillance Cameras Law<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1aa4803 elementor-widget elementor-widget-text-editor\" data-id=\"1aa4803\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The emergency plan: who checks inside the frame?<\/h2>\n<p>The single most important line in a play center emergency plan is the named staff member who enters the enclosed frame and confirms it is empty before evacuation is declared complete. Roles for each shift should be written down: who triggers the alarm, who opens exits, who sweeps the frame, and who gathers children at the assembly point until parents collect them. The adult access route required by EN 1176-10 is the path that person will take.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccfe844 elementor-widget elementor-widget-text-editor\" data-id=\"ccfe844\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Periodic maintenance<\/h2>\n<p>Dust and fibres from fabrics and foam settle on detectors faster than usual, and extinguishers in children&#8217;s areas get tampered with. Detectors need regular cleaning and testing and extinguishers a monthly check. AZEIDK provides <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance contracts<\/a> for alarms and extinguishers with its own team, and <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> ahead of the Salamah licence.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ee579d elementor-widget elementor-widget-text-editor\" data-id=\"4ee579d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What are the safety requirements for indoor kids play centers?<\/h3><\/summary><p>The Recreational Facilities Requirements call for SBC 801 compliance, fire-resistant ceilings, clear evacuation routes, an operations room overlooking play areas and security cameras.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Must play foam be fire resistant?<\/h3><\/summary><p>EN 1176-10 requires enclosed play equipment materials to be flame retardant. Ask the supplier for test reports; the consultant checks what the Saudi code requires.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the maximum distance to an exit inside an enclosed play frame?<\/h3><\/summary><p>EN 1176-10:2023 sets no more than 18 m from any point in the equipment to the nearest exit.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a bell enough in a play center?<\/h3><\/summary><p>Sounders with strobes are better because of the noise and children inside tunnels; larger centers may add a voice message.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Where should the fire alarm panel go?<\/h3><\/summary><p>In the operations and monitoring room the requirements call for, or another position set by the design that is staffed during opening hours.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does the children&#8217;s entry gate need an alarm interface?<\/h3><\/summary><p>Yes. Any locked gate or door on an exit route must release on alarm, and the interface is tested at handover.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68424c4 elementor-widget elementor-widget-text-editor\" data-id=\"68424c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Fire safety in an indoor kids play center starts before opening: flame-retardant play materials with test reports, an alarm that can be seen and heard over the noise, extinguishers out of children&#8217;s reach, clear exits and a named staff member who sweeps the play frame on alarm.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a93473d elementor-widget elementor-widget-text-editor\" data-id=\"a93473d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-related\">Related reading: <a href=\"\/en\/sa\/media-center\/furniture-showrooms-fire-safety-saudi\/\">Furniture Showroom Fire Safety in Saudi Arabia<\/a>, <a href=\"\/en\/sa\/media-center\/momah-vehicle-repair-workshops-requirements-fire-cctv-news-en\/\">Vehicle Repair Workshop Requirements in Saudi Arabia<\/a> and <a href=\"\/en\/sa\/media-center\/tourism-hospitality-facility-regulation-civil-defense-news-en\/\">Tourist Hospitality Facility Regulation in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dcc435b elementor-widget elementor-widget-text-editor\" data-id=\"dcc435b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Fitting out a kids play center in a mall or standalone building?<\/strong> Send us the layout and equipment plan and we will propose the fire alarm, extinguishers and cameras with datasheets. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3d2213 elementor-widget elementor-widget-text-editor\" data-id=\"c3d2213\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/momah.gov.sa\/sites\/default\/files\/2024-11\/ashtratat%20almrafq%20altrfyhyt.pdf\" rel=\"noopener\" target=\"_blank\">Recreational Facilities Requirements<\/a> (Ministry of Municipalities and Housing); <a href=\"https:\/\/momah.gov.sa\/en\/node\/14899\" rel=\"noopener\" target=\"_blank\">Announcement of updated requirements, 14 May 2025<\/a>; <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/6038c521-6c36-40a2-ad59-b106d533280f\/en-1176-10-2023\" rel=\"noopener\" target=\"_blank\">EN 1176-10:2023<\/a> (CEN)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Indoor kids play centers in Saudi Arabia: recreational facility rules, EN 1176-10 for enclosed play frames, alarms, extinguishers and exits.<\/p>\n","protected":false},"author":0,"featured_media":27982,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-28000","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28000","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28000"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28000\/revisions"}],"predecessor-version":[{"id":28275,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28000\/revisions\/28275"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/27982"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28000"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28000"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28000"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28000"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}