{"id":25229,"date":"2026-11-14T16:38:32","date_gmt":"2026-11-14T13:38:32","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-14T16:38:35","modified_gmt":"2026-11-14T13:38:35","slug":"fire-alarm-symbols-legend-drawings","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-alarm-symbols-legend-drawings\/","title":{"rendered":"Fire Alarm Symbols on Drawings: Legend, Layout Plan and Riser for Civil Defense and Shop Drawings"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"25229\" class=\"elementor elementor-25229 elementor-25228 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5dc90 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"0e5dc90\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-52bc247 elementor-widget elementor-widget-text-editor\" data-id=\"52bc247\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Fire alarm symbols<\/strong> are how a fire alarm system is written on a drawing. Every detector, manual call point, sounder, strobe, panel and module appears as a short symbol, explained in the legend on the first sheet. NFPA 170 is the recognised reference, but the project&#8217;s own legend sets the exact shape, so never read a drawing without it.<\/p>\n<p>This guide covers what a legend contains, how to read common symbols, layout plan versus riser, and what reviewers check before approval. At the drawing stage, these items are part of AZEIDK&#8217;s <a href=\"\/en\/sa\/services\/shop-drawings-coordination\/\">shop drawings and coordination<\/a> service.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a5787a elementor-widget elementor-widget-text-editor\" data-id=\"1a5787a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>NFPA 170 (Standard for Fire Safety and Emergency Symbols) has a full chapter on symbols for electronic fire and smoke detection and notification system drawings. The latest edition listed by the NSAI standards store is 2024, which replaced the 2021 edition.<\/li><li>According to Security Sales &amp; Integration&#8217;s summary of the NFPA 72 shop drawing section, drawings should carry a device legend and symbols per NFPA 170, or other symbols the authority having jurisdiction accepts.<\/li><li>There is no single mandatory shape for every symbol on every project. The final reference for reading a drawing is the legend in that project&#8217;s file.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-39d3e1f elementor-widget elementor-widget-text-editor\" data-id=\"39d3e1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What are fire alarm symbols, and why does a drawing need a legend?<\/h2>\n<p>A fire alarm drawing sits over the architectural floor plan and can carry hundreds of devices. Each device type therefore gets a small symbol, and all of them are explained in one table: the fire alarm legend. It usually sits on the first sheet of the set or on a dedicated symbols and notes sheet.<\/p>\n<p>Quantities are priced from the legend, technicians install from it and reviewers check the specification against it. Any ambiguity in it ends up on site.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e7066b elementor-widget elementor-widget-text-editor\" data-id=\"3e7066b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is NFPA 170 and how does it relate to fire alarm symbols?<\/h2>\n<p>NFPA 170, Standard for Fire Safety and Emergency Symbols, collects the symbols used in fire safety and emergency work. The latest edition listed by the NSAI standards store is the 2024 edition, and its table of contents is organised by use, including:<\/p>\n<ul><li>Chapter 6: symbols for architectural and engineering drawings and insurance diagrams.<\/li><li>Chapter 7: symbols for water supply, extinguishing and sprinkler system drawings.<\/li><li>Chapter 8: symbols for electronic fire and smoke detection and notification system drawings. This is the chapter for fire alarm drawings.<\/li><li>Chapter 9: symbols for preincident planning sketches; Chapter 11: emergency evacuation diagrams and plans.<\/li><\/ul>\n<p>The link between the two standards comes from NFPA 72. According to Security Sales &amp; Integration&#8217;s review of Section 7.4 (shop drawings) in the 2016 edition of NFPA 72, drawings should include a device legend and symbols per NFPA 170, or other symbols the authority having jurisdiction accepts. NFPA 170 is the preferred set, but another set works if every symbol is defined in the legend and accepted by the reviewer.<\/p>\n<p>In Saudi Arabia the regulatory reference is the Saudi Fire Code SBC 801 and the General Directorate of Civil Defense requirements, with NFPA standards used as technical references by the designer. We found no Saudi text that fixes a symbol shape for each device.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64ef071 elementor-widget elementor-widget-text-editor\" data-id=\"64ef071\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What does a fire alarm legend contain?<\/h2>\n<p>A good legend is a multi-column table, not a list of pictures. Details vary by design office, but it usually includes:<\/p>\n<ul><li><strong>The symbol<\/strong> at the same size and shape used on the plans.<\/li><li><strong>The description<\/strong> in English and often Arabic, for example &#8220;Addressable Optical Smoke Detector&#8221;.<\/li><li><strong>The abbreviation<\/strong> used in notes, the riser and the bill of quantities.<\/li><li><strong>Mounting height or method<\/strong>: ceiling, wall at a stated height, in-duct, or above a false ceiling.<\/li><li><strong>Type notes<\/strong>: addressable or conventional, weatherproof (IP rating), candela rating for strobes.<\/li><li><strong>Cable and route symbols<\/strong>: cable type and size, loop routes, and short-circuit isolator positions.<\/li><\/ul>\n<p>Each legend item should match a line in the bill of quantities and the specification, so no device appears on a drawing without a price or a datasheet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29b2c1d elementor-widget elementor-widget-text-editor\" data-id=\"29b2c1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How do you read common fire alarm device symbols?<\/h2>\n<p>The table below reflects common market practice for how devices are drawn and abbreviated. It is not taken from the NFPA 170 tables, and abbreviations vary between designers, so use it as a general guide, never as a replacement for the project legend.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Device<\/th><th>How it usually appears on the plan<\/th><th>Common market abbreviations<\/th><\/tr><\/thead><tbody>\n<tr><td>Smoke detector<\/td><td>A small geometric shape (circle or square) with a letter or abbreviation for smoke<\/td><td>S, SD, OSD for optical<\/td><\/tr>\n<tr><td>Heat detector<\/td><td>Same detector shape with a letter for heat, sometimes separating fixed temperature from rate of rise<\/td><td>H, HD, ROR<\/td><\/tr>\n<tr><td>Multi-sensor detector<\/td><td>Detector symbol with a combined abbreviation<\/td><td>MS, OH<\/td><\/tr>\n<tr><td>Duct smoke detector<\/td><td>Detector symbol drawn on the duct run with its own abbreviation<\/td><td>DSD, DD<\/td><\/tr>\n<tr><td>Beam detector<\/td><td>Two symbols for transmitter and reflector or receiver, joined by a line for the beam<\/td><td>BD<\/td><\/tr>\n<tr><td>Manual call point (pull station)<\/td><td>Small square with a letter for manual operation, drawn on the wall next to exits<\/td><td>MCP, MPS, F<\/td><\/tr>\n<tr><td>Bell or sounder<\/td><td>Audible notification symbol on wall or ceiling<\/td><td>B, SND<\/td><\/tr>\n<tr><td>Strobe or horn-strobe<\/td><td>Notification symbol with the candela rating written beside it<\/td><td>V, HS, S\/V with cd value<\/td><\/tr>\n<tr><td>Fire alarm control panel<\/td><td>Rectangle or panel symbol with name and number<\/td><td>FACP, FAP, CIE<\/td><\/tr>\n<tr><td>Repeater or annunciator<\/td><td>Smaller panel symbol with a different abbreviation<\/td><td>RP, ANN<\/td><\/tr>\n<tr><td>Monitor (input) module<\/td><td>Small square on the loop beside the monitored device<\/td><td>MM, IM, IN<\/td><\/tr>\n<tr><td>Control (output) module<\/td><td>Small square with a note naming the controlled system<\/td><td>CM, OM, RM for relay<\/td><\/tr>\n<tr><td>Short-circuit isolator<\/td><td>Small symbol on the loop line between device groups<\/td><td>ISO<\/td><\/tr>\n<tr><td>End of line<\/td><td>Mark at the end of a conventional or notification circuit<\/td><td>EOL, EOLR<\/td><\/tr>\n<tr><td>Flow and tamper switch<\/td><td>Symbol on the sprinkler line linked to a monitor module<\/td><td>FS, TS, SV<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>For how these devices connect to the panel, see our <a href=\"\/en\/sa\/media-center\/fire-alarm-wiring-diagram\/\">fire alarm wiring diagram<\/a> guide.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-435ef74 elementor-widget elementor-widget-text-editor\" data-id=\"435ef74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How are cables, loops and addresses shown on the drawing?<\/h2>\n<p>The drawing also needs a convention for routes and addresses:<\/p>\n<ul><li><strong>Cable lines:<\/strong> each loop or circuit is drawn in a different line style or colour, with a note on cable type and size.<\/li><li><strong>Loop and address numbering:<\/strong> in addressable systems, the loop and device address are written next to each device and must match the panel programming.<\/li><li><strong>Zones:<\/strong> in conventional systems, zone boundaries are marked on the plan and the zone number is written on its devices.<\/li><li><strong>Isolators and end-of-line devices:<\/strong> shown clearly and checked against the riser.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b165de3 elementor-widget elementor-widget-text-editor\" data-id=\"b165de3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Layout plan or fire alarm riser diagram?<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>Layout plan<\/th><th>Riser diagram<\/th><\/tr><\/thead><tbody>\n<tr><td>What it shows<\/td><td>Position of every device on every floor, over the architectural plan<\/td><td>Vertical system sequence: panel, loops, floors, devices per floor<\/td><\/tr>\n<tr><td>Scale<\/td><td>Drawn to a stated scale<\/td><td>Usually schematic, not to scale<\/td><\/tr>\n<tr><td>What you check on it<\/td><td>Detector coverage, call points near exits, notification layout, cable routes<\/td><td>Device count per floor, loop split, isolator positions, interfaces and repeaters<\/td><\/tr>\n<tr><td>Use on site<\/td><td>Installation and fixing points<\/td><td>Quantity checks, programming and testing<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The review rule: each device count on a floor&#8217;s layout plan must equal the riser count for that floor and the bill of quantities.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1952a7 elementor-widget elementor-widget-text-editor\" data-id=\"d1952a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What do consultants and Civil Defense reviewers check on fire alarm drawings?<\/h2>\n<p>Review details vary with building type and reviewer. Based on the sources listed below on NFPA 72 drawing content, and on what consultants usually ask for, the main items are:<\/p>\n<ul><li>A complete legend, with every symbol on the plans defined once and without conflict.<\/li><li>A stated scale, north indicator, and room names and uses.<\/li><li>Walls, doors, partitions, and ceiling heights and shapes, because they affect detector layout.<\/li><li>Locations of the panel, repeaters and power supplies.<\/li><li>Notification devices with their ratings, and manual call points next to exits.<\/li><li>A riser that matches the layout, with battery and voltage drop calculations.<\/li><li>Interfaces with other systems: sprinklers, smoke control, lifts, emergency doors and HVAC, often through a cause and effect matrix.<\/li><\/ul>\n<p>For a wider checklist covering suppression and specifications see our <a href=\"\/en\/sa\/media-center\/fire-drawings-specifications-review-checklist\/\">fire drawings and specifications review checklist<\/a>, and for the full package submitted for approval see <a href=\"\/en\/sa\/media-center\/civil-defense-fire-design-drawings-package\/\">Civil Defense fire design drawings<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e05a53 elementor-widget elementor-widget-text-editor\" data-id=\"5e05a53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes in fire alarm symbols and drawings<\/h2>\n<ul><li><strong>A legend copied from an earlier project<\/strong> that lists devices not on this job, or misses ones that are.<\/li><li><strong>One abbreviation with two meanings<\/strong>, such as S for both smoke detector and sounder in the same set.<\/li><li><strong>No distinction between addressable and conventional<\/strong> on a mixed project, or between ceiling and duct detectors.<\/li><li><strong>Strobes without a candela rating<\/strong>, so coverage cannot be checked and the wrong model may be supplied.<\/li><li><strong>A design drawing sent to site as a shop drawing<\/strong> without coordination with the false ceiling, diffusers and lighting.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-646c82f elementor-widget elementor-widget-text-editor\" data-id=\"646c82f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How does AZEIDK prepare fire alarm shop drawings?<\/h2>\n<p>Under its shop drawings and coordination service, AZEIDK prepares shop drawings with device locations, cable routes and installation details, ready for consultant approval and coordinated with electrical, mechanical and architectural drawings so clashes are solved before installation. Issues are tracked in a revision register, and the set is handed over as built.<\/p>\n<p>The legend can be tied from the start to real devices from AZEIDK&#8217;s <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm systems<\/a> range, such as Context Plus addressable and conventional devices, so each symbol maps to a specific datasheet. For the differences between drawing stages, see <a href=\"\/en\/sa\/media-center\/fire-protection-shop-drawings\/\">fire protection shop drawings<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48fe7ae elementor-widget elementor-widget-text-editor\" data-id=\"48fe7ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Are fire alarm symbols the same on every drawing?<\/h3><\/summary><p>No. NFPA 170 is the recognised reference, but NFPA 72 also accepts other symbols the authority having jurisdiction approves. The practical reference for any drawing is its own legend.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the smoke detector symbol on a drawing?<\/h3><\/summary><p>It usually appears as a small geometric shape with S or SD inside, sometimes with a mark for optical or addressable. The exact shape is set by the project legend.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the fire alarm panel symbol?<\/h3><\/summary><p>The panel is usually a rectangle or panel symbol labelled FACP or a short name such as FAP, with a panel number on multi-panel projects.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a downloaded fire alarm symbols DWG file enough?<\/h3><\/summary><p>A ready-made symbol file is only a starting point. The legend is built for each project&#8217;s actual devices and the consultant&#8217;s requirements, so any downloaded file needs checking against the project devices and their datasheets before use.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04d0c84 elementor-widget elementor-widget-text-editor\" data-id=\"04d0c84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Fire alarm symbols only make sense with a complete legend. Start with the legend, read the layout, then match it against the riser and the bill of quantities. Close any undefined symbol or mismatched count on paper, before it reaches site.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6707a17 elementor-widget elementor-widget-text-editor\" data-id=\"6707a17\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need fire alarm shop drawings for your project?<\/strong> Send us the architectural drawings, the approved design and the system type, and we will prepare the shop drawings, legend and riser and coordinate them with the other trades. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-770b978 elementor-widget elementor-widget-text-editor\" data-id=\"770b978\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/shop.standards.ie\/en-ie\/standards\/nfpa-170-2024-829130_saig_nfpa_nfpa_3305218\" rel=\"noopener\" target=\"_blank\">NFPA 170:2024 Fire Safety and Emergency Symbols: table of contents<\/a> (NSAI Standards Store); <a href=\"https:\/\/www.securitysales.com\/insights\/shop-drawings-meet-nfpa-standards\/88574\/\" rel=\"noopener\" target=\"_blank\">How to Ensure Your Shop Drawings Meet NFPA Standards<\/a> (Security Sales &amp; Integration, on NFPA 72 2016 edition, Section 7.4); <a href=\"https:\/\/www.ecmag.com\/magazine\/articles\/article-detail\/documentation-is-essential--nfpa-72-s-chapter-7\" rel=\"noopener\" target=\"_blank\">Documentation Is Essential: NFPA 72&#8217;s Chapter 7<\/a> (Electrical Contractor); <a href=\"https:\/\/www.tn.gov\/content\/dam\/tn\/commerce\/documents\/fire_prevention\/posts\/AlarmShopDrawings.pdf\" rel=\"noopener\" target=\"_blank\">Fire Alarm Shop Drawing Requirements<\/a> (Tennessee State Fire Marshal&#8217;s Office)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire alarm symbols on drawings: what a legend contains, its NFPA 170 basis, how to read detector, panel and call point symbols, and layout plan vs riser.<\/p>\n","protected":false},"author":0,"featured_media":25219,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-25229","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25229","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=25229"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25229\/revisions"}],"predecessor-version":[{"id":25825,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25229\/revisions\/25825"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/25219"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=25229"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=25229"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=25229"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=25229"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}