{"id":27444,"date":"2026-11-20T14:24:59","date_gmt":"2026-11-20T11:24:59","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T11:33:45","modified_gmt":"2026-11-21T08:33:45","slug":"school-fire-alarm-system-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/school-fire-alarm-system-saudi\/","title":{"rendered":"Fire Alarm System for Schools: Detectors for Each Space, Voice Sounders and Campus Networking"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"27444\" class=\"elementor elementor-27444 elementor-27443 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-86c7c38 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"86c7c38\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95867cd elementor-widget elementor-widget-text-editor\" data-id=\"95867cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>fire alarm system for schools<\/strong> detects fire early in classrooms, labs, the canteen and halls, warns everyone in the building with a clear sound and a visual signal, starts the evacuation and reports to the security room. In Saudi Arabia it is designed to the Saudi Fire Code SBC 801 and Civil Defense requirements, and it works only as well as the detector choice for each space and its links to the other school systems.<\/p>\n<p>For how conventional and addressable systems compare, see our guide to choosing a <a href=\"\/en\/sa\/media-center\/fire-alarm-systems-saudi-arabia\/\">fire alarm system<\/a> for Saudi projects.<\/p>\n<p>This article covers the technical side: which devices to use and where. It complements our <a href=\"\/en\/sa\/media-center\/schools-educational-fire-safety-guide\/\">school and educational facility fire safety guide<\/a>, which covers general Civil Defense requirements. AZEIDK&#8217;s scope for this sector is on the <a href=\"\/en\/sa\/industries\/schools-universities\/\">schools and universities<\/a> page, and system details are on the <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm systems<\/a> page.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-67feb6e elementor-widget elementor-widget-text-editor\" data-id=\"67feb6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>A classroom, a science lab, a kitchen and a sports hall each need a detector suited to its conditions.<\/li><li>Addressable systems pinpoint the alarm location and are the practical choice for large schools and multi-building campuses.<\/li><li>Sounders must clearly exceed break-time and sports-hall noise, with visual alarms for students with hearing impairment.<\/li><li>Links to the school PA, gates and HVAC are defined in a cause and effect matrix and tested before handover.<\/li><li>Fewer false alarms start at design: detector type, protected manual call points and panel programming.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-285c4ed elementor-widget elementor-widget-text-editor\" data-id=\"285c4ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why a fire alarm system for schools is different<\/h2>\n<p>A school changes use through the day. During lessons students are spread across classrooms; at break they gather in courtyards and the canteen; at assemblies and events the theatre or multipurpose hall fills up. After hours the building may be almost empty. The alarm system has to work well in every one of these conditions.<\/p>\n<p>One school also combines spaces with very different hazards: light-hazard classrooms, science labs with chemicals and burners, a canteen or kitchen, a library and furniture stores, electrical and server rooms, and a high-ceiling sports hall. Occupants are mostly children and teenagers who rely on teachers to evacuate, so a fast, clear signal matters more than anything else.<\/p>\n<p>The binding reference in the Kingdom is the Saudi Fire Code SBC 801, part of the Saudi Building Code, together with what Civil Defense requires for drawings and approval. NFPA 72 is used as the technical reference for design, installation and testing details where the designer adopts it or the project documents call for it.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ecaa269 elementor-widget elementor-widget-text-editor\" data-id=\"ecaa269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Addressable or conventional: choosing the panel for a school<\/h2>\n<p>In a conventional system detectors are grouped into zones, and the panel only knows which zone is in alarm. In an addressable system every device has its own address on the loop, so the panel shows a message such as &#8220;Smoke detector, first floor, classroom 12&#8221;. In a school with dozens of classrooms and corridors, that difference saves minutes of searching in an emergency.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Project<\/th><th>Typical choice<\/th><th>What to check<\/th><\/tr><\/thead><tbody><tr><td>Kindergarten or small single-building school, two floors<\/td><td>Conventional or small addressable, per specification<\/td><td>Number of zones, ease of locating an alarm, consultant requirements<\/td><\/tr><tr><td>Middle or secondary school with several floors and labs<\/td><td>Addressable, one loop or more<\/td><td>Loop capacity, isolators, control points for other systems<\/td><\/tr><tr><td>School complex or university campus with several buildings<\/td><td>Networked addressable panels with repeaters<\/td><td>Network cable route between buildings, location of central monitoring<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The <a href=\"\/en\/sa\/products\/single-loop-16-zone-fire-panel\/\">Context Plus addressable fire alarm panels<\/a> available from AZEIDK include single-loop panels with 16 or 32 zones and ZFP panels with zone LEDs, plus <a href=\"\/en\/sa\/products\/xfp-networkable-repeater-panels-xfp510-16-con-xfp510-32-con\/\">XFP networkable repeater panels<\/a> for the security room or administration office. The right model follows a count of devices and control points, and each panel&#8217;s datasheet is reviewed before approval.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ef206f elementor-widget elementor-widget-text-editor\" data-id=\"6ef206f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The right detector for each school space<\/h2>\n<p>The most common mistake is one smoke detector type throughout the building. Optical smoke detectors work well in classrooms and corridors, but in the canteen or near lab burners they can cause repeated alarms from steam and fumes. The table summarises the usual choice; the designer makes the final call for each space.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Space<\/th><th>Usual detector<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Classrooms, corridors, offices<\/td><td>Optical smoke detector<\/td><td>Good response to slow, smouldering fires in furniture and paper<\/td><\/tr><tr><td>Science labs<\/td><td>Heat detector or multisensor, depending on the lab<\/td><td>Fumes and steam can trigger smoke detectors falsely<\/td><\/tr><tr><td>Canteen and kitchen<\/td><td>Fixed temperature and rate-of-rise heat detector<\/td><td>Coordinated with the hood suppression system where fitted<\/td><\/tr><tr><td>Sports hall and theatre with high ceilings<\/td><td>Beam detector<\/td><td>Covers a large area and is wall mounted, so it is easier to reach for maintenance<\/td><\/tr><tr><td>Library, book and furniture stores<\/td><td>Optical smoke detector<\/td><td>Higher fire load than classrooms, so early detection matters<\/td><\/tr><tr><td>Electrical and server rooms<\/td><td>Smoke detector; the server room may need special suppression<\/td><td>Reviewed with <a href=\"\/en\/sa\/solutions\/special-fire-suppression-systems\/\">special fire suppression systems<\/a><\/td><\/tr><\/tbody><\/table><\/div>\n<p>AZEIDK supplies Context Plus <a href=\"\/en\/sa\/products\/addressable-optical-smoke-detector-55000-685imc\/\">addressable optical smoke detectors<\/a>, heat and multisensor detectors, and the <a href=\"\/en\/sa\/products\/intelligent-auto-aligning-beam-detector-sa7100-100\/\">SA7100-100 auto-aligning beam detector<\/a> for halls. Spacing and quantities are calculated per space; the method is in our article on <a href=\"\/en\/sa\/media-center\/smoke-heat-detector-spacing-calculation\/\">smoke and heat detector spacing<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88e8c1d elementor-widget elementor-widget-text-editor\" data-id=\"88e8c1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Manual call points: close to exits, protected from misuse<\/h2>\n<p>The manual call point lets a teacher or guard report a fire they can see before smoke reaches a detector. Call points usually sit at exits and stair entrances on every floor, at an accessible height.<\/p>\n<p>The familiar school problem is students pressing them out of curiosity or as a prank, followed by an unnecessary evacuation. Usual measures: a listed clear protective cover lifted before operation, a dual-action model that needs two movements, and locations that teachers and supervisors can see. No cover may prevent real use, and the consultant must accept it.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97e61a7 elementor-widget elementor-widget-text-editor\" data-id=\"97e61a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Sounders, beacons and voice messages<\/h2>\n<p>An alarm nobody hears is useless. A closed classroom may need only a base or wall sounder, while sports halls and covered courtyards need louder devices and closer spacing, because students, balls and clapping raise the background level. The design rule is that the alarm must be clearly louder than normal noise in the space, and it is measured during testing.<\/p>\n<p>Visual alarms are needed where students with hearing impairment may be present and in noisy areas; coverage categories are explained in our article on <a href=\"\/en\/sa\/media-center\/fire-alarm-flasher-en-54-23-visual-alarm-devices\/\">EN 54-23 visual alarm devices<\/a>.<\/p>\n<p>A siren alone can confuse young children, so many schools prefer sounders that play a recorded message asking everyone to leave calmly by the nearest exit. Context Plus options include the <a href=\"\/en\/sa\/products\/addressable-voice-sounder-hi-output-deep-base-con446a-cx-dr\/\">CON446A addressable voice sounder<\/a> and combined sounder-beacon models. In large buildings the complete answer is a full voice alarm system, covered in <a href=\"\/en\/sa\/media-center\/voice-evacuation-alarm-systems\/\">voice evacuation systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5c340d elementor-widget elementor-widget-text-editor\" data-id=\"c5c340d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Linking the fire alarm to other school systems<\/h2>\n<p>On alarm, building systems must respond in a predefined way, written into the cause and effect matrix. Key items in schools:<\/p>\n<ul><li><strong>School PA:<\/strong> stop music and routine announcements so they do not mask the evacuation message.<\/li><li><strong>Gates and access control:<\/strong> release electrically locked doors and turnstiles on escape routes, as discussed in <a href=\"\/en\/sa\/media-center\/school-gates-turnstiles-student-attendance-saudi\/\">school and university gates<\/a>.<\/li><li><strong>Central HVAC:<\/strong> stop air handling units or start smoke control, per design.<\/li><li><strong>Lifts:<\/strong> recall to the exit level.<\/li><li><strong>Kitchen suppression:<\/strong> signal the fire alarm panel when it discharges.<\/li><\/ul>\n<p>Every line in the matrix needs a control or monitoring point on the panel, so they are counted early when the panel and loop capacity are chosen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61a37e3 elementor-widget elementor-widget-text-editor\" data-id=\"61a37e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>University campuses and school complexes: networked panels<\/h2>\n<p>On a campus with several buildings, each building usually gets its own panel and the panels are networked so the security centre sees every building from one place. Repeater panels at building entrances or supervisors&#8217; offices display alarms and allow silencing according to access levels.<\/p>\n<p>The network cable route between buildings is planned so a fault in one building does not isolate the rest, with a loop topology where the panel supports it. The fire alarm network stays separate from the university data network; campus networks are covered in <a href=\"\/en\/sa\/media-center\/university-campus-networks-wifi-fiber-saudi\/\">university campus networks<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba73889 elementor-widget elementor-widget-text-editor\" data-id=\"ba73889\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>False alarms in schools: causes and fixes<\/h2>\n<p>Frequent false alarms teach students and staff to ignore a real one. Common causes in schools:<\/p>\n<ul><li>A smoke detector in a lab or kitchen instead of a heat detector.<\/li><li>Dust from holiday maintenance and painting without temporarily isolating detectors.<\/li><li>Air fresheners or experiment smoke near a detector.<\/li><li>Students tampering with call points.<\/li><li>Dirty detectors not cleaned for years.<\/li><\/ul>\n<p>The fix combines correct detector selection, periodic cleaning and a log of the cause of every alarm. Addressable panels also report detector contamination, as explained in <a href=\"\/en\/sa\/media-center\/smoke-detector-sensitivity-testing-cleaning\/\">smoke detector sensitivity testing and cleaning<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a876ae elementor-widget elementor-widget-text-editor\" data-id=\"2a876ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation, approval and maintenance<\/h2>\n<p>A school fire alarm system goes through design and calculations with drawing approval, then supply and installation, then testing and commissioning with the consultant, then handover with documents. In existing schools, installation is best scheduled during holidays so work does not disrupt classes.<\/p>\n<p>After commissioning the system needs periodic inspection under an approved maintenance programme. See the schedule in <a href=\"\/en\/sa\/media-center\/fire-alarm-periodic-inspection-maintenance-saudi\/\">fire alarm maintenance<\/a>, and AZEIDK&#8217;s <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance contracts<\/a> and <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-308f5ee elementor-widget elementor-widget-text-editor\" data-id=\"308f5ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Which is better for schools, addressable or conventional fire alarm?<\/h3><\/summary><p>Addressable suits multi-floor schools and campuses because it pinpoints the alarm and makes integration easier. Conventional may be enough for a small building if the project specification accepts it.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Should a science lab have a smoke detector?<\/h3><\/summary><p>Usually not. Fumes and steam cause false alarms, so a heat or multisensor detector is chosen depending on the lab and the designer&#8217;s decision.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How do we stop students pressing the manual call point?<\/h3><\/summary><p>Use a listed protective cover or a dual-action model, place call points where teachers can see them, and brief students. No measure may block real use in a fire.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can the school bell act as the fire alarm?<\/h3><\/summary><p>No. The class bell and the normal PA are not a substitute for approved notification devices connected to the fire alarm panel. The PA can be linked so routine broadcasting stops on alarm.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which detector suits a high-ceiling sports hall?<\/h3><\/summary><p>Beam detectors are common because they cover a large area from wall-mounted units; the designer sets spacing based on ceiling height and shape.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When should an existing school install or upgrade its fire alarm?<\/h3><\/summary><p>During holidays, especially the summer break, so cabling, installation and testing do not disrupt classes, while the old system stays live until the new one is commissioned.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69fee0a elementor-widget elementor-widget-text-editor\" data-id=\"69fee0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>A school fire alarm system works when it is designed for each space: smoke detection in classrooms, heat in labs and kitchens, beam detection in halls, and a sound and message a young child understands. It then needs integration, testing and regular maintenance. These details cost far less to settle at design stage than after commissioning.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28b406a elementor-widget elementor-widget-text-editor\" data-id=\"28b406a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-related\">Related reading: <a href=\"\/en\/sa\/media-center\/government-buildings-fire-alarm-systems\/\">Fire Alarm Systems for Government Buildings<\/a>, <a href=\"\/en\/sa\/media-center\/fire-alarm-record-of-completion-sprinkler-test-certificate\/\">Fire Alarm Record of Completion and Sprinkler Material and Test Certificate<\/a> and <a href=\"\/en\/sa\/media-center\/auto-workshop-fire-alarm-heat-detectors\/\">Fire Alarm in Car Workshops<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6acdc19 elementor-widget elementor-widget-text-editor\" data-id=\"6acdc19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Planning a fire alarm for a school or campus?<\/strong> Send us the drawings and the number of buildings and floors, and the AZEIDK team will propose a detector and panel layout with the datasheet for each device. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab5265b elementor-widget elementor-widget-text-editor\" data-id=\"ab5265b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-72-standard-development\/72\" rel=\"noopener\" target=\"_blank\">NFPA 72: National Fire Alarm and Signaling Code<\/a> (NFPA), <a href=\"\/en\/sa\/media-center\/schools-educational-fire-safety-guide\/\" rel=\"noopener\" target=\"_blank\">School and Educational Facility Fire Safety<\/a> (AZEIDK), and Context Plus product pages on the AZEIDK website.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire alarm system for schools in Saudi Arabia: addressable panels, detectors for classrooms, labs, canteens and halls, voice sounders and PA and gate links.<\/p>\n","protected":false},"author":0,"featured_media":27287,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-27444","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27444","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=27444"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27444\/revisions"}],"predecessor-version":[{"id":28334,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27444\/revisions\/28334"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/27287"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=27444"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=27444"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=27444"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=27444"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}