{"id":27100,"date":"2026-11-20T13:33:28","date_gmt":"2026-11-20T10:33:28","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-22T10:40:42","modified_gmt":"2026-11-22T07:40:42","slug":"fire-door-closer-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-door-closer-saudi\/","title":{"rendered":"Fire Door Closer: Why Fire Doors Must Self-Close, How to Size the Closer and How to Adjust It"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"27100\" class=\"elementor elementor-27100 elementor-27099 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-564e70d e-con-full az-el-article e-flex e-con e-parent\" data-id=\"564e70d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c7f18d1 elementor-widget elementor-widget-text-editor\" data-id=\"c7f18d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>fire door closer<\/strong> returns the door to the closed position after every opening, so the door can do its job as a barrier to fire and smoke. An open fire door is worth nothing, which is why references require every fire door to be self-closing, using a closer listed for fire doors or listed spring hinges.<\/p>\n<p>This article covers why the closer is required, how to size it to door width and weight, the limits on closing speed and opening force, why mechanical hold-open arms are not allowed, and the faults inspectors look for.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aed1a8 elementor-widget elementor-widget-text-editor\" data-id=\"2aed1a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>Every swinging fire door needs a listed closer or listed ANSI\/BHMA Grade 1 spring hinges, plus a self-latching device.<\/li><li>Mechanical hold-open is not permitted on fire doors; a magnetic holder released by the fire alarm is the accepted option.<\/li><li>EN 1154 grades closer power from size 1 to 7 by leaf width and weight; where they differ, use the larger size.<\/li><li>Closing from 90 to 12 degrees should take at least 5 seconds under accessibility requirements.<\/li><li>Pairs of doors need a closing device on each leaf.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c1609e elementor-widget elementor-widget-text-editor\" data-id=\"7c1609e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why is a fire door closer required?<\/h2>\n<p>A 60- or 90-minute rating assumes the door is closed and latched during a fire. NFPA 80 groups fire door operation into self-closing (a standard mechanical closer), automatic-closing (held open and released on alarm) and power-operated. SDI-118 states that each fire door needs either listed ANSI\/BHMA Grade 1 spring hinges or a listed closer, and that every swinging fire door must have a listed and labelled self-latching device.<\/p>\n<p>The closer is part of the rated assembly, not an optional accessory. For other exit door hardware, see our <a href=\"\/en\/sa\/media-center\/emergency-exit-door-guide-saudi\/\">emergency exit door guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63c52fc elementor-widget elementor-widget-text-editor\" data-id=\"63c52fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to tell a closer is suitable for fire doors<\/h2>\n<ul><li><strong>US references:<\/strong> a listing for use on fire doors, such as the UL 10C listing LCN states for its closers, the positive pressure fire test standard for door assemblies.<\/li><li><strong>European references:<\/strong> the six-digit EN 1154 code, whose fourth digit covers fire behaviour: 1 means suitable for fire and smoke door assemblies, 0 means not approved for them.<\/li><\/ul>\n<p>An unlisted closer may work well day to day, but it will not be accepted on a rated door at submittal or inspection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-855dfd9 elementor-widget elementor-widget-text-editor\" data-id=\"855dfd9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to size a fire door closer<\/h2>\n<table><thead><tr><th>Power size<\/th><th>Recommended leaf width<\/th><th>Test door mass<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>750 mm<\/td><td>20 kg<\/td><\/tr><tr><td>2<\/td><td>850 mm<\/td><td>40 kg<\/td><\/tr><tr><td>3<\/td><td>950 mm<\/td><td>60 kg<\/td><\/tr><tr><td>4<\/td><td>1100 mm<\/td><td>80 kg<\/td><\/tr><tr><td>5<\/td><td>1250 mm<\/td><td>100 kg<\/td><\/tr><tr><td>6<\/td><td>1400 mm<\/td><td>120 kg<\/td><\/tr><tr><td>7<\/td><td>1600 mm<\/td><td>160 kg<\/td><\/tr><\/tbody><\/table>\n<p>If width and weight fall in different sizes, use the larger. The widths assume a standard installation; tall, windy, draughty or external doors may need a larger size. Steel fire doors are usually heavier than ordinary timber doors of the same width, so do not size on width alone.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3d8a9f elementor-widget elementor-widget-text-editor\" data-id=\"a3d8a9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Closing speed and opening force<\/h2>\n<ul><li><strong>Closing time:<\/strong> ICC A117.1 and the 2010 ADA Standards require at least 5 seconds for the door to move from 90 degrees to 12 degrees from the latch.<\/li><li><strong>Opening force:<\/strong> fire doors are exempt from the 5 lbf (about 22 N) limit for ordinary interior doors and are subject to the minimum force allowed by the authority having jurisdiction. The IBC allows 30 lbf (about 133 N) to set a fire door in motion and 15 lbf (about 67 N) to open it fully.<\/li><\/ul>\n<p>On site, the closer is adjusted so the door closes fully and latches from any opening angle, without slamming and without stopping short.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80fbd8c elementor-widget elementor-widget-text-editor\" data-id=\"80fbd8c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Can the closer hold a fire door open?<\/h2>\n<p>No. SDI-118 states that mechanical hold-open devices are not permitted on self-closing doors, and LCN confirms mechanical hold-open options are not allowed on fire-rated doors. The accepted option is a magnetic holder or closer that releases when the fire alarm activates, tested during system checks. See <a href=\"\/en\/sa\/media-center\/magnetic-door-holder-fire-alarm\/\">magnetic door holders with fire alarm release<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06f9285 elementor-widget elementor-widget-text-editor\" data-id=\"06f9285\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Pairs of doors<\/h2>\n<p>SDI-118 requires closing devices on both leaves of a pair, with the authority having jurisdiction able to allow omission on the inactive leaf of equipment rooms. Both leaves must latch when closed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac954aa elementor-widget elementor-widget-text-editor\" data-id=\"ac954aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Faults inspectors look for<\/h2>\n<ul><li>The door does not close fully or latch from full open.<\/li><li>The arm is detached, or the closer has been removed.<\/li><li>The door is wedged or tied open.<\/li><li>Oil leaking from the closer body, a sign it needs replacement.<\/li><li>A replacement closer not listed for fire doors.<\/li><li>Slamming from poor adjustment, which damages frame and latch over time.<\/li><\/ul>\n<p>These are part of periodic fire door checks; see <a href=\"\/en\/sa\/media-center\/fire-rated-doors-inspection-maintenance\/\">fire door inspection and maintenance to NFPA 80<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9f5f77 elementor-widget elementor-widget-text-editor\" data-id=\"a9f5f77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Closer checklist at order and handover<\/h2>\n<ol><li>Confirm the door schedule lists a closer for every fire door, or listed spring hinges where those are the approved alternative.<\/li><li>Ask for the closer datasheet and check the fire door listing or the fourth digit of the EN 1154 code.<\/li><li>Set the power size from the actual leaf width and weight, not width alone.<\/li><li>Choose a mounting type that suits the swing and closer position within the door&#8217;s listing.<\/li><li>Where doors are kept open in working hours, specify an alarm-released magnetic holder instead of any mechanical hold-open.<\/li><li>At handover, open each door fully and let go: it must close and latch unaided, without slamming.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c693082 elementor-widget elementor-widget-text-editor\" data-id=\"c693082\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire doors and hardware from AZEIDK<\/h2>\n<p>Under its <a href=\"\/en\/sa\/solutions\/fire-rated-doors-emergency-exit-solutions\/\">fire-rated doors and emergency exit solutions<\/a>, AZEIDK supplies <a href=\"\/en\/sa\/products\/fire-rated-steel-doors\/\">Falcon Gold steel fire doors<\/a> with the hardware set in the door schedule, installs them, checks after installation that each door self-closes fully and latches, and follows up under <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">maintenance contracts<\/a>. See also <a href=\"\/en\/sa\/media-center\/fire-rated-doors-saudi\/\">how to order and accept fire-rated doors<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ae3977 elementor-widget elementor-widget-text-editor\" data-id=\"8ae3977\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What does a door closer do on a fire door?<\/h3><\/summary><p>It returns the door to closed after each opening. It is required because the fire rating assumes the door is closed and latched during a fire.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can spring hinges replace the closer?<\/h3><\/summary><p>SDI-118 accepts listed ANSI\/BHMA Grade 1 spring hinges instead of a closer, if they are within the door&#8217;s listing.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can a fire door be kept open?<\/h3><\/summary><p>Only with a magnetic holder that releases automatically on fire alarm. Wedges and mechanical hold-open are not allowed.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which closer size suits a 1,000 mm door?<\/h3><\/summary><p>Under EN 1154 the width falls between size 3 and size 4, so size 4, or larger if the door weighs over 80 kg.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How long should a fire door take to close?<\/h3><\/summary><p>At least 5 seconds from 90 to 12 degrees under accessibility requirements, ending fully closed and latched.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e47169b elementor-widget elementor-widget-text-editor\" data-id=\"e47169b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>The closer is part of the door&#8217;s rating. Choose a listed closer sized for width and weight, adjust it to close and latch without slamming, and hold doors open only with alarm-released magnets.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa1ec2c elementor-widget elementor-widget-text-editor\" data-id=\"fa1ec2c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Fire doors not closing properly?<\/strong> Send us the number and location of doors and we will arrange an inspection of doors and hardware under a maintenance contract. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-324fb78 elementor-widget elementor-widget-text-editor\" data-id=\"324fb78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/steeldoor.org\/sdi-118\/\" rel=\"noopener\" target=\"_blank\">SDI-118<\/a> (Steel Door Institute); <a href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/lcn\/information-documents\/LCN_Fire-rated_Door_Closers_Article_116471.pdf\" rel=\"noopener\" target=\"_blank\">Fire-rated Door Closers<\/a> (LCN, Allegion); <a href=\"https:\/\/idighardware.com\/2012\/05\/decoded-opening-force-and-closing-speed\/\" rel=\"noopener\" target=\"_blank\">Decoded: Opening Force and Closing Speed<\/a> (iDigHardware); <a href=\"https:\/\/www.firesafe.org.uk\/explanation-of-the-coding-system-for-fire-door-closers-in-bs-en-1154-1997\/\" rel=\"noopener\" target=\"_blank\">Explanation of the Coding System for Fire Door Closers in BS EN 1154<\/a> (Firesafe.org.uk).<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>A fire door closer is part of the door&#8217;s rating: fire listing, EN 1154 power sizes 1 to 7, a 5 second closing time and why mechanical hold-open is banned.<\/p>\n","protected":false},"author":0,"featured_media":29062,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-27100","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27100","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=27100"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27100\/revisions"}],"predecessor-version":[{"id":27176,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/27100\/revisions\/27176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29062"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=27100"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=27100"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=27100"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=27100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}