{"id":24637,"date":"2026-11-13T02:16:24","date_gmt":"2026-11-12T23:16:24","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-13T03:06:46","modified_gmt":"2026-11-13T00:06:46","slug":"kitchen-suppression-recharge-after-discharge","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/kitchen-suppression-recharge-after-discharge\/","title":{"rendered":"Kitchen Suppression Recharge After Discharge: Cleanup and Reset Before Reopening"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"24637\" class=\"elementor elementor-24637 elementor-24636 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bacdef0 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"bacdef0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-039bd07 elementor-widget elementor-widget-text-editor\" data-id=\"039bd07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">Kitchen suppression recharge after a discharge is not a single job. It is a sequence: make the kitchen safe and call a technician authorised by the manufacturer, clean the agent off within 24 hours, replace the detection element that operated, refill the cylinder with the system&#8217;s own agent, then reset the gas valve by hand and test the system. The restaurant should not cook again until all of this is done and recorded in the fire safety log book. This guide sets out the steps in order, as the manufacturers&#8217; manuals describe them, and separates what the owner does from what the technician does, for <a href=\"\/en\/sa\/solutions\/kitchen-fire-suppression-systems\/\">kitchen fire suppression systems<\/a> such as ANSUL, Hood Safer and American Fire Control.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a21ac3 elementor-widget elementor-widget-text-editor\" data-id=\"3a21ac3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>The ANSUL R-102 Owner&#8217;s Guide says to call the authorised distributor immediately after a discharge to inspect and recharge the system and to find the cause.<\/li>\n<li>Clean up within 24 hours using warm water and detergent, and throw away any food or grease the agent touched.<\/li>\n<li>The 2015 International Fire Code (IFC) makes fuel and power reset manual and requires the system to be serviced after every activation.<\/li>\n<li>In Hood Safer systems, wet chemical refill containers are single use, and discharge piping is flushed with hot water.<\/li>\n<li>Do not reopen the gas valve yourself before the system has been reset and tested.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2eab01f elementor-widget elementor-widget-text-editor\" data-id=\"2eab01f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What happens when a kitchen suppression system discharges?<\/h2>\n<p>When the system operates, either automatically through the fusible link above the appliances or manually from the pull station, wet chemical agent discharges from the nozzles onto the cooking surfaces and into the hood and duct. The agent is an alkaline solution. In Hood Safer, for example, it is a potassium carbonate solution with a pH above 11, according to the safety data sheet in the submittal. It reacts with hot oil to form a soapy layer that cuts it off from the air and cools it.<\/p>\n<p>At the same moment the heat source is cut. IFC 2015 Section 904.12.2 states that actuation of the extinguishing system shall automatically shut down the fuel or electrical supply to the cooking equipment, and that the reset shall be manual. The IFC is the model on which the 2018 edition of the Saudi fire code, SBC 801, was built, so the same principle appears in specifications and consultant requirements.<\/p>\n<p>The result is a kitchen at a standstill, surfaces covered in an alkaline agent, an empty cylinder, and a fused link or a used pull station. Each of these needs action before the kitchen goes back to work.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c97b3e elementor-widget elementor-widget-text-editor\" data-id=\"5c97b3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Step by step after a kitchen suppression discharge<\/h2>\n<ol>\n<li><strong>Make sure the fire is out and get staff out.<\/strong> If any flame remains, use the kitchen (Class K) extinguisher and call Civil Defense. Do not open the duct or hood while it is hot.<\/li>\n<li><strong>Leave gas and power off.<\/strong> Do not open the gas valve or reset the breaker to finish cooking. The reset comes later and is done by the technician.<\/li>\n<li><strong>Call the authorised technician at once.<\/strong> The ANSUL guide says to call the authorised distributor immediately after discharge to inspect and recharge the system and to have the distributor determine the cause. It also says no one except an authorised distributor should maintain the system.<\/li>\n<li><strong>Take photos and notes.<\/strong> Time, the appliance where the fire started, and whether operation was automatic or manual. This helps the technician find the cause and belongs in the <a href=\"\/en\/sa\/media-center\/fire-safety-log-book-records-inspection\/\">fire safety log book<\/a>.<\/li>\n<li><strong>Clean up within 24 hours.<\/strong> The ANSUL guide says cleanup should take place within 24 hours of discharge using warm water and detergent, and that food and grease that contacted the agent should be discarded. Wear gloves, as the agent is alkaline.<\/li>\n<li><strong>Recharge and reset by the technician.<\/strong> This is covered in the next section.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0f02f2 elementor-widget elementor-widget-text-editor\" data-id=\"f0f02f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Kitchen suppression recharge: what gets replaced and what gets checked?<\/h2>\n<p>This part is for a technician trained on the same brand, because each manufacturer sets its own agent, filling method and pressure. The table brings together what the available manuals say:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Item<\/th><th>What is done<\/th><th>Source<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Cylinder and agent<\/td><td>Refilled only with the system&#8217;s own agent. In Hood Safer, wet chemical containers are used to refill discharged cylinders, and each container is single use<\/td><td>Hood Safer installation manual, 3.11<\/td><\/tr>\n<tr><td>Cylinder pressure<\/td><td>Hood Safer cylinder pressure is 15 bar and is re-pressurised if lower<\/td><td>Hood Safer installation manual, 4.8<\/td><\/tr>\n<tr><td>Discharge piping and nozzles<\/td><td>Pipes flushed inside with hot water after activation; nozzles checked for blockage<\/td><td>Hood Safer installation manual, 4.10<\/td><\/tr>\n<tr><td>Detection element<\/td><td>A fused link does not work again; a new element with the temperature rating set in the system manual is fitted<\/td><td>Each manufacturer&#8217;s manual<\/td><\/tr>\n<tr><td>Gas valve<\/td><td>Reopened by hand after the system is reset. In Hood Safer, the tension gear is turned until it stops, which means the valve is open<\/td><td>Hood Safer installation manual, 3.9; IFC 2015, 904.12.2<\/td><\/tr>\n<tr><td>Service after activation<\/td><td>Service after every activation, on top of routine service at least every six months<\/td><td>IFC 2015, 904.12.6.2; ANSUL guide<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>After recharging, the technician tests the manual pull station, the gas and power shutoff, and the connection to the fire alarm panel where there is one. ANSUL R-102 and American Fire Control each have their own manuals, and each product&#8217;s manual is followed as written. See the <a href=\"\/en\/sa\/products\/ansul-r-102-restaurant-fire-suppression-system\/\">ANSUL R-102 system<\/a>, the <a href=\"\/en\/sa\/products\/american-fire-control-kitchen-fire-suppression-system\/\">American Fire Control kitchen system<\/a> and the <a href=\"\/en\/brand\/hood-safer\/\">Hood Safer brand page<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c35f4e5 elementor-widget elementor-widget-text-editor\" data-id=\"c35f4e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Who does what after a discharge?<\/h2>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Task<\/th><th>Owner or restaurant manager<\/th><th>Authorised technician<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Evacuate and secure the kitchen<\/td><td>Yes<\/td><td>No<\/td><\/tr>\n<tr><td>Discard food and oil the agent touched<\/td><td>Yes<\/td><td>No<\/td><\/tr>\n<tr><td>Clean surfaces within 24 hours<\/td><td>Yes<\/td><td>Advises if needed<\/td><\/tr>\n<tr><td>Find the cause of operation<\/td><td>Provides information<\/td><td>Yes<\/td><\/tr>\n<tr><td>Refill cylinder and replace detection element<\/td><td>No<\/td><td>Yes<\/td><\/tr>\n<tr><td>Reset gas valve and test system<\/td><td>No<\/td><td>Yes<\/td><\/tr>\n<tr><td>Record the event and service in the log book<\/td><td>Yes<\/td><td>Hands over a service report<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1869518 elementor-widget elementor-widget-text-editor\" data-id=\"1869518\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When can the restaurant reopen?<\/h2>\n<p>When four things are true together: surfaces and hood are clean of agent, the cylinder is refilled and pressurised to its manual, the new detection element is fitted, and gas and power shutoff and restoration have been tested. Until then the kitchen has no protection, and a second fire would find no system to put it out.<\/p>\n<p>If the discharge was caused by a real fire in the duct or filters, ask the technician to check the hood, filters and duct before restart, because built-up grease was often part of the cause. If it was accidental, such as a pulled station or excess heat from a new appliance, the question is whether the protection design still suits the current appliance layout. IFC 2015 Section 904.12.6.1 requires the system to be brought into compliance when the cooking media, appliance positions or appliances change.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4461056 elementor-widget elementor-widget-text-editor\" data-id=\"4461056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes after a kitchen suppression discharge<\/h2>\n<ul>\n<li>Opening the gas valve by hand to resume cooking before the technician arrives.<\/li>\n<li>Leaving the agent on surfaces for more than a day, which makes removal harder.<\/li>\n<li>Refilling the cylinder with another brand&#8217;s agent or an agent of unknown origin.<\/li>\n<li>Refitting the old link, or a link with a different temperature rating.<\/li>\n<li>Not looking for the cause, so the system operates again.<\/li>\n<li>Not recording the event, leaving no evidence at the next inspection.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1210909 elementor-widget elementor-widget-text-editor\" data-id=\"1210909\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>How long does a kitchen suppression recharge take?<\/h3><\/summary><p>It depends on whether the original agent and detection parts for your system are available, and on how much cleaning is needed. There is no fixed time, so ask your service provider in advance whether refill containers for your system are in stock.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What should I do right after the kitchen system discharges?<\/h3><\/summary><p>Get staff out, leave gas and power off and call the authorised technician. Then clean surfaces with warm water and detergent within 24 hours and discard any food the agent touched.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is wet chemical agent harmful to staff?<\/h3><\/summary><p>It is an alkaline solution, so wear gloves, avoid contact with skin and eyes, and rinse anything it touches with water. Check the safety data sheet (MSDS) for the agent in your system.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Can the system be refilled with another manufacturer&#8217;s agent?<\/h3><\/summary><p>No. Each system is tested and listed with its own agent, and each manufacturer&#8217;s manual defines the agent and the filling method. Using a different agent takes the system outside its approval.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Do fusible links need replacing after every discharge?<\/h3><\/summary><p>The link that fused must be replaced. The technician checks the other elements to the system manual. The ANSUL guide calls for metal fusible links to be replaced every six months, and the Hood Safer manual calls for detectors to be replaced every year.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Does routine maintenance cover service after a discharge?<\/h3><\/summary><p>No. IFC 2015 requires service at least every six months and also after every activation. A routine maintenance contract covers scheduled visits; a discharge needs its own visit.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b840447 elementor-widget elementor-widget-text-editor\" data-id=\"b840447\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>After a kitchen suppression discharge, safety comes first, then the authorised technician, then cleanup within 24 hours. The recharge uses the original agent, the detection element is replaced, and gas is reset by hand and the system tested before the first order goes out. AZEIDK provides <a href=\"\/en\/sa\/services\/corrective-maintenance-technical-support\/\">corrective maintenance and technical support<\/a> and <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance contracts<\/a> for fire systems, and its kitchen system services include refilling and technical follow-up when needed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34f508e elementor-widget elementor-widget-text-editor\" data-id=\"34f508e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Has your kitchen system discharged?<\/strong> Send the system type and photos of the cylinder and hood, and we will arrange inspection and recharge with you. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d54050d elementor-widget elementor-widget-text-editor\" data-id=\"d54050d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> ANSUL, Owner&#8217;s Guide, R-102 Restaurant Fire Suppression System (Part No. 418127-03) (https:\/\/content.greenheck.com\/public\/DAMProd\/Original\/10011\/418127_ansul_iom.pdf); Hood Safer material submittal on the AZEIDK website, installation manual sections 3.9, 3.11, 4.3, 4.4, 4.8, 4.10 and safety data sheet (https:\/\/azeidkgroup.com\/wp-content\/uploads\/2024\/08\/Material-Submittal-for-Fire-Suppression-System-Hood-Safer.pdf); International Fire Code 2015, Section 904.12 (https:\/\/assets.lawrenceks.org\/fire-medical\/files\/2015%20IFC%20SECTION%20904.12.pdf).<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Kitchen suppression recharge after a discharge: cleanup within 24 hours, replacing the fused link, refilling with the original agent and resetting the gas.<\/p>\n","protected":false},"author":0,"featured_media":24601,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-24637","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=24637"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24637\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24601"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=24637"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=24637"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=24637"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=24637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}