{"id":24629,"date":"2026-11-13T02:20:24","date_gmt":"2026-11-12T23:20:24","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-13T03:06:57","modified_gmt":"2026-11-13T00:06:57","slug":"fire-valves-price-cost-factors-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-valves-price-cost-factors-saudi\/","title":{"rendered":"Fire Valve Price in Saudi Arabia: What Drives the Cost (OS&amp;Y vs Butterfly, Flanged vs Grooved, Size, UL\/FM)"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"24629\" class=\"elementor elementor-24629 elementor-24628 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8b4d5da e-con-full az-el-article e-flex e-con e-parent\" data-id=\"8b4d5da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1708c44 elementor-widget elementor-widget-text-editor\" data-id=\"1708c44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">The fire valve price you get in Saudi Arabia is never a single figure. The cost of a fire protection valve depends on its type, size, end connection (flanged or grooved), working pressure, UL or FM listing and whether a supervisory switch is included. Two quotes can only be compared when the model, size, approval and end type match. This article explains each factor that moves the price and shows how to read valve quotations on Saudi projects, using the <a href=\"\/en\/brand\/afc\/\">American Fire Control (AFC)<\/a> valves supplied by AZEIDK as examples.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-018cb36 elementor-widget elementor-widget-text-editor\" data-id=\"018cb36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>The two biggest price drivers are valve type (OS&amp;Y, butterfly, check or alarm check) and nominal size.<\/li>\n<li>Flanged and grooved ends change the price of the valve and of the couplings, gaskets and bolts it needs.<\/li>\n<li>A UL Listed or FM Approved valve comes with documents that can be verified, which is what consultants usually ask for in the submittal.<\/li>\n<li>A butterfly valve with a built-in supervisory switch covers an item that may be priced separately for other valves.<\/li>\n<li>Compare quotes line by line: model, size, pressure, approval, ends, accessories, and supply only or supply and install.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8222b7c elementor-widget elementor-widget-text-editor\" data-id=\"8222b7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What drives the fire valve price in Saudi Arabia?<\/h2>\n<p>When a supplier prices the valves for a fire fighting network, several elements are counted at once. Knowing them explains why two quotes for the same quantity differ, and keeps you from accepting a cheaper offer that later fails to match the drawings or gets rejected by the consultant.<\/p>\n<h3>1. Valve type and its role in the network<\/h3>\n<p>Each type has a different internal design and parts count, so manufacturing cost differs. The main types on fire networks:<\/p>\n<ul>\n<li><strong>OS&amp;Y gate valve (outside screw and yoke):<\/strong> the stem rises when the valve opens, so its position is visible. Common in pump rooms and on main supply lines.<\/li>\n<li><strong>Butterfly valve:<\/strong> grooved ends or a wafer body fitted between two flanges, usually with a gear operator and position indicator.<\/li>\n<li><strong>Check valve:<\/strong> stops reverse flow, installed at the fire pump and the fire department connection. See our article on the <a href=\"\/en\/sa\/media-center\/afc-swing-check-valve-fire-network\/\">swing check valve for fire networks<\/a>.<\/li>\n<li><strong>NRS gate valve with indicator post (PIV):<\/strong> for buried mains; the price covers both the valve and the post.<\/li>\n<li><strong>Wet alarm check valve:<\/strong> a full assembly with trim (gauges, pressure or flow switch, drain), so it cannot be compared with a plain valve.<\/li>\n<\/ul>\n<h3>2. Nominal size<\/h3>\n<p>Larger sizes mean more body weight, more material and higher freight. An 8 inch valve cannot be compared with a 4 inch valve of the same type. The BOQ should list valves by size, not as one line called &#8220;fire valves&#8221;.<\/p>\n<h3>3. Flanged or grooved ends<\/h3>\n<p>End type sets the installation method and what comes with it. A flanged valve needs mating flanges, gaskets and bolts; a grooved valve needs grooved couplings on both sides. Compare the valve together with its installation accessories. For example, AFC model A-3000 has flanged ends and AG-3000 has grooved ends; both are on the <a href=\"\/en\/sa\/products\/american-afc-osy-fire-gate-valve-with-flanged-or-grooved-ends-a-3000-and-ag-3000\/\">AFC OS&amp;Y gate valve page<\/a>.<\/p>\n<h3>4. Working pressure and flange standard<\/h3>\n<p>Valves differ in maximum working pressure and in flange standard (for example ANSI Class 125, Class 150 or PN16). The valve must suit the actual system pressure downstream of the pump, and its flanges must match the adjoining pipe and equipment. If two quotes use different flange standards, you are comparing different products.<\/p>\n<h3>5. UL and FM approval<\/h3>\n<p>A valve listed by UL or approved by FM Approvals has been tested by an independent body, and the datasheet comes with evidence of that. This shows in the price and in whether the consultant accepts the submittal. Ask for the approval to be stated per model and size, as a listing may not cover every size. For brand and approval background see <a href=\"\/en\/sa\/media-center\/sprinkler-valve-grooved-fitting-brands-saudi\/\">sprinkler valve and grooved fitting brands in Saudi Arabia<\/a>.<\/p>\n<h3>6. Supervisory (tamper) switch<\/h3>\n<p>A valve controlling the water supply must stay open. According to the National Fire Sprinkler Association (NFSA), NFPA 13 (2022 edition, Section 16.9.3.3.1) gives four ways to supervise control valves: signaling to a monitoring station, a local signal at a constantly attended location, locking the valve in the correct position, or keeping it inside an owner-controlled fenced enclosure, sealed open and inspected weekly. Most buildings use electrical supervision, which brings a switch into the cost. Some butterfly valves include a built-in switch, such as AFC BFG-300 and BFG-301, while an OS&amp;Y valve needs a separate switch mounted on it. For connecting switches to the fire alarm panel, see <a href=\"\/en\/sa\/media-center\/addressable-switch-monitor-sprinkler-flow-valve\/\">monitoring flow and valve switches<\/a>.<\/p>\n<h3>7. Materials and coating<\/h3>\n<p>Body material (ductile iron, for instance), stem material (stainless steel), EPDM encapsulation of the disc or wedge, and internal and external epoxy coating all affect price and service life in standing water. These details are on the datasheet, so ask for it with the quote.<\/p>\n<h3>8. Quantity, stock and lead time<\/h3>\n<p>Larger quantities leave room to negotiate. Large sizes or models not held locally may need importing with a longer lead time. Ask what is in stock and the delivery time for the rest, because one late valve can hold up the pressure test of the whole network.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0eb1f71 elementor-widget elementor-widget-text-editor\" data-id=\"0eb1f71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire valve types compared by cost factors<\/h2>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Type<\/th><th>Typical use<\/th><th>What the price includes<\/th><th>What to check in the quote<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>OS&amp;Y gate valve<\/td><td>Pump rooms, supply mains<\/td><td>Valve, end flanges or couplings, switch if requested<\/td><td>Flanged or grooved, size, pressure, UL\/FM<\/td><\/tr>\n<tr><td>Grooved butterfly valve<\/td><td>Risers, large branch lines<\/td><td>Valve with gear operator, often a built-in switch<\/td><td>Built-in switch, size, approval<\/td><\/tr>\n<tr><td>Wafer butterfly valve<\/td><td>Between two flanges<\/td><td>Valve, long bolts and gaskets<\/td><td>Flange standard, switch, approval<\/td><\/tr>\n<tr><td>Check valve<\/td><td>Fire pump, fire department connection<\/td><td>Valve only, flanged or grooved<\/td><td>Flow direction, ends, approval<\/td><\/tr>\n<tr><td>NRS valve with indicator post<\/td><td>Buried mains<\/td><td>Valve, post and accessories<\/td><td>Post length to suit main depth<\/td><\/tr>\n<tr><td>Wet alarm check valve<\/td><td>Start of each wet sprinkler system<\/td><td>Valve with trim set<\/td><td>Exact contents of the trim<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed5a6f elementor-widget elementor-widget-text-editor\" data-id=\"1ed5a6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why does an OS&amp;Y valve price differ from a butterfly valve?<\/h2>\n<p>Contractors often ask which is cheaper. There is no fixed rule across all sizes, so compare both at the same size and end type. The cost gap comes from a few clear points:<\/p>\n<ul>\n<li><strong>Space:<\/strong> an OS&amp;Y valve needs headroom for the rising stem, while a butterfly valve is shorter face to face. In a tight pump room this can change the pipe layout itself.<\/li>\n<li><strong>Supervision:<\/strong> if the butterfly valve has a built-in switch, add the cost of a separate switch for the OS&amp;Y valve when comparing.<\/li>\n<li><strong>Specification:<\/strong> some consultants specify the valve type for certain locations. If the specification calls for OS&amp;Y, do not swap to butterfly for price without written approval.<\/li>\n<\/ul>\n<p>For AFC OS&amp;Y details read <a href=\"\/en\/sa\/media-center\/afc-osy-gate-valves-saudi\/\">AFC OS&amp;Y gate valves in Saudi Arabia<\/a>, and for where each valve sits in the network see the <a href=\"\/en\/sa\/media-center\/fire-protection-valves-network-components-guide\/\">fire protection valves and network components guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ea4ef5 elementor-widget elementor-widget-text-editor\" data-id=\"7ea4ef5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to compare fire valve quotations<\/h2>\n<p>Put the quotes in one table and check these points for every line:<\/p>\n<ol>\n<li><strong>Brand and full model number:<\/strong> &#8220;6 inch butterfly valve&#8221; is not enough.<\/li>\n<li><strong>Size and end type:<\/strong> flanged or grooved, and the flange standard where relevant.<\/li>\n<li><strong>Working pressure:<\/strong> taken from the datasheet and suitable for the system.<\/li>\n<li><strong>Approval:<\/strong> UL Listed, FM Approved or both, with evidence.<\/li>\n<li><strong>Accessories:<\/strong> supervisory switch, gear operator, indicator post, couplings, gaskets and bolts.<\/li>\n<li><strong>Documents:<\/strong> datasheet, certificate of origin, approval evidence and a submittal file where material approval is needed.<\/li>\n<li><strong>Scope:<\/strong> supply only, or supply, installation and testing. These cannot be compared directly.<\/li>\n<li><strong>Lead time and warranty:<\/strong> when each item arrives and what the warranty covers.<\/li>\n<\/ol>\n<p>On conformity with the Saudi Standards, Metrology and Quality Organization (SASO), ask the supplier whether the product falls under a technical regulation that needs a certificate of conformity through the SABER platform, and request it where it applies. For comparing full system offers, see <a href=\"\/en\/sa\/media-center\/compare-fire-system-quotations\/\">how to compare fire system quotations<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a92ade elementor-widget elementor-widget-text-editor\" data-id=\"9a92ade\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Mistakes that raise the cost after purchase<\/h2>\n<ul>\n<li>Buying a flanged valve whose flange standard does not match the pump or pipe flange, then paying for an adaptor.<\/li>\n<li>Choosing an unlisted valve, getting the submittal rejected and reordering.<\/li>\n<li>Leaving the supervisory switch out of the quote and adding it later at a separate price.<\/li>\n<li>Installing a check valve against the flow arrow, which shows up at commissioning and costs a removal and refit.<\/li>\n<li>Storing valves on site without protection from dust and sun, so gaskets or coating are damaged before installation.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4f719b elementor-widget elementor-widget-text-editor\" data-id=\"c4f719b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>AFC fire valves from AZEIDK<\/h2>\n<p>AZEIDK supplies American Fire Control valves in Saudi Arabia through its <a href=\"\/en\/sa\/services\/technical-supply-of-fire-safety-systems\/\">technical supply service<\/a>. From the published product pages:<\/p>\n<ul>\n<li><strong>OS&amp;Y gate valve A-3000 (flanged) and AG-3000 (grooved):<\/strong> sizes 2.5 to 12 inch, maximum working pressure 300 psi (21 bar), UL Listed and FM Approved per the manufacturer&#8217;s catalogue.<\/li>\n<li><strong>Grooved butterfly valve BFG-300 and BFG-301:<\/strong> sizes 2 to 12 inch, working pressure 300 psi, built-in supervisory switch and gear operator, UL Listed and FM Approved per the catalogue. Product page: <a href=\"\/en\/sa\/products\/american-afc-grooved-fire-butterfly-valve-bfg-300-and-bfg-301\/\">AFC grooved butterfly valve<\/a>.<\/li>\n<li><strong><a href=\"\/en\/sa\/products\/american-afc-wafer-type-fire-butterfly-valve-bfw-300\/\">Wafer butterfly valve BFW-300<\/a><\/strong>, and the <strong><a href=\"\/en\/sa\/products\/american-afc-nrs-flanged-fire-gate-valve-a-3100\/\">NRS gate valve A-3100<\/a><\/strong> with the <strong><a href=\"\/en\/sa\/products\/american-afc-vertical-indicator-post-model-5100\/\">vertical indicator post 5100<\/a><\/strong>.<\/li>\n<li><strong>Check valves:<\/strong> <a href=\"\/en\/sa\/products\/american-afc-flanged-swing-check-valve-a-3150\/\">A-3150 flanged<\/a> and <a href=\"\/en\/sa\/products\/american-afc-grooved-swing-check-valve-a-3500\/\">A-3500 grooved<\/a>, plus the <a href=\"\/en\/sa\/products\/american-afc-wet-alarm-check-valve-acv-300-series\/\">ACV-300 wet alarm check valve<\/a>.<\/li>\n<\/ul>\n<p>If you are unsure which valve suits each point in the network, our <a href=\"\/en\/sa\/services\/technical-selection-of-systems-equipment\/\">technical selection of systems and equipment<\/a> team can review the drawings and BOQ with you before pricing. All products are on the <a href=\"\/en\/sa\/products\/\">products page<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90298cf elementor-widget elementor-widget-text-editor\" data-id=\"90298cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>How much does a fire valve cost?<\/h3><\/summary><p>There is no single price. It depends on type, size, end connection, pressure rating, approval and accessories. Send a BOQ with sizes and models to get an accurate quote.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What makes one fire valve more expensive than another of the same type?<\/h3><\/summary><p>A larger size, UL or FM approval, a built-in supervisory switch, internal and external epoxy coating, and a higher-pressure flange class.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is an OS&amp;Y valve more expensive than a butterfly valve?<\/h3><\/summary><p>There is no fixed rule. Compare both at the same size and end type, and add a separate supervisory switch to the OS&amp;Y price if the butterfly valve has one built in.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Should I choose a flanged or a grooved valve?<\/h3><\/summary><p>Choose what matches the pipe joining method on the drawings. Grooved valves fit grooved couplings; flanged valves need mating flanges of the same standard. Include accessories when comparing.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Will a consultant accept a valve without UL or FM approval?<\/h3><\/summary><p>That depends on the project specification. Many fire protection specifications call for listed or approved products, so check before buying and request the approval evidence with the datasheet.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Does an alarm check valve price include all the trim?<\/h3><\/summary><p>Not always. Ask the quote to list the trim in detail: gauges, alarm switch, drain line and retard chamber where used.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How do I get a fire valve quote from AZEIDK?<\/h3><\/summary><p>Send the BOQ or drawings with sizes, end types and required approvals through the contact page, and the technical team will reply with an itemised quote.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ea0b30 elementor-widget elementor-widget-text-editor\" data-id=\"0ea0b30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>The fire valve price comes from technical choices: type, size, ends, pressure, approval and accessories. The cheapest quote is only cheaper if it covers the same items. Define these in the BOQ first, compare offers line by line, and make sure the documents are enough for the consultant&#8217;s material approval and for <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dcb84da elementor-widget elementor-widget-text-editor\" data-id=\"dcb84da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need a price for fire network valves?<\/strong> Send your BOQ and sizes and we will review them with you. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4540e9 elementor-widget elementor-widget-text-editor\" data-id=\"c4540e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> American Fire Control product pages on the AZEIDK website (A-3000\/AG-3000 and BFG-300\/BFG-301); National Fire Sprinkler Association (NFSA), &#8220;Fire Sprinkler Monitoring &amp; Supervision: NFPA 13 and NFPA 72&#8221;, February 2023 (https:\/\/nfsa.org\/2023\/02\/03\/fire-sprinkler-monitoring-supervision\/).<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire valve price in Saudi Arabia: how valve type, size, flanged or grooved ends, UL\/FM approval and supervisory switches change cost, and how to compare.<\/p>\n","protected":false},"author":0,"featured_media":24540,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-24629","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24629","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=24629"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24629\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24540"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=24629"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=24629"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=24629"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=24629"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}