{"id":27994,"date":"2026-11-20T16:35:37","date_gmt":"2026-11-20T13:35:37","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-20T16:35:38","modified_gmt":"2026-11-20T13:35:38","slug":"coffee-roastery-fire-protection-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/coffee-roastery-fire-protection-saudi\/","title":{"rendered":"Coffee Roastery Fire Safety in Saudi Arabia: Chaff, Stacks, Extinguishers and Fire Alarm"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"27994\" class=\"elementor elementor-27994 elementor-27993 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c70a73e e-con-full az-el-article e-flex e-con e-parent\" data-id=\"c70a73e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fef770c elementor-widget elementor-widget-text-editor\" data-id=\"fef770c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Coffee roastery fire safety<\/strong> starts with the source of the risk: chaff, the thin skin that comes off the beans during roasting, is highly combustible and builds up in the chaff collector (cyclone) and exhaust ducts. Most roaster fires start there, not in the shop. Protection rests on three things: regular cleaning, the right extinguishers for each area, and a fire alarm that can tell normal roasting smoke from a real fire.<\/p>\n<p>This article is for specialty roasteries and coffee shops that roast on site. It covers where fires start, what the roaster should do if the machine catches fire, which <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguishers<\/a> suit each area, and how to design a <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm system<\/a> for a space that produces smoke every day. It links to our <a href=\"\/en\/sa\/industries\/restaurants-commercial-kitchens\/\">restaurants and commercial kitchens<\/a> and <a href=\"\/en\/sa\/industries\/industrial-facilities\/\">industrial facilities<\/a> sector pages for larger roasting plants.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e480343 elementor-widget elementor-widget-text-editor\" data-id=\"e480343\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key Points<\/h2><ul><li>Chaff is highly combustible and its build-up is a fire risk; industry guidance is to clear the chaff collector and cyclone after every roasting session.<\/li><li>Roasting experts identify the cyclone as the place where most roaster fires occur.<\/li><li>A cyclone temperature rising above its usual range during a roast is an early sign that a fire may be imminent.<\/li><li>Opening the discharge door during a fire dumps burning beans and flames into the cooling tray, which specialists warn against.<\/li><li>A roaster inside a building falls under the Saudi Fire Code (SBC 801) and the Salamah safety licence; the approved design sets extinguishers and detectors.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c3d288 elementor-widget elementor-widget-text-editor\" data-id=\"0c3d288\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why do coffee roasters catch fire?<\/h2>\n<p>A commercial roaster is a drum turning over a gas burner or electric heat source, with a fan drawing hot air through the beans, into the chaff collector and up the stack. Three factors make that path prone to fire:<\/p>\n<ul><li><strong>Chaff:<\/strong> Perfect Daily Grind&#8217;s roaster maintenance guide (June 2026) puts it plainly: &#8220;Chaff is highly combustible, and accumulation is a fire risk.&#8221;<\/li><li><strong>Oils and residue:<\/strong> darker roasts in particular release oils and particles that coat air ducts, cooling tray screens and filters. Roaster maker Loring states that blocked airflow leads to uneven roasting, system malfunction &#8220;or even fire.&#8221;<\/li><li><strong>Continuous heat:<\/strong> roasters run back-to-back batches, and any fault in the burner, fan or temperature probe pushes temperatures beyond normal.<\/li><\/ul>\n<p>Roasting consultant Scott Rao writes that the cyclone is where most roaster fires occur, and that its temperature is usually stable during a roast; if it starts to rise out of its usual range, a fire may be imminent.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be2bdda elementor-widget elementor-widget-text-editor\" data-id=\"be2bdda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What to do if the roaster catches fire<\/h2>\n<p>Rule one: follow the emergency procedure in the manufacturer&#8217;s operating manual, and train everyone who roasts on it before they need it. Loring asks owners to train all staff on controls and emergency procedures and offers emergency guidance through its support team. From published specialist experience:<\/p>\n<ul><li><strong>Do not open the discharge door.<\/strong> Rao describes an incident in which a member of his staff opened it, spilling burning beans and flames into the cooling bin, and says: please don&#8217;t do that.<\/li><li><strong>An extinguisher into the drum is not ideal.<\/strong> Spraying through the trier port is possible but awkward and coats the drum with agent.<\/li><li><strong>A fixed water line.<\/strong> Rao recommends a water line plumbed into the drum face plate and another into the cyclone, with a shut-off valve within reach and a spray nozzle purged of chaff at the start and end of each roast day. Make such changes only with the manufacturer&#8217;s or agent&#8217;s approval.<\/li><li><strong>Cyclone temperature alarm.<\/strong> Tracking cyclone temperature in the roasting software with a high-limit alarm on its thermocouple buys the roaster valuable minutes.<\/li><\/ul>\n<p>If the fire spreads beyond the machine, the priority becomes evacuating, raising the alarm and calling Civil Defense, then using an extinguisher only if it is safe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a149266 elementor-widget elementor-widget-text-editor\" data-id=\"a149266\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Coffee roastery fire safety: the right extinguisher for each area<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Area<\/th><th>Expected fire<\/th><th>Usual extinguisher<\/th><\/tr><\/thead><tbody><tr><td>Roasting area<\/td><td>Chaff, beans and solids; gas burner<\/td><td>Multi-purpose ABC dry powder at a safe distance from the roaster, on the exit route<\/td><\/tr><tr><td>Green coffee store<\/td><td>Jute sacks, cardboard and wooden pallets<\/td><td>ABC dry powder, or water\/foam for solids<\/td><\/tr><tr><td>Packing area<\/td><td>Packaging, cardboard and bag sealers<\/td><td>ABC dry powder<\/td><\/tr><tr><td>Electrical board and roaster control panel<\/td><td>Electrical fire<\/td><td>CO2<\/td><\/tr><tr><td>Coffee bar or shop kitchen<\/td><td>Appliances, and oils if frying<\/td><td>CO2 for appliances; Class K wet chemical where there is frying<\/td><\/tr><\/tbody><\/table><\/div>\n<p>AZEIDK supplies Falcon Gold dry powder extinguishers of 1, 2, 3 and 6 kg, CO2 units of 2, 6 and 10 kg, 6 and 12 litre foam units and wheeled units for roasteries with large stores. The approved design sets numbers and travel distances under the code; see our guide to <a href=\"\/en\/sa\/media-center\/nfpa-10-portable-fire-extinguishers-guide\/\">NFPA 10 portable extinguishers<\/a> for the general rules.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38e4fb4 elementor-widget elementor-widget-text-editor\" data-id=\"38e4fb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire alarm in a roastery: heat or smoke detectors?<\/h2>\n<p>Roasting produces smoke and odour every day, especially at the end of a batch and while beans cool. A smoke detector above the roaster will give false alarms, and repeated false alarms teach staff to ignore the system. The usual layout for the designer to confirm:<\/p>\n<ul><li><strong>Heat detectors<\/strong> in the roasting room, preferably combined fixed-temperature and rate-of-rise, such as the FGH-504 conventional heat detector or Context Plus addressable heat detectors on larger projects.<\/li><li><strong>Smoke detectors<\/strong> in the green coffee store, packing area and offices, where normal operation produces no smoke and a fire usually starts with smoke before flame.<\/li><li><strong>A beam smoke detector<\/strong> in a high-ceiling store where the designer sees fit, such as the SFP-CBM-100M conventional beam detector.<\/li><li><strong>Manual call points<\/strong> at exits, with sounders audible over the roaster fan and grinder.<\/li><\/ul>\n<p>The cyclone temperature alarm in the roaster software is not the building fire alarm. The first is an early warning for the roaster; the second protects the building and its occupants under Chapter 9 of SBC 801. A well-run roastery needs both.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d76c0e5 elementor-widget elementor-widget-text-editor\" data-id=\"d76c0e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The stack and exhaust ducts<\/h2>\n<ul><li>Run the stack with the materials and clearances to combustibles set out in the manufacturer&#8217;s installation manual.<\/li><li>Provide cleanout openings; a duct that cannot be cleaned will fill with residue over time.<\/li><li>Coordinate the stack outlet with the facade, neighbours and municipality requirements.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfbc7fc elementor-widget elementor-widget-text-editor\" data-id=\"dfbc7fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>A cleaning schedule that cuts fire risk<\/h2>\n<p>Daily maintenance is the strongest prevention in a roastery. These examples come from industry sources; your roaster&#8217;s manual always takes priority:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Task<\/th><th>Stated frequency<\/th><th>Source<\/th><\/tr><\/thead><tbody><tr><td>Clear chaff collector and cyclone<\/td><td>After every roasting session<\/td><td>Perfect Daily Grind<\/td><\/tr><tr><td>Check burners, airflow and chaff collector<\/td><td>Daily<\/td><td>Perfect Daily Grind<\/td><\/tr><tr><td>Empty chaff barrel<\/td><td>About every 10 roasts or at the full line<\/td><td>Loring<\/td><\/tr><tr><td>Inspect chaff barrel lid and cyclone<\/td><td>Weekly<\/td><td>Loring<\/td><\/tr><tr><td>Verify ignition and burner function<\/td><td>Daily<\/td><td>Loring<\/td><\/tr><tr><td>Written or digital maintenance log<\/td><td>Ongoing<\/td><td>Both<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Loring also warns to let the roaster cool completely before cleaning, because hot surfaces can vaporise cleaning products.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffe010c elementor-widget elementor-widget-text-editor\" data-id=\"ffe010c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Gas and electrics<\/h2>\n<p>Many roasters are gas-fired, so the gas line, isolation valve and leak checks are part of fire safety. If the building runs on a central gas tank, see our article on <a href=\"\/en\/sa\/media-center\/central-gas-tank-requirements-saudi\/\">central gas tank requirements and gas detection<\/a>. The roaster, grinder and packing machine are heavy loads that need dedicated circuits and an electrical board that is never used as a cardboard store.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b58a0f5 elementor-widget elementor-widget-text-editor\" data-id=\"b58a0f5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Licensing and periodic maintenance<\/h2>\n<p>Whether it is a corner of a coffee shop or a standalone plant, a roastery needs a Salamah safety certificate as part of its activity licence; see <a href=\"\/en\/sa\/media-center\/salamah-certificate-shops-balady\/\">the Salamah certificate for shops and Balady licensing<\/a>. AZEIDK provides <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> and issues the safety equipment installation certificate for the systems it installs, along with <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">periodic maintenance contracts<\/a> for alarms and extinguishers delivered by its own team.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43303b2 elementor-widget elementor-widget-text-editor\" data-id=\"43303b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What causes coffee roaster fires?<\/h3><\/summary><p>Mostly chaff build-up in the chaff collector, cyclone and exhaust ducts, plus oils and residue blocking airflow and burner or fan faults.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Should I open the roaster door if the beans catch fire?<\/h3><\/summary><p>No. Opening the discharge door spills burning beans and flames into the cooling tray. Follow the manufacturer&#8217;s emergency procedure.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How often should the chaff collector be emptied?<\/h3><\/summary><p>Perfect Daily Grind advises after every roasting session, and Loring cites the chaff barrel about every 10 roasts. Follow your roaster&#8217;s manual.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can I install a smoke detector above the roaster?<\/h3><\/summary><p>It will cause false alarms. The usual choice is heat detectors in the roasting room and smoke detectors in the store and packing area, as the designer decides.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which extinguisher suits a coffee roastery?<\/h3><\/summary><p>ABC dry powder for the roasting area and store and CO2 for electrical boards; the design sets numbers and positions.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does a roastery need a safety certificate?<\/h3><\/summary><p>Yes. Roasting is a licensed activity that needs a Civil Defense safety certificate within the municipal licence.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2d4d5b elementor-widget elementor-widget-text-editor\" data-id=\"b2d4d5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Coffee roastery fire safety depends on daily cleaning before any device. Clear chaff on schedule, watch cyclone temperature, train roasters on the emergency procedure without opening the discharge door, then place extinguishers and choose heat or smoke detection to suit each area.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-954bdd0 elementor-widget elementor-widget-text-editor\" data-id=\"954bdd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Opening a roastery or moving your roaster to a new site?<\/strong> Send us the layout with the roaster and store positions and we will propose extinguishers and a fire alarm system with datasheets. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c2f129 elementor-widget elementor-widget-text-editor\" data-id=\"7c2f129\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/perfectdailygrind.com\/2026\/06\/guide-to-preventive-maintenance-coffee-roasters\/\" rel=\"noopener\" target=\"_blank\">A guide to preventive maintenance for coffee roasters<\/a> (Perfect Daily Grind, June 2026); <a href=\"https:\/\/loring.com\/maintenance-cleaning-safety-tips-for-loring-commercial-coffee-roasters\/\" rel=\"noopener\" target=\"_blank\">Maintenance, Cleaning and Safety Tips<\/a> (Loring); <a href=\"https:\/\/scottrao.com\/blog\/fire\" rel=\"noopener\" target=\"_blank\">The Most Important Thing Few Roasters Bother to Do<\/a> (Scott Rao, April 2017)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Coffee roastery fire safety: why chaff ignites in the cyclone, what to do in a roaster fire, and the right extinguishers, detectors and cleaning.<\/p>\n","protected":false},"author":0,"featured_media":27975,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-27994","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27994","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=27994"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27994\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/27975"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=27994"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=27994"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=27994"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=27994"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}