{"id":25085,"date":"2026-11-14T11:37:30","date_gmt":"2026-11-14T08:37:30","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-14T11:38:26","modified_gmt":"2026-11-14T08:38:26","slug":"civil-defense-requirements-offices-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/civil-defense-requirements-offices-saudi\/","title":{"rendered":"Civil Defense Requirements for Offices in Saudi Arabia: Extinguishers, Alarms, Exits and Salamah"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"25085\" class=\"elementor elementor-25085 elementor-25084 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ae8bae9 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"ae8bae9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e82f4d2 elementor-widget elementor-widget-text-editor\" data-id=\"e82f4d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">Civil Defense requirements for offices in Saudi Arabia come down to four things an inspector checks first: portable fire extinguishers suited to the hazard and spaced correctly, fire alarm coverage where the building classification calls for it or the office sits inside a building that already has a system, emergency exits that are unlocked and marked with exit signs and emergency lighting, and a Salamah safety license issued through the Civil Defense platform according to your activity category. A small office does not need what a workshop or restaurant needs, but it is not exempt from the basics. For the building-level engineering view (classification, sprinklers, egress), see our guide to <a href=\"\/en\/sa\/media-center\/office-buildings-fire-safety\/\">fire safety in office buildings<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b889e71 elementor-widget elementor-widget-text-editor\" data-id=\"b889e71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>Civil Defense safety licenses are issued through the Salamah platform (salamah.998.gov.sa). Activities are either direct (low to medium risk) or indirect (high risk).<\/li>\n<li>For direct activities, you enter the details of a safety equipment invoice from a qualified safety company, or a technical report from an approved engineering office, depending on the activity.<\/li>\n<li>Offices are usually treated as light hazard when laying out extinguishers under NFPA 10: a minimum 2-A rating and a maximum travel distance of 22.9 m (75 ft).<\/li>\n<li>Whether a fire alarm system is required depends on the Saudi Building Code criteria for the building&#8217;s occupancy, occupant load and number of storeys. An office inside an equipped tower must stay covered by the building system after any fit-out change.<\/li>\n<li>The license is valid for one full year from final approval, and renewal can be requested one month before expiry.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06e5a4b elementor-widget elementor-widget-text-editor\" data-id=\"06e5a4b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What are the Civil Defense requirements for offices?<\/h2>\n<p>An administrative office usually carries a low fire load: paper, furniture, computers and power wiring. Office safety requirements therefore focus on early detection, first-aid firefighting and safe evacuation rather than special suppression systems. In practice, the inspector, or the engineering office preparing the technical report, will look for:<\/p>\n<ul>\n<li>Fire extinguishers of the right number and type, mounted where they are visible, with a current inspection tag.<\/li>\n<li>Smoke or heat detectors connected to the building fire alarm system where one exists, or as the approved design requires.<\/li>\n<li>Emergency exits free of chains or padlocks, illuminated exit signs, and emergency lighting in corridors.<\/li>\n<li>A closed electrical panel and safe wiring, with no temporary runs or daisy-chained power strips.<\/li>\n<li>A first-aid box and safety signage.<\/li>\n<li>An inspection and maintenance log proving that extinguishers, the alarm system and emergency lighting are checked regularly.<\/li>\n<\/ul>\n<p>This list is practical guidance, not an official text. What governs your case is the requirement shown for your activity on the Salamah platform and what the Saudi Fire Code SBC 801 requires for the occupancy of the building your office is in.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9355a0 elementor-widget elementor-widget-text-editor\" data-id=\"c9355a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How is a Salamah license issued for an office?<\/h2>\n<p>Salamah is the General Directorate of Civil Defense&#8217;s online platform for facility safety licensing. According to the overview published by Elm, the company that developed the platform, activities fall into two groups:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Item<\/th><th>Direct activities<\/th><th>Indirect activities<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Risk level<\/td><td>Low to medium<\/td><td>High<\/td><\/tr>\n<tr><td>What you submit<\/td><td>Safety equipment invoice from a qualified safety company, or a technical report from an approved engineering office, depending on the activity<\/td><td>Contract with an approved safety company plus maintenance contracts<\/td><\/tr>\n<tr><td>Inspection<\/td><td>Depends on the activity; some low-risk activities are licensed instantly<\/td><td>Civil Defense inspection before issue<\/td><\/tr>\n<tr><td>License validity<\/td><td colspan=\"2\">One full year from final approval; renewal can be requested one month before expiry<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>To find your category, use the investor journey service on the platform, which shows the classification and requirements for each activity. Make sure the application data matches your commercial registration, municipal license and lease, because mismatches are one of the most common causes of delay. Registration and renewal are covered step by step in our <a href=\"\/en\/sa\/media-center\/salamah-certificate-civil-defense-guide\/\">Salamah certificate guide<\/a>.<\/p>\n<p>If your activity needs a technical report, it is issued by an approved engineering office registered on Salamah. Through its <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support service<\/a>, AZEIDK inspects the office, confirms that extinguishers, alarm coverage and exits are ready, installs the systems, issues the safety equipment installation certificate and coordinates with the engineering office.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bdb10d3 elementor-widget elementor-widget-text-editor\" data-id=\"bdb10d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How many fire extinguishers does an office need? Office safety requirements for extinguishers<\/h2>\n<p>The number depends on floor area and hazard level. NFPA 10 classifies spaces as light, ordinary or extra hazard, and ordinary offices usually fall under light hazard. The key values for Class A extinguishers (paper, wood, fabric fires) are:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Item<\/th><th>Light hazard (typical offices)<\/th><th>Ordinary hazard (large archive or storage inside the office)<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Minimum rating per extinguisher<\/td><td>2-A<\/td><td>2-A<\/td><\/tr>\n<tr><td>Area covered by one 2-A unit<\/td><td>6,000 ft\u00b2 (about 557 m\u00b2)<\/td><td>3,000 ft\u00b2 (about 279 m\u00b2)<\/td><\/tr>\n<tr><td>Maximum area per extinguisher<\/td><td>11,250 ft\u00b2 (about 1,045 m\u00b2)<\/td><td>11,250 ft\u00b2 (about 1,045 m\u00b2)<\/td><\/tr>\n<tr><td>Maximum travel distance to the nearest extinguisher<\/td><td>75 ft (22.9 m)<\/td><td>75 ft (22.9 m)<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The rule people miss: area is not the only check. A 150 m\u00b2 office is covered by a single 2-A extinguisher on area alone, but if the layout is long and narrow and the walk from the farthest point exceeds 22.9 m, you need a second unit. The count is calculated floor by floor.<\/p>\n<p>Type matters as much as quantity. A multipurpose ABC dry powder extinguisher covers paper and electrical fires, while a CO2 extinguisher suits server rooms and electrical panels because it leaves no residue on equipment. Compare the options in our <a href=\"\/en\/sa\/media-center\/falcon-gold-fire-extinguishers-types\/\">Falcon Gold extinguisher types guide<\/a>, and get a quick count with the <a href=\"\/en\/sa\/tools\/fire-extinguisher-calculator\/\">fire extinguisher calculator<\/a>.<\/p>\n<p>Under NFPA 10, an extinguisher with a gross weight up to 18.14 kg (40 lb) is mounted so its top is no higher than 1.5 m (5 ft) above the floor, with at least 102 mm (4 in) clearance underneath. It is inspected monthly at intervals not exceeding 31 days and maintained annually. See our <a href=\"\/en\/sa\/media-center\/fire-extinguisher-maintenance-refill\/\">extinguisher maintenance and refill guide<\/a> for details.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7190320 elementor-widget elementor-widget-text-editor\" data-id=\"7190320\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Does a small office need a fire alarm system?<\/h2>\n<p>The answer depends on the building before the office. The Saudi Fire Code SBC 801 sets when a fire alarm system is required based on the building&#8217;s occupancy classification, occupant load and number of storeys, and the designer applies those criteria to your case. In practice you will face one of three situations:<\/p>\n<ul>\n<li><strong>Office inside a tower or commercial complex with a fire alarm system:<\/strong> the office is part of the building system. A new gypsum partition, a false ceiling or an enclosed meeting room can create a space with no detector, so detectors must be added or relocated, connected to the building panel and the panel programming updated. Detectors must never be disconnected or covered during finishing works and then forgotten.<\/li>\n<li><strong>Office in a small building with no fire alarm system:<\/strong> the requirement comes from the activity requirements on Salamah and from what the engineering office states in the technical report. Do not buy devices before you know what is actually required.<\/li>\n<li><strong>Company headquarters occupying a whole building:<\/strong> the fire alarm system is designed for the entire building, usually as an addressable system that identifies the exact device location.<\/li>\n<\/ul>\n<p>In offices, smoke detectors normally go in corridors, offices and archive rooms, and heat detectors in the pantry to reduce false alarms from steam and cooking. Our article on <a href=\"\/en\/sa\/media-center\/fire-alarm-false-alarms-causes\/\">fire alarm false alarm causes<\/a> covers prevention, and the <a href=\"\/en\/sa\/media-center\/fire-alarm-installation-saudi\/\">fire alarm installation guide<\/a> covers the installation stages.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e294ed5 elementor-widget elementor-widget-text-editor\" data-id=\"e294ed5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Emergency exits and emergency lighting in offices<\/h2>\n<p>Most inspection findings in offices are not about equipment but about daily habits: an emergency door with an extra lock against theft, a corridor turned into a carton store, or an exit sign that is off. The operating procedures for life safety systems in offices, issued by the Expenditure Efficiency and Government Projects Authority (2020), state that securing fire exits with chains or locked cables is prohibited, and that exits fitted with magnetic locks are tested for release and the test is recorded.<\/p>\n<p>The same document, referencing BS 5266, calls for a 10-minute functional test of emergency lighting every month and a full 3-hour test every year. These procedures were written for government offices, but they are a sound practical reference for any office. For selecting emergency lights and exit signs, see our <a href=\"\/en\/sa\/media-center\/emergency-lighting-exit-signs-saudi\/\">emergency lighting and exit signs guide<\/a>.<\/p>\n<p>The number of exits, their width and travel distances are set by the building codes according to occupant load and building classification. If your office is inside a tower, exits and stairs are the building&#8217;s responsibility; yours is to make sure your interior layout never blocks access to them.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e52c630 elementor-widget elementor-widget-text-editor\" data-id=\"e52c630\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Does an office inside a tower need its own license?<\/h2>\n<p>The Salamah license is tied to the establishment and its activity as shown in the commercial registration and municipal license, so each establishment applies for its own activity even when the building itself is licensed. Shared building systems such as the central fire alarm, sprinklers, fire pumps and stairs remain the responsibility of the building owner or management, and you will usually be asked to show that your office is covered by them and that your fit-out has not impaired them. In February 2024, the Saudi Business Center announced that the municipal commercial license and the safety license can be issued instantly in one step for more than 600 activities, subject to conditions that include a lease and a safety equipment invoice or technical report.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aec886c elementor-widget elementor-widget-text-editor\" data-id=\"aec886c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Pre-inspection checklist<\/h2>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Item<\/th><th>What to check<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Extinguishers<\/td><td>Count by area and travel distance, correct type near electrical equipment and servers, monthly inspection tag<\/td><\/tr>\n<tr><td>Fire alarm<\/td><td>No enclosed room without a detector, detectors clean and uncovered, no faults on the panel<\/td><\/tr>\n<tr><td>Exits<\/td><td>Unlocked, clear corridors, exit signs lit<\/td><\/tr>\n<tr><td>Emergency lighting<\/td><td>Works on power failure, monthly test log available<\/td><\/tr>\n<tr><td>Electrical<\/td><td>Panel closed, no temporary wiring, no overloaded power strips<\/td><\/tr>\n<tr><td>Documents<\/td><td>Commercial registration, municipal license, lease, invoice or technical report<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>You can also run a self-check with the interactive <a href=\"\/en\/sa\/tools\/salamah-inspection-checklist\/\">Salamah inspection checklist<\/a> before you book the inspection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6be1937 elementor-widget elementor-widget-text-editor\" data-id=\"6be1937\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>What are the Civil Defense requirements for small offices?<\/h3><\/summary><p>Suitable, correctly spaced extinguishers; unlocked exits with exit signs and emergency lighting; fire alarm coverage where the building has a system or the design requires one; and a license through Salamah according to the activity category.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How many fire extinguishers does an office need?<\/h3><\/summary><p>In a typical light hazard office, one 2-A extinguisher covers up to about 557 m\u00b2, provided the travel distance to the nearest unit does not exceed 22.9 m. Count each floor separately and add a CO2 unit near servers and electrical panels where needed.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Does a small office need a fire alarm system?<\/h3><\/summary><p>It depends on the building&#8217;s occupancy, occupant load and number of storeys under SBC 801. If the building has a fire alarm system, the office must remain covered by it after any interior change.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Does an office inside a tower need its own license?<\/h3><\/summary><p>Yes. The Salamah license is tied to the establishment and its activity, so each establishment applies separately. Shared building systems remain the responsibility of the owner or building management.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How long is a Salamah license valid?<\/h3><\/summary><p>One full year from final approval. Renewal can be requested one month before expiry.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Are Civil Defense requirements for shops different from offices?<\/h3><\/summary><p>The principles are the same, but a shop may hold larger quantities of combustible goods, which raises the hazard level and the number of extinguishers. The activity category on Salamah decides what each one needs.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Who issues the technical report for an office?<\/h3><\/summary><p>An approved engineering or technical office registered on the Salamah platform, after inspecting the premises. AZEIDK handles this report through an approved engineering office, installs the systems and issues the safety equipment installation certificate as part of its Civil Defense approval support service.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1dd00e6 elementor-widget elementor-widget-text-editor\" data-id=\"1dd00e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Civil Defense requirements for offices are not complicated, but applications are often held up by small details: an extinguisher too far from the last room, a detector covered during fit-out, or a locked emergency door. Start by confirming your activity category on Salamah, prepare extinguishers, alarm coverage and exits on that basis, and keep the periodic inspection log, because it is what proves your readiness at renewal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-898d98a elementor-widget elementor-widget-text-editor\" data-id=\"898d98a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Fitting out a new office or renewing your Salamah license?<\/strong> The AZEIDK team inspects the office, specifies the extinguishers and fire alarm changes required, installs the systems, issues the safety equipment installation certificate and coordinates with an approved engineering office for the technical report through our <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support service<\/a>. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3409aa elementor-widget elementor-widget-text-editor\" data-id=\"c3409aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/salamah.998.gov.sa\/\" rel=\"nofollow noopener\" target=\"_blank\">Salamah platform, General Directorate of Civil Defense (in Arabic)<\/a> \u00b7 <a href=\"https:\/\/elm.sa\/ar\/our-business\/digital-products\/Documents\/En\/Salamah%20EN.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Salamah platform overview, Elm<\/a> \u00b7 <a href=\"https:\/\/expro.gov.sa\/api\/uploads\/\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629 \u0644\u0623\u0646\u0638\u0645\u0629 \u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u062d\u064a\u0627\u0629 \u0641\u064a \u0627\u0644\u0645\u0643\u0627\u062a\u0628.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Operating procedures for life safety systems in offices, Expenditure Efficiency and Government Projects Authority, EOM-ZO0-PR-000048-AR, 2020 (in Arabic)<\/a> \u00b7 <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/10\/10_A2025_PFE_AAA_FD_FRStatements.pdf\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 10 First Draft Report, Annual 2025 cycle, NFPA<\/a> \u00b7 <a href=\"https:\/\/www.alkhafji.news\/2024\/02\/13\/592861.html\" rel=\"nofollow noopener\" target=\"_blank\">Al-Khafji News: Saudi Business Center enables instant municipal commercial and safety licenses for 600+ activities, 13 February 2024 (in Arabic)<\/a><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Civil Defense requirements for offices in Saudi Arabia: extinguisher count under NFPA 10, when a fire alarm is needed, exits, emergency lighting and Salamah.<\/p>\n","protected":false},"author":0,"featured_media":24893,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-25085","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25085","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=25085"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25085\/revisions"}],"predecessor-version":[{"id":25687,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/25085\/revisions\/25687"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24893"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=25085"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=25085"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=25085"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=25085"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}