{"id":24706,"date":"2026-11-12T21:51:34","date_gmt":"2026-11-12T18:51:34","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-12T21:52:36","modified_gmt":"2026-11-12T18:52:36","slug":"fire-classes-triangle","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-classes-triangle\/","title":{"rendered":"Fire Triangle and Fire Extinguisher Classes A, B, C, D and K: Which Extinguisher for Which Fire"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"24706\" class=\"elementor elementor-24706 elementor-24705 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d64774 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"4d64774\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb0c7d4 elementor-widget elementor-widget-text-editor\" data-id=\"eb0c7d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">The <strong>fire triangle<\/strong> explains why a fire starts and why it goes out: fuel, heat and oxygen, with a fourth element added by engineers, the chemical chain reaction. Every extinguisher works by removing one or more of these elements. Because the fuel can be paper and wood, petrol, live electrical equipment, metal or cooking oil, fires are grouped into Classes A, B, C, D and K, and each class has extinguishers that suit it and others that make things worse.<\/p>\n<p>This guide links the fire triangle to fire extinguisher classes and agents, explains extinguisher labels under US and international rating, and what suits each area of a building as part of its <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c528098 elementor-widget elementor-widget-text-editor\" data-id=\"c528098\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>A fire needs fuel, heat, oxygen and a chain reaction at the same time. Remove any one and it stops.<\/li><li>Water cools, CO2 displaces oxygen, dry powder breaks the chain reaction, and foam seals a liquid surface from the air.<\/li><li>Under NFPA 10: Class A is ordinary solids, B is flammable liquids and gases, C is energized electrical equipment, D is combustible metals and K is cooking oils and fats.<\/li><li>Under ISO 3941, C means flammable gases, Class F matches US Class K, and there is no separate electrical class.<\/li><li>No single extinguisher covers every fire. ABC powder covers the first three classes only; metal and kitchen fires need dedicated units.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3f3902 elementor-widget elementor-widget-text-editor\" data-id=\"d3f3902\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is the fire triangle, and why did it become a tetrahedron?<\/h2>\n<p>Fire is a fast chemical reaction between a combustible material and oxygen that releases heat, light, flame and smoke. The fire triangle shows the three things needed to start it:<\/p>\n<ul><li><strong>Fuel:<\/strong> any material that burns, solid, liquid or gas.<\/li><li><strong>Heat:<\/strong> the energy that brings the fuel to ignition and keeps it burning.<\/li><li><strong>Oxygen:<\/strong> usually from the surrounding air.<\/li><\/ul>\n<p>A fourth element, the self-sustaining chain reaction in the flame, turns it into the fire tetrahedron; OSHA lists all four as conditions for a fire to continue. This matters because dry chemical powder, for example, does little cooling yet stops the reaction itself.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7d8116 elementor-widget elementor-widget-text-editor\" data-id=\"d7d8116\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How does each extinguisher put out a fire? The fire triangle and the agent<\/h2>\n<p>Each method targets one side of the tetrahedron:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Element removed<\/th><th>Method<\/th><th>Example agents<\/th><\/tr><\/thead><tbody><tr><td>Heat<\/td><td>Cooling the fuel below its ignition temperature<\/td><td>Water, the water in a foam solution, wet chemical in kitchens<\/td><\/tr><tr><td>Oxygen<\/td><td>Smothering: displacing oxygen or sealing the surface<\/td><td>Carbon dioxide (CO2), a foam blanket on a liquid, the crust formed by Class D powders<\/td><\/tr><tr><td>Chain reaction<\/td><td>Interrupting the chemical reaction in the flame<\/td><td>Dry chemical powder (ABC or BC)<\/td><\/tr><tr><td>Fuel<\/td><td>Removing the fuel or stopping its flow<\/td><td>Closing a gas or fuel valve, isolating the supply; usually not an extinguisher&#8217;s job<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Water cools very well, but on a burning liquid it can spread the fire, and on energized equipment it puts the user at risk of electric shock. CO2 knocks down flame quickly but disperses and does not cool wood or paper deeply, so OSHA does not recommend it for Class A fires because they may rekindle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3baba0e elementor-widget elementor-widget-text-editor\" data-id=\"3baba0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire classes under NFPA 10: A, B, C, D and K<\/h2>\n<p>NFPA 10, Standard for Portable Fire Extinguishers, classifies fires by what is burning:<\/p>\n<h3>Class A: ordinary combustibles<\/h3>\n<p>Wood, cloth, paper, rubber and many plastics. These leave embers, so they need cooling or a coating that stops re-ignition.<\/p>\n<h3>Class B: flammable liquids and gases<\/h3>\n<p>Petrol, diesel, oils, greases, oil-based paints, solvents, alcohols and flammable gases. The aim is to smother or break the reaction without scattering the burning material.<\/p>\n<h3>Class C: energized electrical equipment<\/h3>\n<p>Live panels, cables, motors and electronics. The agent must be non-conductive. Once the power is off, the fire is treated by the material that is burning, so burning cable insulation becomes a Class A fire.<\/p>\n<h3>Class D: combustible metals<\/h3>\n<p>Magnesium, titanium, zirconium, sodium, lithium and potassium, usually as shavings, flakes or powder in workshops and plants. Water and foam can react violently with burning metal, and some ordinary dry chemicals can also cause a dangerous reaction.<\/p>\n<h3>Class K: cooking oils and fats<\/h3>\n<p>Vegetable or animal oils and fats in commercial cooking appliances such as deep fat fryers. Water on them causes an eruption of steam and burning oil.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6574c5 elementor-widget elementor-widget-text-editor\" data-id=\"d6574c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which extinguisher for which class? Selection table<\/h2>\n<p>Based on OSHA guidance and manufacturer data; the label and datasheet of the actual model decide:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Extinguisher type<\/th><th>A<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>K<\/th><\/tr><\/thead><tbody><tr><td>Water<\/td><td>Yes<\/td><td>No<\/td><td>No<\/td><td>No<\/td><td>No<\/td><\/tr><tr><td>ABC dry powder<\/td><td>Yes<\/td><td>Yes<\/td><td>Yes<\/td><td>No<\/td><td>No<\/td><\/tr><tr><td>BC dry powder<\/td><td>No<\/td><td>Yes<\/td><td>Yes<\/td><td>No<\/td><td>No<\/td><\/tr><tr><td>Carbon dioxide (CO2)<\/td><td>Not recommended<\/td><td>Yes<\/td><td>Yes<\/td><td>No<\/td><td>No<\/td><\/tr><tr><td>AFFF foam<\/td><td>Yes<\/td><td>Yes<\/td><td>No<\/td><td>No<\/td><td>No<\/td><\/tr><tr><td>Wet chemical<\/td><td>Per datasheet<\/td><td>Per datasheet<\/td><td>No<\/td><td>No<\/td><td>Yes<\/td><\/tr><tr><td>Class D powder<\/td><td>No<\/td><td>No<\/td><td>No<\/td><td>Yes, for the metal on the label<\/td><td>No<\/td><\/tr><\/tbody><\/table><\/div>\n<p>ABC powder is the most common choice, but it leaves a heavy residue on sensitive equipment. The ABC vs BC difference is covered in our <a href=\"\/en\/sa\/media-center\/powder-fire-extinguisher-guide\/\">dry powder fire extinguisher guide<\/a>. Foam suits fuel and oil stores and car parks; sizes are in our <a href=\"\/en\/sa\/media-center\/foam-fire-extinguisher-afff-falcon-gold\/\">AFFF foam fire extinguisher guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9a0788 elementor-widget elementor-widget-text-editor\" data-id=\"c9a0788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Class B and Class C fire extinguishers: how to read the label<\/h2>\n<p>A US-rated extinguisher shows a number and a letter per class, for example 2A:10B:C. The number before A measures performance on ordinary fires; per OSHA each unit equals 1.25 gallons of water. The number before B relates to the area in square feet of a liquid fire a non-expert should be able to put out. The C carries no number: it only means the agent does not conduct electricity.<\/p>\n<h3>Why might a kitchen extinguisher show F?<\/h3>\n<p>Many extinguishers in Saudi Arabia are built to international standards, and ISO 3941 classifies fires by fuel only:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Fire type<\/th><th>US (NFPA 10)<\/th><th>International (ISO 3941)<\/th><\/tr><\/thead><tbody><tr><td>Ordinary solids<\/td><td>A<\/td><td>A<\/td><\/tr><tr><td>Flammable liquids<\/td><td>B<\/td><td>B<\/td><\/tr><tr><td>Flammable gases<\/td><td>Within B<\/td><td>C<\/td><\/tr><tr><td>Energized electrical equipment<\/td><td>C<\/td><td>No separate class<\/td><\/tr><tr><td>Metals<\/td><td>D<\/td><td>D<\/td><\/tr><tr><td>Cooking oils and fats<\/td><td>K<\/td><td>F<\/td><\/tr><tr><td>Lithium-ion batteries<\/td><td>No separate class<\/td><td>L (added in 2026)<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The third edition of ISO 3941 was published in January 2026, revising the 2007 edition, and added Class L for lithium-ion cells and batteries.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-753a5a0 elementor-widget elementor-widget-text-editor\" data-id=\"753a5a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Metal and kitchen fires: when a standard extinguisher is not enough<\/h2>\n<h3>Class D<\/h3>\n<p>Metal fire extinguishers use special powders. One manufacturer states that sodium chloride powder forms a crust that excludes air and dissipates heat, that copper powder was developed for lithium and lithium alloy fires, and that graphite is applied with a spark-proof scoop. The same manufacturer warns that Class D agents should not be used on lithium-ion battery fires because they conduct electricity. Class D extinguishers are not among the Falcon Gold extinguishers listed on the AZEIDK site; they are assessed with the designer based on the metal and quantity.<\/p>\n<h3>Class K<\/h3>\n<p>OSHA states that water and CO2 must not be used on deep fat fryer fires because of a possible explosive reaction, that a Class K extinguisher is used after the installed hood suppression system has operated, and that many Class K agents conduct electricity, so the appliance power is isolated first. Wet chemical reacts with hot oil to form a soapy layer that holds in the vapours. Selection and placement in a restaurant are covered in our <a href=\"\/en\/sa\/media-center\/wet-chemical-kitchen-fire-extinguisher-class-k\/\">Class K kitchen fire extinguisher guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68839c5 elementor-widget elementor-widget-text-editor\" data-id=\"68839c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to choose an extinguisher for each area<\/h2>\n<p>Ask what fuel is likely here, then pick an agent that removes a side of the fire triangle without adding a new hazard:<\/p>\n<ul><li><strong>Offices, corridors and general stores:<\/strong> mostly Class A with electrical equipment, so ABC powder.<\/li><li><strong>Electrical and server rooms:<\/strong> Class C; CO2 is preferred because it is non-conductive and leaves no residue.<\/li><li><strong>Fuel and oil stores, maintenance workshops:<\/strong> Class B; foam or dry powder.<\/li><li><strong>Commercial kitchens:<\/strong> Class K; a wet chemical extinguisher alongside the hood suppression system.<\/li><li><strong>Light-metal machining shops:<\/strong> Class D; a unit listed for that metal.<\/li><\/ul>\n<p>Quantities, sizes and travel distances come from the design documents. The Saudi Fire Code SBC 801 is the mandatory framework, with the 2024 edition of the Saudi Building Code mandatory since 30 June 2025, and NFPA 10 (2026 edition) is a technical reference the designer adopts. The SASO Technical Regulation for Fire Control Materials and Equipment requires a certificate of conformity for extinguishers, issued through the SABER platform.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26e20f4 elementor-widget elementor-widget-text-editor\" data-id=\"26e20f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Falcon Gold extinguishers from AZEIDK<\/h2>\n<p>AZEIDK supplies Falcon Gold extinguishers covering the most common classes: ABC dry powder in 1 and 6 kg plus a 50 kg wheeled unit, CO2 in 6 and 10 kg, 25 litre AFFF foam, and a 6 kg gas extinguisher. Types and sizes are in the <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguisher catalogue<\/a>, with the datasheet available for each type. AZEIDK&#8217;s maintenance team inspects and services extinguishers under our <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance contracts<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42cae40 elementor-widget elementor-widget-text-editor\" data-id=\"42cae40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes when matching extinguishers to fire classes<\/h2>\n<ul><li>Relying only on ABC powder in a commercial kitchen with deep fat fryers.<\/li><li>Using water or foam on an electrical panel before isolating the power.<\/li><li>Placing only CO2 in a carton and timber store, although Class A needs cooling or coating.<\/li><li>Assuming the C on an ISO-rated extinguisher means electrical, when it means gases in that system.<\/li><li>Using a standard powder extinguisher on magnesium or aluminium swarf in a machine shop.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aeb5a30 elementor-widget elementor-widget-text-editor\" data-id=\"aeb5a30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What are the elements of the fire triangle?<\/h3><\/summary><p>Fuel, heat and oxygen. The fire tetrahedron adds a fourth, the chemical chain reaction. Removing any one puts the fire out.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What are the fire extinguisher classes?<\/h3><\/summary><p>Under NFPA 10 there are five: A for ordinary solids, B for flammable liquids and gases, C for energized electrical equipment, D for metals and K for cooking oils.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is a class B fire extinguisher?<\/h3><\/summary><p>One rated for flammable liquid fires such as petrol, oils and solvents. Examples are AFFF foam, dry powder and CO2.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is a class C fire extinguisher?<\/h3><\/summary><p>Under US rating, one with a non-conductive agent that is safe on live equipment, such as CO2 or dry powder. Under ISO, C means flammable gases.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is there one extinguisher for every type of fire?<\/h3><\/summary><p>No. ABC powder covers three classes only. Metal fires need a special powder, and cooking oil fires need a wet chemical extinguisher.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the best extinguisher for a home?<\/h3><\/summary><p>Usually a small ABC dry powder unit, because it covers ordinary materials, liquids and electrical appliances found at home. Never use water on burning oil.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65ca761 elementor-widget elementor-widget-text-editor\" data-id=\"65ca761\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>The fire triangle explains how every extinguisher works, and fire classes tell you which side can be removed safely in each place. Identify the fuel, read the label in the context of its rating system, then place extinguishers by the real hazard.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-01397c7 elementor-widget elementor-widget-text-editor\" data-id=\"01397c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need the right extinguisher for each area of your facility?<\/strong> Send us the activity and floor areas, and we will propose Falcon Gold types and sizes with datasheets. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-545e0e1 elementor-widget elementor-widget-text-editor\" data-id=\"545e0e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.osha.gov\/etools\/evacuation-plans-procedures\/emergency-standards\/portable-extinguishers\/about\" rel=\"noopener\" target=\"_blank\">Portable Fire Extinguishers: Extinguisher Basics<\/a> (OSHA), <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/iso\/b09c882d-0fea-4fa0-ae37-610faf4e11e9\/iso-3941-2026\" rel=\"noopener\" target=\"_blank\">ISO 3941:2026 Classification of fires<\/a> (ISO via iTeh), <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/iso\/a69f716e-6043-48a1-8ff8-3bd0ad542dbb\/iso-3941-2007\" rel=\"noopener\" target=\"_blank\">ISO 3941:2007 Classification of fires<\/a> (ISO via iTeh), <a href=\"https:\/\/www.amerex-fire.com\/learning-center\/flashpoint\/understanding-class-d-fires-and-the-benefits-of-specialized-extinguishing-agents\/\" rel=\"noopener\" target=\"_blank\">Understanding Class D Fires<\/a> (Amerex), <a href=\"https:\/\/ohsonline.com\/articles\/2022\/04\/01\/the-abcs-d-and-ks-of-fire-extinguishers.aspx?Page=2&amp;m=1\" rel=\"noopener\" target=\"_blank\">The ABCs, D, and Ks of Fire Extinguishers<\/a> (Occupational Health &amp; Safety), <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-10-standard-development\/10\" rel=\"noopener\" target=\"_blank\">NFPA 10 Standard Development<\/a> (NFPA), and the NFPA 10 fire class definitions as reproduced in the City of Southaven guide for choosing extinguishers for commercial occupancies (PDF, cited as text).<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The fire triangle and fire extinguisher classes A, B, C, D and K: how each extinguisher works, which suits each class, and why C differs in NFPA 10 and ISO.<\/p>\n","protected":false},"author":0,"featured_media":24702,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-24706","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=24706"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24706\/revisions"}],"predecessor-version":[{"id":24722,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24706\/revisions\/24722"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24702"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=24706"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=24706"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=24706"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=24706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}