{"id":27653,"date":"2026-11-20T15:38:52","date_gmt":"2026-11-20T12:38:52","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-22T15:22:16","modified_gmt":"2026-11-22T12:22:16","slug":"mall-fire-sprinkler-system-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/mall-fire-sprinkler-system-saudi\/","title":{"rendered":"Mall Fire Sprinkler Systems: Corridors, Shops, Hypermarkets, Car Parks and High Ceilings"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"27653\" class=\"elementor elementor-27653 elementor-27652 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6318845 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"6318845\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-103e57b elementor-widget elementor-widget-text-editor\" data-id=\"103e57b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Mall fire sprinkler systems<\/strong> cover very different spaces under one roof: corridors and a high atrium, small shops with false ceilings, a hypermarket with tall racks, restaurants and kitchens, and car parks. A mall cannot be designed with one sprinkler and one spacing. The network is split by the nature and hazard classification of each space, and tenant changes are managed so the system does not lose coverage over time.<\/p>\n<p>This article covers sprinkler selection for each mall area, what high storage changes, and how shop fit-outs are reviewed. AZEIDK supplies <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>, TYCO and Victaulic sprinklers and fire pumps for <a href=\"\/en\/sa\/industries\/commercial-buildings\/\">malls and commercial buildings<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efe0f24 elementor-widget elementor-widget-text-editor\" data-id=\"efe0f24\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>The 2021 IBC requires sprinklers throughout covered and open malls. In Saudi Arabia SBC 801 and Civil Defense are binding.<\/li><li>Stand-alone retail buildings need sprinklers in the IBC above certain area or height limits, or with high-piled or rack storage.<\/li><li>Hypermarket racks may need storage sprinklers with a higher K-factor than corridor sprinklers.<\/li><li>Each zone or floor has a supervised valve and flow switch, so the control room sees where water flows and one zone can be isolated without shutting the mall.<\/li><li>Shop fit-outs are the main cause of lost coverage; drawings are reviewed before work and modified sections tested before opening.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c04ff3 elementor-widget elementor-widget-text-editor\" data-id=\"7c04ff3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When are sprinklers required in malls and shops?<\/h2>\n<p>In Saudi Arabia the binding references are the Saudi Fire Protection Code SBC 801, the Saudi Building Code and Civil Defense requirements. For comparison, the 2021 International Building Code requires sprinklers throughout covered and open malls, with the system complete and operational before occupancy. Group M retail buildings outside malls need sprinklers under the IBC where any of the following applies:<\/p>\n<table><thead><tr><th>IBC 2021 condition<\/th><th>Value<\/th><\/tr><\/thead><tbody><tr><td>Group M fire area<\/td><td>Over 12,000 sq ft (about 1,115 m\u00b2)<\/td><\/tr><tr><td>Location of the Group M fire area<\/td><td>Four or more stories above grade plane<\/td><\/tr><tr><td>Total of all Group M fire areas<\/td><td>Over 24,000 sq ft (about 2,230 m\u00b2)<\/td><\/tr><tr><td>Storage<\/td><td>High-piled or rack storage of merchandise per the IFC<\/td><\/tr><\/tbody><\/table>\n<p>These are reference limits from a foreign code; the consultant sets what your project needs under the Saudi code.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3a870e elementor-widget elementor-widget-text-editor\" data-id=\"b3a870e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Sprinkler selection by mall area<\/h2>\n<table><thead><tr><th>Area<\/th><th>Common choice<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Corridors and shops<\/td><td>Standard K5.6 pendent or concealed sprinklers<\/td><td>Concealed suits exposed architectural ceilings<\/td><\/tr><tr><td>Hypermarket and stores<\/td><td>Storage sprinklers; the designer may choose ESFR by storage and ceiling height<\/td><td>NFPA 13 sets criteria by commodity and storage arrangement<\/td><\/tr><tr><td>Restaurants and food court<\/td><td>Building sprinklers plus hood suppression over cooking<\/td><td>The hood system is designed and maintained separately<\/td><\/tr><tr><td>Car parks<\/td><td>Per design and hazard classification<\/td><td>Allow for headroom and traffic routes<\/td><\/tr><tr><td>Electrical and server rooms<\/td><td>Per design, possibly gas suppression<\/td><td>Limits water impact on equipment<\/td><\/tr><\/tbody><\/table>\n<p>Sprinklers AZEIDK supplies include <a href=\"\/en\/sa\/products\/victaulic-firelock-v27-k5-6-fire-sprinklers-v2703-v2704-v2707-and-v2708\/\">Victaulic FireLock V27 K5.6<\/a>, <a href=\"\/en\/sa\/products\/tyco-series-ty-b-upright-pendent-and-recessed-pendent-fire-sprinklers\/\">TYCO Series TY-B<\/a>, <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-sr-st-k11-2-storage-sprinklers-v3403-and-v3407\/\">Victaulic FL-SR\/ST K11.2 storage sprinklers<\/a> and the <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-qr-st-esfr-k16-8-pendent-storage-sprinkler-v4702\/\">Victaulic ESFR K16.8 pendent sprinkler<\/a>. The model is chosen after hydraulic calculations and datasheet review. Where sprinklers are not the right primary choice, as in server rooms or kitchens, our <a href=\"\/en\/sa\/media-center\/fire-fighting-system-selection-guide\/\">fire fighting system selection guide<\/a> compares the alternatives.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2190b2 elementor-widget elementor-widget-text-editor\" data-id=\"b2190b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why a hypermarket inside a mall is different<\/h2>\n<p>Hypermarket racks can reach heights where corridor sprinklers are not enough, especially with plastic goods and flammable products. Commodity class, storage height, ceiling height and stacking method drive the sprinkler and density, and the design may call for storage or ESFR sprinklers. The tenant should be told the storage limits used in the design, because raising racks later or changing goods can take the space outside the basis of the design. See our article on <a href=\"\/en\/sa\/media-center\/warehouse-high-rack-storage-fire-protection-esfr\/\">high-rack storage protection with ESFR<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6809b15 elementor-widget elementor-widget-text-editor\" data-id=\"6809b15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Zoning and water supply<\/h2>\n<p>In a large mall the sprinkler system is split into zones, each with a supervised control valve and a flow switch that signals the fire alarm panel. The control room sees which zone operated, and one zone can be isolated for a shop change without shutting the rest of the mall. The system is fed by fire pumps, with an external fire department connection.<\/p>\n<p>AZEIDK supplies fire pumps from SFFECO, WATEX and Jack Pump. When a project specification calls for another brand, AZEIDK&#8217;s supply team works on sourcing it to the required specification and approvals.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86ea121 elementor-widget elementor-widget-text-editor\" data-id=\"86ea121\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Shop fit-outs: the biggest risk to coverage<\/h2>\n<p>Each new tenant changes ceilings, adds partitions, tall shelving or suspended display ceilings. Any of these can block spray or leave a new room without a sprinkler. Mall management needs to:<\/p>\n<ul><li>Review the revised sprinkler drawing for each shop before work.<\/li><li>Use sprinklers of the same type and response in the same area.<\/li><li>Test the modified section and check for leaks before closing the ceiling.<\/li><li>Update as-built drawings after every change.<\/li><\/ul>\n<p>Relocation steps during fit-out are in our <a href=\"\/en\/sa\/media-center\/sprinkler-relocation-shop-fit-out-mall\/\">sprinkler relocation in shop fit-outs<\/a> article, and follow-up through maintenance in our <a href=\"\/en\/sa\/media-center\/mall-fire-system-maintenance-contract\/\">mall fire maintenance contract<\/a> article.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ad58a2 elementor-widget elementor-widget-text-editor\" data-id=\"3ad58a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Does every mall need fire sprinklers?<\/h3><\/summary><p>The 2021 IBC requires them throughout covered and open malls. In Saudi Arabia the consultant and Civil Defense set the requirement under SBC 801.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which sprinkler suits hypermarket racks?<\/h3><\/summary><p>It depends on commodity, storage and ceiling height; the designer may choose storage or ESFR sprinklers instead of corridor sprinklers.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can a tenant move sprinklers on their own?<\/h3><\/summary><p>The revised drawing should be reviewed and approved by mall management, the work done by a specialist team and the section tested before opening.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Why is a mall sprinkler network zoned?<\/h3><\/summary><p>So the control room knows where a sprinkler operated, and one zone can be isolated for changes without shutting the whole mall.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are sprinklers enough for mall restaurant kitchens?<\/h3><\/summary><p>No. Cooking needs its own hood suppression system in addition to building sprinklers.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What does AZEIDK supply for mall sprinkler systems?<\/h3><\/summary><p>TYCO and Victaulic standard, concealed, storage and ESFR sprinklers, and fire pumps, with datasheets and submittals.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a55cd6 elementor-widget elementor-widget-text-editor\" data-id=\"4a55cd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Mall sprinklers are designed area by area: standard sprinklers for corridors and shops, storage sprinklers where racks rise, hood systems for kitchens, on a network zoned with supervised valves. After opening, reviewing tenant changes is what keeps coverage intact.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77a3909 elementor-widget elementor-widget-text-editor\" data-id=\"77a3909\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Designing or building a mall?<\/strong> Send us the drawings, area schedule and storage details, and we will prepare the sprinkler and pump selection with the submittal. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8a9998b elementor-widget elementor-widget-text-editor\" data-id=\"8a9998b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.iccsafe.org\/wp-content\/uploads\/Session-7-and-9-2021-IBC-Use-of-Fire-Sprinklers-and-Alarms.pdf\" rel=\"nofollow noopener\" target=\"_blank\">2021 IBC: Use of Fire Sprinklers and Alarms<\/a> (International Code Council)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Mall fire sprinkler systems: when they are required, sprinkler choice for corridors, shops and hypermarket racks, network zoning and tenant fit-out reviews.<\/p>\n","protected":false},"author":0,"featured_media":27627,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-27653","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=27653"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27653\/revisions"}],"predecessor-version":[{"id":29310,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27653\/revisions\/29310"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/27627"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=27653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=27653"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=27653"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=27653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}