{"id":25119,"date":"2026-11-14T13:45:00","date_gmt":"2026-11-14T10:45:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-14T13:46:06","modified_gmt":"2026-11-14T10:46:06","slug":"fire-hose-reel-how-to-use","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-hose-reel-how-to-use\/","title":{"rendered":"How to Use a Fire Hose Reel Step by Step: Valve, Hose, Nozzle and When Not To"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"25119\" class=\"elementor elementor-25119 elementor-25118 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c8cf629 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"c8cf629\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-30dcad5 elementor-widget elementor-widget-text-editor\" data-id=\"30dcad5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">How to use a fire hose reel, in short: raise the alarm, open the valve, run the hose out toward the fire, then open the nozzle and aim the water at the base of the flames, not at the smoke. This is the sequence published by the Hong Kong Fire Services Department for hose reels, and it matches what manufacturers print on their cabinets. Never use a hose on a live electrical fire or on burning oil.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98bb183 elementor-widget elementor-widget-text-editor\" data-id=\"98bb183\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>The correct order for a manual hose reel: alarm, open the valve, run out the hose, then open the nozzle and aim at the base of the fire.<\/li>\n<li>An automatic hose reel turns the water on by itself when the hose is pulled out, as with the SFFECO automatic reel.<\/li>\n<li>A folded rack hose is different: lay it out fully first, then open the valve gradually, as the Falcon Gold 1.5 in hose catalogue states.<\/li>\n<li>Water must not be used on electrical fires, flammable liquids or deep fat fryer fires, according to OSHA guidance.<\/li>\n<li>The common hose reel length in fire hose cabinets is 30 m; actual reach depends on that length, the walking route and the water pressure.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47c71b6 elementor-widget elementor-widget-text-editor\" data-id=\"47c71b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What are the components of a fire hose reel cabinet?<\/h2>\n<p>Before the steps, know what you will be handling. The fire hose cabinet is part of the building&#8217;s <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>. The contents of the <a href=\"\/en\/sa\/products\/falcon-gold-single-door-mild-steel-fire-hose-reel-cabinet\/\">Falcon Gold single-door cabinet<\/a>, as shown in its catalogue:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Component<\/th><th>What it does in use<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Reel valve (angle valve)<\/td><td>Lets water from the network into the hose<\/td><\/tr>\n<tr><td>Reel and swinging arm<\/td><td>The reel turns to pay out the hose; the arm swings out toward the direction of pull<\/td><\/tr>\n<tr><td>Hose<\/td><td>25 mm diameter, 30 m long, 12 bar working pressure per the catalogue<\/td><\/tr>\n<tr><td>Adjustable nozzle<\/td><td>Three positions: jet, spray and shut-off<\/td><\/tr>\n<tr><td>Printed operating instructions<\/td><td>Label on the cabinet showing the steps<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The same catalogue shows LPCB approval to EN 671-1:2012, the standard for hose reels with semi-rigid hose. Types and sizes are covered in <a href=\"\/en\/sa\/media-center\/fire-hose-cabinet-types-sizes-components\/\">fire hose cabinet types, sizes and components<\/a>. Reel lengths, bores, installation and EN 671 inspection are in our <a href=\"\/en\/sa\/media-center\/fire-hose-reel-guide\/\">fire hose reel guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d96e1e elementor-widget elementor-widget-text-editor\" data-id=\"9d96e1e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to use a fire hose reel, step by step<\/h2>\n<p>These steps apply to the manual hose reel found in most building corridors in Saudi Arabia:<\/p>\n<ol>\n<li><strong>Raise the alarm first.<\/strong> Break the glass of the manual call point or press it, and warn people nearby. In some buildings this also starts the fire pump. Then call Civil Defense on 998, or ask someone else to call.<\/li>\n<li><strong>Assess the fire before you approach.<\/strong> If the fire is large, the smoke is thick or your escape route is threatened, leave and close the door behind you. A hose reel is for a fire in its early stage only.<\/li>\n<li><strong>Open the cabinet door and the valve.<\/strong> Turn the reel valve anticlockwise until fully open. The nozzle is still closed, so the hose fills with water but nothing comes out.<\/li>\n<li><strong>Run the hose out toward the fire.<\/strong> Hold the nozzle and walk toward the fire; the reel swings out and the hose pays out. Pull enough length and avoid sharp bends and wrapping it around door frames.<\/li>\n<li><strong>Take a safe position.<\/strong> Stand at a reasonable distance with your back toward the exit, and stay low beneath the smoke layer.<\/li>\n<li><strong>Open the nozzle and aim at the base of the flames.<\/strong> Start on jet for reach, then sweep the nozzle side to side across the base of the burning material. Spray covers a wider area at closer range.<\/li>\n<li><strong>After the fire is out.<\/strong> Close the nozzle, then the valve. Do not rewind a wet hose without telling the maintenance team, and record the use in the fire safety log.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1297fc0 elementor-widget elementor-widget-text-editor\" data-id=\"1297fc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Do I open the valve before pulling out the hose?<\/h2>\n<p>It depends on what is in the cabinet:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Equipment<\/th><th>Order<\/th><th>Why<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Manual reel with semi-rigid hose (25 mm)<\/td><td>Open the valve, then run out the hose<\/td><td>The hose keeps its round shape and pays out from the reel already full, with the nozzle closed until you reach the fire<\/td><\/tr>\n<tr><td>Automatic reel<\/td><td>Just pull the hose<\/td><td>The <a href=\"\/en\/sa\/products\/sffeco-automatic-type-hose-reel\/\">SFFECO automatic hose reel<\/a> page states water opens automatically on pull-out<\/td><\/tr>\n<tr><td>Folded rack and reel hose, 1.5 in<\/td><td>Lay the hose out fully, then open the valve gradually<\/td><td>A flat hose can kink if it fills while still folded; the <a href=\"\/en\/sa\/products\/1-5-inch-rack-and-reel-fire-hose\/\">Falcon Gold 1.5 in hose<\/a> catalogue says to deploy it as fully as practical and open the valve gradually<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The 1.5 in hose catalogue also states the nozzle should be operated by trained personnel. The 25 mm reel is intended for first response by building occupants.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b21205 elementor-widget elementor-widget-text-editor\" data-id=\"7b21205\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When should you not use a fire hose?<\/h2>\n<p>OSHA&#8217;s guidance on fire classes is clear on these cases:<\/p>\n<ul>\n<li><strong>Live electrical fires:<\/strong> do not use water. It conducts electricity and may cause electrocution. Isolate power if possible and use a suitable CO2 or dry powder extinguisher. The HKUST hose reel operating poster also states the reel is not suitable for electrical fires.<\/li>\n<li><strong>Flammable liquids (petrol, diesel, solvents, paints):<\/strong> water is ineffective and can spread the burning liquid.<\/li>\n<li><strong>Deep fat fryers in commercial kitchens:<\/strong> do not use water on a fryer fire; use a wet chemical extinguisher and the kitchen suppression system.<\/li>\n<li><strong>A large fire or thick smoke:<\/strong> any fire past its first stage is a job for Civil Defense. Evacuate first.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e99a7d elementor-widget elementor-widget-text-editor\" data-id=\"7e99a7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How far does a fire hose reach?<\/h2>\n<p>Reach has two parts: hose length and the throw of the water from the nozzle. The Falcon Gold reels and the SFFECO automatic reel shown on AZEIDK&#8217;s site carry 30 m of hose, and the 1.5 in rack hose comes in 50, 75 and 100 ft lengths (about 15.2, 22.9 and 30.5 m). Throw depends on water pressure, nozzle type and setting, so there is no single figure for every building.<\/p>\n<p>In practice, length is measured along the actual walking route around walls and doors, not as a straight line on the drawing. That is why the designer places cabinets so every point on the floor is covered under the approved design; see the <a href=\"\/en\/sa\/media-center\/nfpa-14-standpipe-hose-systems\/\">NFPA 14 standpipe and hose systems guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fae371 elementor-widget elementor-widget-text-editor\" data-id=\"4fae371\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is the difference between a hose reel, a Civil Defense outlet and an extinguisher?<\/h2>\n<p>The same corridor may hold three different pieces of equipment, each for a different user. Mixing them up wastes time when it matters:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Equipment<\/th><th>Who uses it<\/th><th>When<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Hose reel (25 mm) or 40 mm (1.5 in) hose station<\/td><td>Building occupants and the emergency team<\/td><td>An ordinary combustibles fire in its early stage<\/td><\/tr>\n<tr><td>65 mm (2.5 in) outlet in the cabinet or stair<\/td><td>Civil Defense crews with their own hoses<\/td><td>A fire past its first stage<\/td><\/tr>\n<tr><td>Portable extinguisher in or beside the cabinet<\/td><td>Anyone nearby<\/td><td>A very small fire, or an electrical or liquid fire, depending on extinguisher type<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>System classes (Class I, II and III) and outlet sizes are explained in <a href=\"\/en\/sa\/media-center\/fire-hose-cabinet-types-sizes-components\/\">fire hose cabinet types<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d9f71f elementor-widget elementor-widget-text-editor\" data-id=\"9d9f71f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>A quick check of the cabinet before you need it<\/h2>\n<p>A hose that fails during a fire is usually discovered too late. A visual check takes a minute per cabinet and follows the inspection points in the Falcon Gold hose catalogue:<\/p>\n<ul>\n<li>The cabinet is visible, not padlocked, and nothing blocks the door.<\/li>\n<li>The hose jacket is free of cuts, wear and abrasion.<\/li>\n<li>Couplings are sound and secure, with no leakage at the valve.<\/li>\n<li>The nozzle is in place and moves between its three positions.<\/li>\n<li>The hose is dry and evenly rolled after any use or test.<\/li>\n<\/ul>\n<p>Any finding is recorded and passed to the maintenance team; full periodic inspection and testing remains the job of the appointed maintenance contractor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84b32d1 elementor-widget elementor-widget-text-editor\" data-id=\"84b32d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes when using a fire hose<\/h2>\n<ul>\n<li>Aiming at the smoke or the top of the flames instead of the base, which wastes water while the fire keeps burning.<\/li>\n<li>Pulling the hose around a sharp corner so it kinks and flow drops.<\/li>\n<li>Standing with the fire between you and the exit.<\/li>\n<li>Fighting the fire before raising the alarm, which delays everyone else&#8217;s evacuation.<\/li>\n<li>A cabinet padlocked or blocked by stock, so time is lost when it matters. Periodic inspection catches this.<\/li>\n<\/ul>\n<p>Periodic inspection of the valve, hose and nozzle, with records, is part of <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive maintenance contracts<\/a> and helps you prepare for Civil Defense inspection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2614459 elementor-widget elementor-widget-text-editor\" data-id=\"2614459\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>How do I operate a fire hose reel?<\/h3><\/summary><p>Raise the alarm, open the reel valve, run the hose out toward the fire, then open the nozzle and aim at the base of the flames.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Do I open the valve before pulling out the hose?<\/h3><\/summary><p>Yes, on a manual semi-rigid hose reel. With a folded rack hose, lay it out first and then open the valve gradually; on an automatic reel the water turns on as you pull.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Can I use a fire hose on an electrical fire?<\/h3><\/summary><p>No. Water conducts electricity and may cause electrocution. Isolate power if possible and use an extinguisher suitable for electrical fires.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How far does a fire hose reach?<\/h3><\/summary><p>A typical hose reel holds 30 m of hose, plus the throw of the water, which depends on pressure and nozzle. Reach is measured along the actual walking route.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What are the components of a fire hose reel?<\/h3><\/summary><p>The valve, the reel with its swinging arm, the hose, the adjustable nozzle and fittings, all inside the cabinet with operating instructions.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Who is supposed to use a fire hose cabinet?<\/h3><\/summary><p>The 25 mm hose reel is for first response by building occupants. The 2.5 in outlet is for Civil Defense crews.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bf07ab elementor-widget elementor-widget-text-editor\" data-id=\"0bf07ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Using a fire hose takes a minute of prior knowledge: alarm, valve, run out, nozzle, base of the flames. Know which type of hose is in your cabinet, never use it on electricity or burning oil, and leave if the fire grows. A cabinet that is inspected and kept clear is half the preparation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cca307 elementor-widget elementor-widget-text-editor\" data-id=\"1cca307\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need fire hose cabinets supplied or inspected in your building?<\/strong> AZEIDK supplies, installs and maintains fire hose cabinets and reels as part of its <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a> across Saudi Arabia. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0bb587 elementor-widget elementor-widget-text-editor\" data-id=\"a0bb587\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/hkfsd.gov.hk\/sc\/cep_edu\/cep\/cep_3skill_index\/cep_3skill_fire\/Proper_Operation_Fire_Hose_Reel.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Hong Kong Fire Services Department: Proper Operation of Fire Hose Reel<\/a> \u00b7 <a href=\"https:\/\/hseo.hkust.edu.hk\/sites\/default\/files\/Proper%20Operation%20of%20the%20Fire%20Hose%20Reel.pdf\" rel=\"nofollow noopener\" target=\"_blank\">HKUST Health, Safety and Environment Office: Proper Operation of the Fire Hose Reel<\/a> \u00b7 <a href=\"https:\/\/www.osha.gov\/etools\/evacuation-plans-procedures\/emergency-standards\/portable-extinguishers\/about\" rel=\"nofollow noopener\" target=\"_blank\">OSHA eTool: Portable Fire Extinguishers, Extinguisher Basics (fire classes)<\/a> \u00b7 <a href=\"\/en\/sa\/products\/falcon-gold-single-door-mild-steel-fire-hose-reel-cabinet\/\">AZEIDK product page: Falcon Gold single-door fire hose reel cabinet (FG-1001R \/ FGR-1001R)<\/a> \u00b7 <a href=\"\/en\/sa\/products\/sffeco-automatic-type-hose-reel\/\">AZEIDK product page: SFFECO automatic type hose reel<\/a> \u00b7 <a href=\"\/en\/sa\/products\/1-5-inch-rack-and-reel-fire-hose\/\">AZEIDK product page: 1.5 in rack and reel fire hose<\/a><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>How to use a fire hose reel step by step: raise the alarm, open the valve, run out the hose, aim at the base of the fire, and when water must not be used.<\/p>\n","protected":false},"author":0,"featured_media":24910,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-25119","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=25119"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25119\/revisions"}],"predecessor-version":[{"id":25721,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25119\/revisions\/25721"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24910"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=25119"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=25119"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=25119"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=25119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}