{"id":25295,"date":"2026-11-15T11:34:00","date_gmt":"2026-11-15T08:34:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-15T11:34:57","modified_gmt":"2026-11-15T08:34:57","slug":"ul-listed-fire-extinguisher-ratings-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/ul-listed-fire-extinguisher-ratings-saudi\/","title":{"rendered":"UL Listed Fire Extinguisher Ratings: 2-A:10-B:C vs EN 3 13A\/89B in Saudi Arabia"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"25295\" class=\"elementor elementor-25295 elementor-25294 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-131a617 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"131a617\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a0241af elementor-widget elementor-widget-text-editor\" data-id=\"a0241af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A UL listed fire extinguisher is a model that UL Solutions has tested and rated to ANSI\/UL 711, with the rating printed on the label in a form such as 2-A:10-B:C. European extinguishers are rated to EN 3 in a form such as 13A\/89B, and there is no official conversion between the two systems. In Saudi Arabia a UL mark alone is not enough: the extinguisher also needs a valid certificate of conformity under the SASO Technical Regulation for Fire Control Materials and Equipment.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff400dc elementor-widget elementor-widget-text-editor\" data-id=\"ff400dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>The number before A or B in a UL rating reflects the size of the test fire the extinguisher put out. A higher number means more extinguishing capability.<\/li>\n<li>The C in a UL rating has no number. It means the agent did not conduct electricity in the test.<\/li>\n<li>Under EN 3 an extinguisher is classified by its rating, not its weight or size. A smaller unit that meets 13A is just as effective as a larger 13A unit.<\/li>\n<li>No formula converts 2-A into 13A. Compare against the code adopted for the project and the datasheet.<\/li>\n<li>The Saudi technical regulation requires a certificate of conformity before extinguishing equipment is placed on the market, and it does not name UL as a substitute.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e80ba99 elementor-widget elementor-widget-text-editor\" data-id=\"e80ba99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What does a UL listed fire extinguisher mean?<\/h2>\n<p>UL Listed means the extinguisher model was tested by UL Solutions, appears in its listings, and is built under UL&#8217;s ongoing factory follow-up. The rating and fire test standard is ANSI\/UL 711, published as an identical standard with the Canadian CAN\/ULC-S508. It covers rating and fire-test performance for Class A, B, C, D and K fires.<\/p>\n<p>NFPA 10 (2018 edition), Section 4.1.1, states that portable fire extinguishers used to comply with the standard shall be listed and labeled, and shall meet ANSI\/UL 711 and CAN\/ULC-S508. That is why consultants on projects designed to NFPA 10 ask for UL listed extinguishers, or an equivalent that the project code accepts. For distribution and inspection rules, see our <a href=\"\/en\/sa\/media-center\/nfpa-10-portable-fire-extinguishers-guide\/\">NFPA 10 portable fire extinguishers guide<\/a>. This reference is to the 2018 edition as cited by the source; newer editions have been issued since, the latest being the 2026 edition, so check the section number in the edition your project uses.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45d40cd elementor-widget elementor-widget-text-editor\" data-id=\"45d40cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How do you read a UL rating such as 2-A:10-B:C?<\/h2>\n<p>The label combines three parts, and each comes from a different test in UL 711.<\/p>\n<h3>The A part: ordinary combustibles<\/h3>\n<p>The Class A number comes from comparative fire tests on wood cribs and wood panels of different sizes. The rating table in the standard runs from 1-A to 40-A. Ratings from 1-A to 6-A need both crib and panel tests, while 10-A and above need crib tests only. In practice, a 4-A unit has passed a larger test fire than a 2-A unit.<\/p>\n<h3>The B part: flammable liquids<\/h3>\n<p>Class B is tested on square pans of flammable liquid. UL 711 states that the Class B rating equals 40 percent of the fire area consistently extinguished by an expert operator. From the pan table: the 1-B pan is 2.5 ft\u00b2 (0.23 m\u00b2) and the 20-B pan is 50 ft\u00b2 (4.65 m\u00b2). So a 10-B unit has put out a much larger pan fire in testing than a 1-B unit.<\/p>\n<h3>The C part: energized electrical equipment<\/h3>\n<p>Class C carries no number. The UL 711 Class C test checks that the agent is electrically nonconductive, and no fire tests on electrical fires are run. To pass, there must be no visible breakdown and current must not rise above 1.0 mA. A C rating tells you the agent is safe on live equipment. It does not measure fire size.<\/p>\n<h3>Class K: cooking oils<\/h3>\n<p>Class K also has no number. It is tested on a fryer with vegetable oil, and the fire must go out with no re-ignition for at least 20 minutes and no splashing of burning oil.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0781957 elementor-widget elementor-widget-text-editor\" data-id=\"0781957\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How do you read an EN 3 rating such as 13A\/89B?<\/h2>\n<p>The EN 3 series sets the characteristics, performance and test methods for portable extinguishers, and EN 3-7 covers classification and fire tests for Classes A and B. Class A tests use burning wooden cribs, and Class B tests use trays of flammable liquid. The number in 13A or 89B indicates the size of the test fire, so a bigger number means a bigger fire put out.<\/p>\n<p>London Fire Brigade guidance makes two useful points for buyers. Extinguishers are classified by rating, not by size, weight or litres of content, and a smaller unit that meets 13A is just as effective. It also gives the example of a 2.5 kg CO2 extinguisher rated 34B. EN 3 also includes Class F for cooking oils, shown as for example 15F.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23ae7d7 elementor-widget elementor-widget-text-editor\" data-id=\"23ae7d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>UL 711 vs EN 3: side-by-side<\/h2>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Item<\/th><th>UL 711 \/ CAN\/ULC-S508<\/th><th>EN 3 (EN 3-7 for rating)<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Rating format<\/td><td>2-A:10-B:C<\/td><td>13A\/89B (F may be added for cooking oils)<\/td><\/tr>\n<tr><td>Ordinary combustibles test<\/td><td>Wood cribs and panels, 1-A to 40-A<\/td><td>Wooden cribs; the number indicates test fire size<\/td><\/tr>\n<tr><td>Flammable liquids test<\/td><td>Square pans; rating is 40% of the area an expert operator puts out<\/td><td>Liquid trays; the number indicates test fire size<\/td><\/tr>\n<tr><td>Electrical equipment<\/td><td>C with no number, after a nonconductivity test<\/td><td>No numeric electrical class; check the manufacturer&#8217;s label and datasheet<\/td><\/tr>\n<tr><td>Cooking oils<\/td><td>Class K, no number<\/td><td>Class F with a number, such as 15F<\/td><\/tr>\n<tr><td>Usually required by<\/td><td>NFPA 10 and projects designed to US references<\/td><td>Projects designed to European and British references<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Note that the letter C means different things. In UL it stands for energized electrical equipment, while in the European fire classes it refers to gas fires. Do not compare the letters one to one.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4e0d3e elementor-widget elementor-widget-text-editor\" data-id=\"d4e0d3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Can 2-A be converted to 13A?<\/h2>\n<p>No official formula converts a UL rating into an EN 3 rating or back, because the test fires and methods differ. Start from the reference the designer and Civil Defense adopted for the project, then pick an extinguisher rated to that reference at the rating the distribution tables call for. If the drawings follow NFPA 10, the tables use UL units such as 2-A and 10-B, and a unit rated only 13A needs the consultant&#8217;s approval. For a first estimate of quantities, try our <a href=\"\/en\/sa\/tools\/fire-extinguisher-calculator\/\">fire extinguisher calculator<\/a>, then have an engineer review the result.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fb6b4e elementor-widget elementor-widget-text-editor\" data-id=\"9fb6b4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What applies to fire extinguishers in Saudi Arabia?<\/h2>\n<p>The Saudi Fire Protection Code (SBC 801) and Civil Defense decide which buildings need extinguishers and how they are distributed. NFPA 10 is the common technical reference for selection and distribution, and the applicable edition is set by the code and the authority on each project.<\/p>\n<p>Placing an extinguisher on the market is governed by the SASO Technical Regulation for Fire Control Materials and Equipment. It states that equipment in scope shall not be placed on the market without a certificate of conformity from a SASO-approved body, under conformity assessment Type 3, with a technical file that includes the supplier&#8217;s declaration of conformity. Its annex of standards lists GSO ISO 7165 for portable extinguishers. The regulation does not mention UL, so a UL mark is not a substitute for Saudi conformity. It also states that the updated product and customs code listings are those published on the SABER platform.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d7ef5a elementor-widget elementor-widget-text-editor\" data-id=\"1d7ef5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to check that an extinguisher is really UL listed<\/h2>\n<ol>\n<li>Read the label. It should show the full rating, such as 2-A:10-B:C, the listing mark and the model number.<\/li>\n<li>Look the model up in UL Product iQ, UL Solutions&#8217; source for certification information. The method is the same as in our guide on <a href=\"\/en\/sa\/media-center\/fire-pump-ul-fm-approval-check\/\">checking UL and FM approval for fire pumps<\/a>.<\/li>\n<li>Match the datasheet to the label: weight, agent, rating and operating temperature range must agree.<\/li>\n<li>Ask for the valid Saudi certificate of conformity for the same model and check its expiry. A certificate in an old approval file does not prove it is valid today.<\/li>\n<li>Do not accept &#8220;UL Approved&#8221; or &#8220;UL Standard&#8221; in a catalogue without a listing you can verify.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ffd038 elementor-widget elementor-widget-text-editor\" data-id=\"0ffd038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire extinguishers available from AZEIDK<\/h2>\n<p>AZEIDK supplies <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguishers<\/a> in Saudi Arabia, including the Falcon Gold range of dry powder, CO2 and foam units. Ratings and approvals vary by model, so we send the datasheet and the available conformity certificate for each model before approval, and we do not describe any model as UL listed unless its listing can be verified. For the differences between types, see <a href=\"\/en\/sa\/media-center\/falcon-gold-fire-extinguishers-types\/\">Falcon Gold fire extinguisher types<\/a>, and for servicing see <a href=\"\/en\/sa\/media-center\/fire-extinguisher-maintenance-refill\/\">fire extinguisher maintenance and refilling<\/a>.<\/p>\n<h3>What drives the cost of a UL listed extinguisher?<\/h3>\n<ul>\n<li>The approval the specification calls for: UL, EN 3 or another.<\/li>\n<li>The rating needed at each location. A higher rating means a larger unit or a more effective agent.<\/li>\n<li>The agent: dry powder, CO2, foam or wet chemical.<\/li>\n<li>Quantity, cabinets and brackets, and installation and signage needs.<\/li>\n<li>The maintenance contract after handover.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-174db7d elementor-widget elementor-widget-text-editor\" data-id=\"174db7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>What is a UL listed fire extinguisher?<\/h3><\/summary><p>It is an extinguisher model tested by UL Solutions to ANSI\/UL 711 and included in its listings, with ongoing factory follow-up. Its rating appears on the label in a form such as 2-A:10-B:C.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What does 2-A:10-B:C mean?<\/h3><\/summary><p>2-A is the capability on ordinary combustibles, 10-B the capability on flammable liquids from the pan test, and C means the agent is nonconductive. The numbers are relative: higher means more capability.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is a 13A extinguisher equal to a 2-A extinguisher?<\/h3><\/summary><p>There is no official equivalence because the two standards use different tests. Follow the reference the designer adopted, and get the consultant&#8217;s approval for any substitute.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is a UL certificate enough to sell an extinguisher in Saudi Arabia?<\/h3><\/summary><p>No. The SASO Technical Regulation for Fire Control Materials and Equipment requires a certificate of conformity from a SASO-approved body and does not name UL as a substitute.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What is the difference between a UL and a UL\/FM fire extinguisher?<\/h3><\/summary><p>UL tests and lists extinguishers to UL 711. FM Approvals is a separate approval body. If a model claims both, check each body&#8217;s own database, not the catalogue.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How do I verify a UL listed fire extinguisher in Saudi Arabia?<\/h3><\/summary><p>Match the model number on the label against UL Product iQ, then ask the supplier for the datasheet and the valid Saudi certificate of conformity for the same model.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-729ff3b elementor-widget elementor-widget-text-editor\" data-id=\"729ff3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>A UL rating such as 2-A:10-B:C and an EN 3 rating such as 13A\/89B measure extinguishing capability in two different ways, and no fixed number converts one into the other. Choose the extinguisher to the reference adopted for your project, verify the listing in the issuing body&#8217;s database, and do not accept delivery without a valid Saudi certificate of conformity.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41edbe8 elementor-widget elementor-widget-text-editor\" data-id=\"41edbe8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need extinguishers with a specific rating for your project?<\/strong> Send the extinguisher schedule or drawings and we will check the required ratings and propose available models with datasheets and certificates. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d2f37b7 elementor-widget elementor-widget-text-editor\" data-id=\"d2f37b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/law.resource.org\/pub\/us\/cfr\/ibr\/inc\/ul\/ul.s711.7.2013.pdf\" rel=\"nofollow noopener\" target=\"_blank\">ANSI\/UL 711 and CAN\/ULC-S508, 7th edition (December 2004, reaffirmed 2013), Sections 5.2, 5.4, 5.5, 5.7, 9.1, 11.1 and Tables 2 and 5<\/a>; <a href=\"https:\/\/efcog.org\/wp-content\/uploads\/Wgs\/Operations%20Working%20Group\/_Engineering%20Practices%20Subgroup2\/Fire%20Protection%20Task%20Team\/Documents\/NFPA%20Code%20Reviews\/NFPA%2010%20Code%20Review%20%282018%20Edition%29.pdf\" rel=\"nofollow noopener\" target=\"_blank\">EFCOG review of NFPA 10, 2018 edition, Section 4.1.1<\/a>; <a href=\"https:\/\/london-fire.gov.uk\/media\/7157\/gn_08_lf_format.pdf\" rel=\"nofollow noopener\" target=\"_blank\">London Fire Commissioner, Fire Safety Guidance Note GN08, Rev 19, September 2022<\/a>; <a href=\"https:\/\/saso.gov.sa\/en\/Laws-And-Regulations\/Technical_regulations\/Documents\/TR%20-%20Fire%20Control%20Materials%20and%20Equipment.pdf\" rel=\"nofollow noopener\" target=\"_blank\">SASO: Technical Regulation for Fire Control Materials and Equipment<\/a>; <a href=\"https:\/\/productiq.ulprospector.com\" rel=\"nofollow noopener\" target=\"_blank\">UL Solutions: Product iQ<\/a>; <a href=\"https:\/\/www.ifsecglobal.com\/?p=556255\" rel=\"nofollow noopener\" target=\"_blank\">IFSEC Global: LPCB scheme manager on EN 3 testing<\/a>.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>UL listed fire extinguisher ratings explained: 2-A:10-B:C under UL 711, how EN 3 13A\/89B differs, and how to verify listing and SASO conformity in KSA.<\/p>\n","protected":false},"author":0,"featured_media":25237,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-25295","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=25295"}],"version-history":[{"count":2,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25295\/revisions"}],"predecessor-version":[{"id":26222,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25295\/revisions\/26222"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/25237"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=25295"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=25295"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=25295"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=25295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}