{"id":25197,"date":"2026-11-14T16:13:24","date_gmt":"2026-11-14T13:13:24","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-14T16:13:24","modified_gmt":"2026-11-14T13:13:24","slug":"spare-sprinkler-head-box-cabinet-nfpa-13","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/spare-sprinkler-head-box-cabinet-nfpa-13\/","title":{"rendered":"Spare Sprinkler Head Box and Wrench: How Many Spares NFPA 13 Requires"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"25197\" class=\"elementor elementor-25197 elementor-25196 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f561281 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"f561281\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-41154ac elementor-widget elementor-widget-text-editor\" data-id=\"41154ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A spare sprinkler head box, or spare sprinkler cabinet, is a small cabinet kept on site with replacement sprinklers of the same types and temperature ratings as those installed, together with the right sprinkler wrench for each type. NFPA 13 sets a minimum stock by facility size: 6 spares for fewer than 300 installed sprinklers, 12 for 300 to 1,000, and 24 for more than 1,000.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fbe08e elementor-widget elementor-widget-text-editor\" data-id=\"4fbe08e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>The cabinet exists to put the sprinkler system back in service quickly after a head operates or is damaged.<\/li>\n<li>The minimum stock is 6, 12 or 24 heads, based on the total number of sprinklers installed in the facility.<\/li>\n<li>Spares must match the installed types and temperature ratings; an NFPA engineer advises at least two of each type.<\/li>\n<li>A sprinkler wrench in the cabinet is required, and each model has its own wrench named in the data sheet.<\/li>\n<li>Keep the cabinet on the premises where the temperature stays at or below 100\u00b0F (38\u00b0C) for ordinary sprinklers.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7cecaee elementor-widget elementor-widget-text-editor\" data-id=\"7cecaee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why does NFPA 13 require spare sprinklers on site?<\/h2>\n<p>A sprinkler that has operated in a fire cannot be reused. The same goes for one that leaks, is damaged or has been painted. While it is being replaced, part or all of the system is out of service because the control valve has to be shut. A matching head and its wrench on site cut that window to the minimum, instead of waiting for a delivery of the same model and rating.<\/p>\n<p>In Saudi Arabia the designer usually adopts NFPA 13 as the technical reference for sprinkler design and installation, so the spare cabinet appears in specifications and handover lists and the consultant checks it at handover. The number and condition of spares are also worth recording in the <a href=\"\/en\/sa\/media-center\/fire-safety-log-book-records-inspection\/\">fire safety log book<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a476000 elementor-widget elementor-widget-text-editor\" data-id=\"a476000\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How many heads does a spare sprinkler head box need under NFPA 13?<\/h2>\n<p>The count is based on the total sprinklers installed in the facility. The table below follows the article by NFPA fire protection engineer Brian O&#8217;Connor and matches the minimum table in Viking&#8217;s technical data for wrenches and cabinets.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d981b6 elementor-widget elementor-widget-text-editor\" data-id=\"4d981b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Sprinklers installed in the facility<\/th><th>Minimum spare sprinklers<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Fewer than 300<\/td><td>6<\/td><\/tr>\n<tr><td>300 to 1,000<\/td><td>12<\/td><\/tr>\n<tr><td>More than 1,000<\/td><td>24<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87d262d elementor-widget elementor-widget-text-editor\" data-id=\"87d262d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This is a minimum, not always enough. If a building has several types, for example uprights in plant rooms, recessed pendents in corridors and concealed heads in reception, each type needs its own spares. The NFPA article says the cabinet should hold at least two spares of each type, and Viking says the stock should include an adequate number of each type and temperature rating. In mixed-use buildings the real total can be well above the minimum.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9109a6 elementor-widget elementor-widget-text-editor\" data-id=\"e9109a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What goes inside a spare sprinkler cabinet?<\/h2>\n<ul>\n<li><strong>Matching heads:<\/strong> same model or SIN, K-factor, response, temperature rating and finish, since any difference changes how the head performs in the system.<\/li>\n<li><strong>A wrench for each type:<\/strong> the NFPA article states that NFPA 13 requires a sprinkler wrench in the cabinet, and Viking calls for a wrench of the appropriate type.<\/li>\n<li><strong>A list of installed sprinklers:<\/strong> the NFPA article says the number and type of installed sprinklers must be posted in the cabinet. We suggest listing manufacturer, model or SIN, K-factor, temperature rating, finish, quantity and last update date.<\/li>\n<li><strong>For concealed sprinklers:<\/strong> we suggest adding spare cover plates matching the model and plate temperature, since the plate is part of the listed assembly.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cfcbaa elementor-widget elementor-widget-text-editor\" data-id=\"1cfcbaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Wrenches for the TYCO and Victaulic sprinklers AZEIDK supplies<\/h2>\n<p>Each model is installed with the wrench named in its data sheet. An ordinary wrench can damage the frame or bulb. Examples from the sprinklers listed on AZEIDK&#8217;s site:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d503f23 elementor-widget elementor-widget-text-editor\" data-id=\"d503f23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Sprinkler<\/th><th>Wrench per data sheet<\/th><\/tr><\/thead>\n<tbody>\n<tr><td><a href=\"\/en\/sa\/products\/tyco-series-ty-b-upright-pendent-and-recessed-pendent-fire-sprinklers\/\">TYCO TY-B upright and pendent<\/a><\/td><td>W-Type 6 (TFP151)<\/td><\/tr>\n<tr><td>TYCO TY-B recessed pendent<\/td><td>W-Type 7 (TFP151)<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/tyco-ec-8c-recessed-pendent-corridor-sprinkler-ty4282\/\">TYCO EC-8C TY4282<\/a><\/td><td>W-Type 6 for pendent, W-Type 7 for recessed (TFP226)<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/tyco-series-rfii-royal-flush-ii-concealed-pendent-sprinklers-ty3531-and-ty3551\/\">TYCO Royal Flush II concealed<\/a><\/td><td>Dedicated RFII wrench only<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/tyco-series-ds-1-dry-type-fire-sprinklers-ty3155-ty3255-and-ty3355\/\">TYCO DS-1 dry type<\/a><\/td><td>As stated in the model&#8217;s data sheet<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/victaulic-firelock-fl-qr-sw-horizontal-sidewall-sprinklers-v2826-v4226-v2710-and-v3410\/\">Victaulic FireLock FL-QR-SW sidewall<\/a> and <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-qr-st-esfr-k16-8-pendent-storage-sprinkler-v4702\/\">Victaulic V4702 ESFR<\/a><\/td><td>As stated in Victaulic&#8217;s installation instructions for the model<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa25d92 elementor-widget elementor-widget-text-editor\" data-id=\"aa25d92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A practical tip: order the wrenches with the heads on the same purchase order, and fix a label inside the cabinet linking each wrench to the model it serves.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ddea58 elementor-widget elementor-widget-text-editor\" data-id=\"5ddea58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where should the cabinet go?<\/h2>\n<p>The NFPA article says the cabinet must be on the premises, in an area that stays within the sprinkler&#8217;s maximum ceiling temperature, which is 100\u00b0F (38\u00b0C) for ordinary sprinklers. Viking adds that the cabinet must not be exposed to corrosive atmospheres and should sit next to the main riser, easy to reach.<\/p>\n<p>On many Saudi sites, summer temperatures exceed that limit in roof rooms, unconditioned warehouses and outdoor pump rooms. We suggest an indoor, air-conditioned location near the valve room or riser, and making sure security and maintenance staff know where it is.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9940403 elementor-widget elementor-widget-text-editor\" data-id=\"9940403\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Who supplies the cabinet and who keeps it stocked?<\/h2>\n<p>On new projects the fire contractor usually supplies the cabinet and its contents as part of the sprinkler scope and hands them over with the final documents: as-built drawings, the data sheet for each sprinkler and the list of installed heads. After handover, responsibility moves to the owner or facility management, who restock the cabinet after every replacement and update the list whenever a fit-out or extension adds new sprinklers. Make the cabinet a fixed item on the <a href=\"\/en\/sa\/services\/documentation-final-handover\/\">documentation and final handover<\/a> checklist so a shortfall is not discovered after the first incident.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9c5ad0 elementor-widget elementor-widget-text-editor\" data-id=\"c9c5ad0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When is a spare sprinkler used?<\/h2>\n<p>The NFPA article lists conditions that call for replacement, several of which TFP226 also states:<\/p>\n<ul>\n<li>The sprinkler has operated in a fire.<\/li>\n<li>It leaks.<\/li>\n<li>Physical damage, such as bent or cracked frame arms.<\/li>\n<li>Wrong orientation, such as an upright installed as a pendent.<\/li>\n<li>Bulb fluid has leaked out.<\/li>\n<li>Paint not applied by the manufacturer.<\/li>\n<li>Loading that affects performance and cannot be removed with compressed air.<\/li>\n<\/ul>\n<p>The article notes that minor corrosion or faded bulb fluid alone does not require replacement. New heads are checked for leaks at working pressure, and if more than 20 sprinklers are replaced a full hydrostatic test to NFPA 13 is required; see our <a href=\"\/en\/sa\/media-center\/fire-fighting-hydrostatic-pressure-test\/\">hydrostatic pressure test article<\/a>. After any replacement, restock the cabinet straight away so it is complete for the next event.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b88e336 elementor-widget elementor-widget-text-editor\" data-id=\"b88e336\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common spare cabinet mistakes<\/h2>\n<ul>\n<li>Only upright spares in the cabinet while most installed heads are pendent or concealed.<\/li>\n<li>Spares with a different temperature rating from the heads in kitchens or plant rooms.<\/li>\n<li>No wrench for the concealed or recessed sprinklers.<\/li>\n<li>An old sprinkler list that misses fit-out changes or extensions.<\/li>\n<li>A cabinet in a hot roof room or next to chemicals.<\/li>\n<\/ul>\n<p>These points can be checked during <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance<\/a> visits, alongside the inspection requirements covered in our <a href=\"\/en\/sa\/media-center\/nfpa-25-itm-water-based-systems-guide\/\">NFPA 25 guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e00e6bd elementor-widget elementor-widget-text-editor\" data-id=\"e00e6bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>How many sprinklers go in a spare sprinkler head box?<\/h3><\/summary><p>At least 6 for fewer than 300 installed sprinklers, 12 for 300 to 1,000, and 24 for more than 1,000, covering every installed type and temperature rating.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is it enough for spares to be the same brand?<\/h3><\/summary><p>No. They must match the type and temperature rating, and ideally the model, K-factor, response and finish as well.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is a sprinkler wrench required in the cabinet?<\/h3><\/summary><p>Yes. NFPA 13 requires a sprinkler wrench in the cabinet, and each model has the wrench named in its data sheet.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What is the maximum temperature for the cabinet location?<\/h3><\/summary><p>100\u00b0F (38\u00b0C) for ordinary sprinklers, away from corrosive atmospheres.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is a pressure test needed after replacing a sprinkler?<\/h3><\/summary><p>New heads are checked for leaks at working pressure. If more than 20 sprinklers are replaced, a full hydrostatic test to NFPA 13 is required.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What if the installed sprinkler model is discontinued?<\/h3><\/summary><p>Do not stock a substitute with different characteristics without review. Ask the designer or supplier to propose a listed head with the properties the system needs, then update the list.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a66c95 elementor-widget elementor-widget-text-editor\" data-id=\"1a66c95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>A spare sprinkler cabinet is a small item, but a missing or incomplete one stretches system downtime after any incident. Size the stock from the total installed sprinklers, cover every type and temperature rating, include the right wrench and an up-to-date list, and keep the cabinet indoors at a moderate temperature. The TYCO and Victaulic sprinklers mentioned here are available through AZEIDK&#8217;s <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a> and <a href=\"\/en\/sa\/services\/technical-supply-of-fire-safety-systems\/\">technical supply<\/a> service.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e41abf elementor-widget elementor-widget-text-editor\" data-id=\"8e41abf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need a spare sprinkler cabinet that matches your system?<\/strong> Send the list of installed sprinklers and the AZEIDK team will help you set the models, quantities and wrenches. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5a303b elementor-widget elementor-widget-text-editor\" data-id=\"f5a303b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/facilityexecutive.com\/news-from-nfpa-spare-sprinklers-and-when-to-replace-in-your-facility\" rel=\"nofollow noopener\" target=\"_blank\">Facility Executive \/ NFPA Journal: Spare Sprinklers And When To Replace<\/a> \u00b7 <a href=\"https:\/\/www.vikinggroupinc.com\/media\/732\" rel=\"nofollow noopener\" target=\"_blank\">Viking: Sprinkler Wrenches and Cabinets, F_122598<\/a> \u00b7 <a href=\"https:\/\/my.ashe.org\/blogs\/chad-beebe\/2018\/02\/08\/nfpa-13-nfpa-25\" rel=\"nofollow noopener\" target=\"_blank\">ASHE: NFPA 13 \/ NFPA 25<\/a> \u00b7 TYCO TFP151 Series TY-B data sheet (May 2020, hosted on AZEIDK&#8217;s site) \u00b7 <a href=\"https:\/\/docs.johnsoncontrols.com\/tycofire\/api\/khub\/documents\/iJ_sLa0Zgebws3FVQPEvMA\/content\" rel=\"nofollow noopener\" target=\"_blank\">TYCO TFP226 (August 2022)<\/a> \u00b7 AZEIDK Royal Flush II product page<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Spare sprinkler head box guide: how many spares NFPA 13 requires (6 to 24), which wrench each TYCO and Victaulic model needs, and where to keep the cabinet.<\/p>\n","protected":false},"author":0,"featured_media":24949,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,320],"tags":[],"azeidk_region":[223],"class_list":["post-25197","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-codes-certifications-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=25197"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25197\/revisions"}],"predecessor-version":[{"id":25799,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25197\/revisions\/25799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24949"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=25197"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=25197"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=25197"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=25197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}