{"id":24607,"date":"2026-11-13T02:31:24","date_gmt":"2026-11-12T23:31:24","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-13T03:07:47","modified_gmt":"2026-11-13T00:07:47","slug":"access-control-system-cost-door-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/access-control-system-cost-door-saudi\/","title":{"rendered":"Door Access Control System Cost in Saudi Arabia: Reader, Lock, Exit Button, Controller and Software"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"24607\" class=\"elementor elementor-24607 elementor-24606 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-60877de e-con-full az-el-article e-flex e-con e-parent\" data-id=\"60877de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-88d7a06 elementor-widget elementor-widget-text-editor\" data-id=\"88d7a06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">Door access control system cost in Saudi Arabia is built from five core parts per door: the reader, the electric lock, the exit button, the controller and the software, plus the power supply, cabling and installation. What raises the price most is the credential type (card, fingerprint or face), the lock that suits the door, the number of networked doors, and the need to release doors automatically on fire alarm. AZEIDK supplies access control devices from Hikvision, Dahua and ZKTeco as part of its <a href=\"\/en\/sa\/solutions\/security-surveillance-systems\/\">security and surveillance systems<\/a>, with supply and installation to suit each site.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42883fc elementor-widget elementor-widget-text-editor\" data-id=\"42883fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul>\n<li>A single door usually needs a reader, electric lock, exit button, door contact, controller and power supply.<\/li>\n<li>Face and fingerprint readers cost more than card readers, and the lock depends on the door (glass, timber or steel).<\/li>\n<li>A networked controller and software add upfront cost but make many doors far easier to manage.<\/li>\n<li>Electrically locked egress doors must release on power loss and on fire alarm. This is a design and cost item, not something to leave to the end.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5b8e8a elementor-widget elementor-widget-text-editor\" data-id=\"e5b8e8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What determines door access control system cost?<\/h2>\n<p>Many owners ask for an &#8220;access control system price&#8221; as if it were one device. In practice it is a set of parts fitted at the door and in the equipment room. The table shows each part and what changes its cost. There are no prices, because these vary with brand, quantity and site conditions.<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Component<\/th><th>Function<\/th><th>What raises its cost<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Reader<\/td><td>Identifies the user<\/td><td>Face or fingerprint recognition, outdoor use, readers on both sides of the door<\/td><\/tr>\n<tr><td>Electric lock<\/td><td>Locks and releases the door on the controller&#8217;s command<\/td><td>Glass or heavy doors, special brackets, required holding force<\/td><\/tr>\n<tr><td>Exit and emergency buttons<\/td><td>Release the door from inside<\/td><td>Touchless exit buttons, an extra break glass unit<\/td><\/tr>\n<tr><td>Controller<\/td><td>Decides who enters and when<\/td><td>Number of doors, network connection, user and event capacity<\/td><\/tr>\n<tr><td>Software<\/td><td>Manages permissions and reports<\/td><td>Licences per door, integration with time attendance or CCTV<\/td><\/tr>\n<tr><td>Power supply and battery<\/td><td>Powers the lock and controller<\/td><td>Standby battery, several locks on one supply<\/td><\/tr>\n<tr><td>Cabling and installation<\/td><td>Connects everything<\/td><td>Existing building, long runs, conduit and finishing work<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d61551 elementor-widget elementor-widget-text-editor\" data-id=\"5d61551\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Reader: card, fingerprint or face?<\/h2>\n<p>The reader is the part users see, and it causes most of the difference between quotations. Common types:<\/p>\n<ul>\n<li><strong>Card reader:<\/strong> usually the simplest and lowest cost. Two frequencies are common: 125 kHz (ID) and 13.56 MHz (IC). Cards are a recurring item priced per employee.<\/li>\n<li><strong>Fingerprint with card and PIN:<\/strong> for example the <a href=\"\/en\/sa\/products\/zkteco-x100-and-x101\/\">ZKTeco X100 and X101<\/a>. According to the product page they support fingerprint, card and PIN on a touch keypad, are rated IP66, and have interfaces for an electric lock, door sensor and exit button.<\/li>\n<li><strong>Face recognition:<\/strong> usually the highest cost, used when you need touchless identification or a link to time attendance.<\/li>\n<\/ul>\n<p>Do you need a reader on both sides? If you must log both entry and exit, each door needs two readers, which roughly doubles reader cost. If exit is free, an exit button inside is enough.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2bbc9e2 elementor-widget elementor-widget-text-editor\" data-id=\"2bbc9e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Electric lock: the door decides, not the price<\/h2>\n<p>Lock selection starts with the door itself: its material, swing direction, and whether it is on an escape route. Common types on the market:<\/p>\n<ul>\n<li><strong>Magnetic lock (maglock):<\/strong> common on glass, timber and steel doors. It releases when power is cut, which is called fail-safe. Frameless glass doors may need special brackets.<\/li>\n<li><strong>Electric strike:<\/strong> fitted in the door frame with a mechanical lockset. Some versions stay locked on power loss (fail-secure), which limits where they can be used on escape doors.<\/li>\n<li><strong>Electric bolt:<\/strong> used on some glass doors and double-acting doors.<\/li>\n<\/ul>\n<p>Glass doors, heavy doors and fire-rated doors increase lock and installation cost. On a fire-rated door the lock must not reduce the door&#8217;s performance, so check it with the door supplier. Door solutions are on our <a href=\"\/en\/sa\/solutions\/fire-rated-doors-emergency-exit-solutions\/\">fire-rated doors and emergency exits<\/a> page.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8061e6 elementor-widget elementor-widget-text-editor\" data-id=\"a8061e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Exit button and emergency break glass<\/h2>\n<p>The exit button is a low-cost item that matters for safety. It is fitted inside to release the door without a card. Many projects also add a break glass unit that cuts power to the lock directly if the controller fails.<\/p>\n<p>As a technical reference, an article in Consulting-Specifying Engineer on NFPA 101 (2012 edition) requirements for access-controlled egress doors lists: a sensor that releases the door when an occupant approaches from inside; a manual release device marked &#8220;PUSH TO EXIT&#8221; within 60 inches (about 1.5 m) of the door that cuts power to the lock for at least 30 seconds; and release on loss of power and on sprinkler or fire detection activation. These are reference requirements. What applies to your building is set by the consultant under the Saudi Building Code and Civil Defense requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d1aee5 elementor-widget elementor-widget-text-editor\" data-id=\"9d1aee5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Controller: standalone or networked?<\/h2>\n<p>The controller is the brain of the system. A small office may only need a standalone unit that combines the reader and memory at the door. Larger buildings use networked controllers managed from central software.<\/p>\n<p>Example: the <a href=\"\/en\/sa\/products\/hikvision-ds-k2801-value-series-card-access-contoller\/\">Hikvision DS-K2801 controller<\/a> in AZEIDK&#8217;s range is a one-door unit with two Wiegand ports for an entry and an exit reader, capacity for 10,000 cards, TCP\/IP communication and a 12 V DC supply, according to the product page. Choosing a one-door or a multi-door controller changes the cost per door: a multi-door unit spreads its price across several doors but needs longer cable runs to each one.<\/p>\n<p>Questions that decide the right controller:<\/p>\n<ul>\n<li>How many doors now, and how many after expansion?<\/li>\n<li>Do you need to manage doors from one office or across several branches?<\/li>\n<li>How many users and how many event records must be stored?<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94cd187 elementor-widget elementor-widget-text-editor\" data-id=\"94cd187\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Access control system price: software and commissioning<\/h2>\n<p>Software is often missed when comparing quotations. Some devices ship with basic management software, while other systems need a licence that grows with the number of doors or devices. Ask the supplier directly: Is software included? Is it licensed? Does it need a dedicated PC or server?<\/p>\n<p>If you want to link access control with other <a href=\"\/en\/sa\/solutions\/low-current-systems\/\">low current systems<\/a>, such as time attendance, CCTV or turnstiles, that adds programming and integration work. For turnstiles, see our <a href=\"\/en\/sa\/media-center\/access-gates-turnstiles-guide-saudi\/\">guide to access gates and turnstiles<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5aeaf3e elementor-widget elementor-widget-text-editor\" data-id=\"5aeaf3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire alarm interface and power supply<\/h2>\n<p>Any electrically locked door on an escape route needs a reliable way to open during a fire. The common approach is a signal from the <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm panel<\/a> that cuts power to the relevant locks on alarm. This requires:<\/p>\n<ul>\n<li>An output from the fire alarm panel or an addressable module, and coordination between the fire alarm and security contractors.<\/li>\n<li>A lock power supply that the fire signal can cut, with a standby battery for the controller if records must be kept during power loss.<\/li>\n<li>A practical test at handover proving that the doors actually release when the alarm is triggered.<\/li>\n<\/ul>\n<p>Leaving this out of the quotation means extra cost later and can delay building approval.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae2e727 elementor-widget elementor-widget-text-editor\" data-id=\"ae2e727\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to read an access control quotation<\/h2>\n<ol>\n<li>Number of doors and, for each door: reader type and count, lock type, exit button, door contact.<\/li>\n<li>Brand and model of each device, with datasheets. AZEIDK supplies devices from <a href=\"\/en\/brand\/hikvision\/\">Hikvision<\/a>, <a href=\"\/en\/brand\/dahua\/\">Dahua<\/a> and <a href=\"\/en\/brand\/zkteco\/\">ZKTeco<\/a>.<\/li>\n<li>Controller type and doors per unit.<\/li>\n<li>Software: included or licensed, and the number of cards supplied.<\/li>\n<li>Power supply, battery and fire alarm interface.<\/li>\n<li>Cabling, conduit, installation, programming and training.<\/li>\n<\/ol>\n<p>A survey before pricing reveals the door types and cable routes. AZEIDK offers <a href=\"\/en\/sa\/services\/technical-site-inspection-assessment\/\">technical site inspection and assessment<\/a>, and our article on <a href=\"\/en\/sa\/media-center\/compare-fire-system-quotations\/\">comparing quotations<\/a> also helps.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a502bd6 elementor-widget elementor-widget-text-editor\" data-id=\"a502bd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\">\n<details class=\"az-faq__item\"><summary><h3>How much does access control cost per door?<\/h3><\/summary><p>There is no fixed figure. Cost depends on the reader, lock, controller, software, door condition and cabling. Request a site survey to get a detailed quotation per door.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What are the components of a door access control system?<\/h3><\/summary><p>A reader, electric lock, exit button, door contact, controller, power supply and management software, plus cabling. Some standalone devices combine the reader and controller in one unit.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Maglock or electric strike for a glass door?<\/h3><\/summary><p>A maglock with brackets that suit the glass and frame is the common choice for glass doors. The final decision depends on the door, its swing and whether it is on an escape route.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is fingerprint more expensive than card?<\/h3><\/summary><p>The reader usually costs more, but card systems carry a recurring cost for cards and replacements. Compare the cost over your number of users and the period of use.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Must the door release on fire alarm?<\/h3><\/summary><p>Electrically locked doors on escape routes need a way to release on alarm and on power loss. The exact requirement for your building is set by the consultant under the Saudi code and Civil Defense requirements.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is the software free with the devices?<\/h3><\/summary><p>It depends on the brand and system. Some devices come with basic software and some systems need a licence. Ask for this in writing in the quotation.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c42fdad elementor-widget elementor-widget-text-editor\" data-id=\"c42fdad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Access control cost is built door by door: reader, lock, exit button, controller and software, then power, cabling and the fire alarm interface. Define your needs first, ask for a detailed quotation per door, and compare offers on the same components. That way you get a system that secures the building without blocking evacuation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-041f1b2 elementor-widget elementor-widget-text-editor\" data-id=\"041f1b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need a quotation for door access control?<\/strong> Tell us the number and type of doors and the credential you want, and the AZEIDK team will prepare a detailed offer for your site. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5944961 elementor-widget elementor-widget-text-editor\" data-id=\"5944961\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong>\n<ol>\n<li><a href=\"\/en\/sa\/products\/hikvision-ds-k2801-value-series-card-access-contoller\/\">Hikvision DS-K2801 product page<\/a>, AZEIDK<\/li>\n<li><a href=\"\/en\/sa\/products\/zkteco-x100-and-x101\/\">ZKTeco X100 \/ X101 product page<\/a>, AZEIDK<\/li>\n<li><a href=\"\/en\/sa\/solutions\/security-surveillance-systems\/\">Security and surveillance systems<\/a>, AZEIDK<\/li>\n<li><a href=\"https:\/\/www.csemag.com\/door-locking-requirements-in-nfpa-101\/\" rel=\"nofollow noopener\" target=\"_blank\">Door locking requirements in NFPA 101<\/a>, Consulting-Specifying Engineer<\/li>\n<\/ol><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Door access control system cost in Saudi Arabia: how the reader, electric lock, exit button, controller, software and fire alarm release shape the price.<\/p>\n","protected":false},"author":0,"featured_media":24568,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-24607","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24607","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=24607"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24607\/revisions"}],"predecessor-version":[{"id":24871,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/24607\/revisions\/24871"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/24568"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=24607"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=24607"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=24607"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=24607"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}