{"id":22154,"date":"2026-11-11T11:07:19","date_gmt":"2026-11-11T08:07:19","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-11T11:13:24","modified_gmt":"2026-11-11T08:13:24","slug":"modular-clean-agent-co2-extinguishers-sffeco-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/modular-clean-agent-co2-extinguishers-sffeco-saudi\/","title":{"rendered":"Automatic Ceiling Fire Extinguishers and CO2 Extinguishers for Electrical and Server Rooms: SFFECO SFM and CD"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"22154\" class=\"elementor elementor-22154 elementor-22153 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2144164 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"2144164\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bfe769d elementor-widget elementor-widget-text-editor\" data-id=\"bfe769d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">An <strong>automatic ceiling fire extinguisher<\/strong> with clean agent is a cylinder hung from the ceiling of a small room. It discharges HFC-227ea (FM-200) or FK-5-1-12 on its own when heat breaks the glass bulb, or on a signal from an extinguishing control panel. It suits small electrical and server rooms, while a portable CO2 extinguisher remains the tool for early manual attack.<\/p>\n<p>This article covers SFFECO&#8217;s ceiling-mounted modular units SFM6 to SFM45 and SFFECO&#8217;s portable CO2 extinguishers (CD series), using the figures in the manufacturer&#8217;s official datasheets. It shows how to read the room-volume table and when a fixed system is the better answer.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c62d67 elementor-widget elementor-widget-text-editor\" data-id=\"2c62d67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li><a href=\"\/en\/sa\/products\/sffeco-automatic-modular-clean-agent-extinguishers\/\">SFFECO SFM6 to SFM45 modular units<\/a> hold 6 to 45 kg of agent at 15 bar, in cylinders hydrostatically tested at 30 bar.<\/li><li>Release is by a 68 \u00b0C glass bulb as standard, with an optional 24 V DC electric actuator for panel release.<\/li><li>The datasheet gives a room-volume range per model at 7% HFC-227ea and 4.5% FK-5-1-12, based on the Class C concentration in a table of NFPA 2001 (2018 edition).<\/li><li><a href=\"\/en\/sa\/products\/sffeco-portable-co2-fire-extinguishers\/\">SFFECO portable CO2 extinguishers<\/a> come in 3, 5 and 6 kg (CD-G) and 2.27 and 4.54 kg (CD-L). The product page lists CD5G, CD6G and CD5L as SASO approved.<\/li><li>A ceiling unit does not replace portable extinguishers, nor an engineered fixed system when the room size or hazard exceeds what the unit covers.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88be453 elementor-widget elementor-widget-text-editor\" data-id=\"88be453\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is SFFECO&#8217;s automatic ceiling clean agent extinguisher?<\/h2>\n<p>SFFECO (Saudi Factory for Fire Equipment Co., with its factory and head office in Riyadh according to the datasheet) describes the SFM series as self-contained, standalone modular extinguishers. Each unit is a powder-coated carbon steel cylinder on a ceiling bracket, with a chrome-plated brass glass-bulb discharge nozzle, a pressure gauge and a safety valve.<\/p>\n<p>The principle is close to a sprinkler: the bulb breaks at a set temperature and the agent floods the room. The difference is that the agent is an electrically non-conductive gas that leaves no residue, which suits electrical and electronic equipment that water or powder would damage.<\/p>\n<p>These units differ from the dry powder automatic extinguisher covered in our <a href=\"\/en\/sa\/media-center\/automatic-ceiling-fire-extinguisher\/\">automatic ceiling fire extinguisher guide<\/a>: here the agent is a clean gas, and coverage depends on room volume in cubic metres, not floor area.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-287ce3e elementor-widget elementor-widget-text-editor\" data-id=\"287ce3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How does the SFFECO SFM work?<\/h2>\n<h3>Thermal release by glass bulb<\/h3>\n<p>The standard bulb rating is 68 \u00b0C, with 57, 79, 93 and 141 \u00b0C available on request. The rating should sit above the highest normal room temperature so the bulb does not break in normal conditions, while still responding to a fire.<\/p>\n<h3>Electric release from a control panel<\/h3>\n<p>An optional 24 V DC pyrotechnic actuator lets a fire extinguishing control panel discharge the unit when detectors signal a fire, before heat reaches the bulb. This ties the unit to the detection system and gives a faster response.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b6ecd9 elementor-widget elementor-widget-text-editor\" data-id=\"1b6ecd9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>SFM6 to SFM45 models and protected room volume<\/h2>\n<p>The figures below are from SFFECO&#8217;s official datasheet (VER 00-04\/26), available on the AZEIDK product page. Volumes are at 21 \u00b0C and at the standard Class C (energised electrical) concentration from table A.5.4.2.2(b) of NFPA 2001, 2018 edition, as stated by the manufacturer.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Model<\/th><th>Agent (kg)<\/th><th>Fill range (kg)<\/th><th>Room volume, HFC-227ea 7% (m\u00b3)<\/th><th>Room volume, FK-5-1-12 4.5% (m\u00b3)<\/th><th>Cylinder \u00d8 (mm)<\/th><\/tr><\/thead><tbody><tr><td>SFM6<\/td><td>6<\/td><td>2.5\u20136<\/td><td>4.56\u201310.95<\/td><td>3.83\u20139.19<\/td><td>280<\/td><\/tr><tr><td>SFM10<\/td><td>10<\/td><td>4\u201310<\/td><td>7.30\u201318.25<\/td><td>6.13\u201315.31<\/td><td>280<\/td><\/tr><tr><td>SFM15<\/td><td>15<\/td><td>6\u201315<\/td><td>10.95\u201327.38<\/td><td>9.19\u201322.97<\/td><td>280<\/td><\/tr><tr><td>SFM20<\/td><td>20<\/td><td>8\u201320<\/td><td>14.60\u201336.51<\/td><td>12.25\u201330.63<\/td><td>280<\/td><\/tr><tr><td>SFM25<\/td><td>25<\/td><td>10\u201325<\/td><td>18.25\u201345.64<\/td><td>15.31\u201338.28<\/td><td>370<\/td><\/tr><tr><td>SFM30<\/td><td>30<\/td><td>13\u201331<\/td><td>23.73\u201356.59<\/td><td>19.91\u201347.47<\/td><td>370<\/td><\/tr><tr><td>SFM35<\/td><td>35<\/td><td>15\u201336<\/td><td>27.38\u201365.72<\/td><td>22.97\u201355.13<\/td><td>370<\/td><\/tr><tr><td>SFM40<\/td><td>40<\/td><td>18\u201342<\/td><td>32.86\u201376.67<\/td><td>27.57\u201364.32<\/td><td>505<\/td><\/tr><tr><td>SFM45<\/td><td>45<\/td><td>20\u201347<\/td><td>36.51\u201385.80<\/td><td>30.63\u201371.98<\/td><td>505<\/td><\/tr><\/tbody><\/table><\/div>\n<p>All models operate at 15 bar. The manufacturer states a tolerance of 10 mm on cylinder height and 5 mm on diameter.<\/p>\n<h3>Reading the table: a worked example<\/h3>\n<p>The minimum and maximum volumes match the minimum and maximum fill of the cylinder. A 30 m\u00b3 electrical room (say 4 \u00d7 3 \u00d7 2.5 m) falls inside the SFM20 range with HFC-227ea (14.60\u201336.51 m\u00b3). With FK-5-1-12 it is close to the SFM20 maximum (30.63 m\u00b3), so the SFM25 gives more margin. This is only a table reading: the designer sets the final quantity after checking net volume, temperature, hazard class and openings. Class A or B hazards need different concentrations; the datasheet lists 8.7% HFC-227ea and 5.9% FK-5-1-12 for Class B.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2c9421 elementor-widget elementor-widget-text-editor\" data-id=\"f2c9421\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Automatic FM-200 extinguisher or FK-5-1-12?<\/h2>\n<p>The same unit is filled with either agent. Differences from the datasheet:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>HFC-227ea (FM-200)<\/th><th>FK-5-1-12<\/th><\/tr><\/thead><tbody><tr><td>Stored as<\/td><td>Liquefied compressed gas<\/td><td>Liquid<\/td><\/tr><tr><td>Boiling point<\/td><td>-16.4 \u00b0C<\/td><td>49 \u00b0C<\/td><\/tr><tr><td>Class A concentration<\/td><td>6.7%<\/td><td>4.5%<\/td><\/tr><tr><td>Class B concentration<\/td><td>8.7%<\/td><td>5.9%<\/td><\/tr><tr><td>Class C concentration<\/td><td>7%<\/td><td>4.5%<\/td><\/tr><tr><td>SFM45 room volume<\/td><td>36.51\u201385.80 m\u00b3<\/td><td>30.63\u201371.98 m\u00b3<\/td><\/tr><\/tbody><\/table><\/div>\n<p>For the same agent weight, HFC-227ea covers a larger volume in this table. The choice usually follows the project specification, agent and refill availability, and environmental considerations. For both agents in fixed systems, see our <a href=\"\/en\/sa\/media-center\/nfpa-2001-clean-agent-standard-guide\/\">NFPA 2001 guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d41bb8f elementor-widget elementor-widget-text-editor\" data-id=\"d41bb8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>SFFECO CO2 extinguishers: CD models for electrical panels<\/h2>\n<p>SFFECO portable carbon dioxide extinguishers are designed for flammable liquid and gas fires and fires on electrical installations. Cylinders are weld-free, extruded from chrome molybdenum, manganese or carbon steel, with a 250 bar test pressure, electrostatic polyester powder coating and a storage range of -20 to +60 \u00b0C.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Model<\/th><th>Capacity<\/th><th>Total weight<\/th><th>Hose<\/th><th>Discharge (s)<\/th><th>SASO<\/th><\/tr><\/thead><tbody><tr><td>CD 3-G<\/td><td>3 kg<\/td><td>10.5 kg<\/td><td>Horn only<\/td><td>9\u201311<\/td><td>Not stated<\/td><\/tr><tr><td>CD 5-G<\/td><td>5 kg<\/td><td>16.3 kg<\/td><td>1220 mm<\/td><td>9\u201311<\/td><td>Approved<\/td><\/tr><tr><td>CD 6-G<\/td><td>6 kg<\/td><td>18.7 kg<\/td><td>1220 mm<\/td><td>9\u201311<\/td><td>Approved<\/td><\/tr><tr><td>CD 5-L<\/td><td>2.27 kg<\/td><td>8.45 kg<\/td><td>Horn only<\/td><td>7\u20139<\/td><td>Approved<\/td><\/tr><tr><td>CD 10-L<\/td><td>4.54 kg<\/td><td>15.35 kg<\/td><td>1220 mm<\/td><td>9\u201311<\/td><td>Not stated<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Maximum effective range is 5 m on every model. The short discharge time means the user has to get close and aim at the base of the flame from the start. Note that SFFECO&#8217;s catalogue uses Class C for gas fires and lists electrical fires separately, whereas in NFPA 10 Class C means electrical fires, so take care when comparing catalogues.<\/p>\n<p>For CO2 risks in small rooms, cold burns and test intervals, see our <a href=\"\/en\/sa\/media-center\/co2-fire-extinguisher-guide\/\">CO2 fire extinguisher guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c54411 elementor-widget elementor-widget-text-editor\" data-id=\"5c54411\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Ceiling unit, CO2 extinguisher or fixed system?<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Option<\/th><th>Operation<\/th><th>Suits<\/th><th>Limits<\/th><\/tr><\/thead><tbody><tr><td>SFFECO SFM ceiling unit<\/td><td>Automatic, by bulb or panel<\/td><td>Small enclosed electrical or server rooms, paint spray booths, flammable liquid stores, engine compartments<\/td><td>Fixed volume range per model; needs a reasonably tight room<\/td><\/tr><tr><td>SFFECO CO2 portable<\/td><td>Manual, needs a person present<\/td><td>Early fires in electrical panels or flammable liquids<\/td><td>5 m range, discharge in seconds, no protection when unattended<\/td><\/tr><tr><td>Fixed clean agent system such as <a href=\"\/en\/sa\/products\/sffeco-1230-clean-agent-fire-suppression-system\/\">SFFECO 1230<\/a><\/td><td>Cylinders, piping, nozzles and control panel<\/td><td>Larger data, control and archive rooms<\/td><td>Full engineering design and higher cost<\/td><\/tr><\/tbody><\/table><\/div>\n<p>As a rule, the ceiling unit protects the room when nobody is there, and the portable extinguisher gives people on site a chance to stop a fire early. When the room exceeds the largest model or is business-critical, consider a fixed system within our <a href=\"\/en\/sa\/solutions\/special-fire-suppression-systems\/\">special fire suppression systems<\/a>. For a portable clean agent option there are also <a href=\"\/en\/sa\/products\/standard-portable-fm-200-fire-extinguishers\/\">portable FM-200 extinguishers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16fda59 elementor-widget elementor-widget-text-editor\" data-id=\"16fda59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What to check before approving an automatic ceiling extinguisher in Saudi Arabia<\/h2>\n<ul><li><strong>Code and authority:<\/strong> the protection requirement comes from the SBC 801 Saudi Fire Protection Code, the project specification and Civil Defense approval. NFPA 2001 (clean agents) and NFPA 10 (portable extinguishers) are technical references the designer adopts, not automatically mandatory.<\/li><li><strong>Product conformity:<\/strong> the SASO Technical Regulation for Fire Control Materials and Equipment requires a certificate of conformity for extinguishing equipment through the SABER platform. The product page lists SASO approval only for CD5G, CD6G and CD5L; for other models and the ceiling units, request the conformity document for each model before supply.<\/li><li><strong>Net room volume:<\/strong> deduct fixed solid objects and compare with the model range.<\/li><li><strong>Room integrity:<\/strong> unsealed openings and open false ceilings reduce the concentration. See our <a href=\"\/en\/sa\/media-center\/clean-agent-room-integrity-test\/\">room integrity test article<\/a>.<\/li><li><strong>Occupancy:<\/strong> NFPA 2001 limits agent concentration in normally occupied spaces, so check the concentration reached at the minimum room volume.<\/li><li><strong>Detection link:<\/strong> if you choose the electric actuator, specify the extinguishing panel, detectors and warning devices in the same package.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f5687a elementor-widget elementor-widget-text-editor\" data-id=\"3f5687a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes<\/h2>\n<ul><li>Sizing by floor area and ignoring room height.<\/li><li>Using Class C figures for a room with flammable liquids (Class B), which the datasheet shows needs a higher concentration.<\/li><li>Mounting the unit off-centre or behind an obstruction without checking the manufacturer&#8217;s instructions.<\/li><li>Relying on the ceiling unit with no portable extinguisher at the door.<\/li><li>Buying a CO2 extinguisher without checking that the exact model is among the SASO-approved ones.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac3615c elementor-widget elementor-widget-text-editor\" data-id=\"ac3615c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>SFFECO supply from AZEIDK<\/h2>\n<p>AZEIDK supplies <a href=\"\/en\/brand\/sffeco\/\">SFFECO<\/a> SFM6 to SFM45 ceiling units and CD series CO2 extinguishers in Saudi Arabia, with technical selection, submittal preparation, installation, testing, commissioning and maintenance through its engineering team. The manufacturer datasheet can be downloaded from each product page, and other models are in our <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguishers category<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-867834b elementor-widget elementor-widget-text-editor\" data-id=\"867834b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>At what temperature does the SFFECO automatic ceiling extinguisher operate?<\/h3><\/summary><p>The standard bulb is 68 \u00b0C, with 57, 79, 93 or 141 \u00b0C on request. With the optional electric actuator, the panel can release it before heat reaches the bulb.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How many cubic metres does an SFM6 protect?<\/h3><\/summary><p>Per the datasheet, 4.56 to 10.95 m\u00b3 with HFC-227ea at 7%, and 3.83 to 9.19 m\u00b3 with FK-5-1-12 at 4.5%, for a Class C hazard at 21 \u00b0C.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the best extinguisher for a server room?<\/h3><\/summary><p>There is no single answer. For automatic protection of a small enclosed room, use a correctly sized clean agent ceiling unit plus a portable CO2 or clean agent extinguisher for manual use. Larger or critical rooms need an engineered fixed system.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are SFFECO CO2 extinguishers SASO approved?<\/h3><\/summary><p>The product page and datasheet state that CD5G, CD6G and CD5L are SASO approved. The source does not say so for CD 3-G and CD 10-L.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does an automatic ceiling extinguisher replace portable extinguishers?<\/h3><\/summary><p>No. The ceiling unit protects a set volume when nobody is present; portable extinguishers are still needed for early attack, in the numbers and locations set by the design and the authority.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95d2b5b elementor-widget elementor-widget-text-editor\" data-id=\"95d2b5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Choosing an automatic ceiling extinguisher starts with room volume and hazard class, then the agent and release method, then the conformity document for each model. A portable CO2 extinguisher covers the people on site. When the room exceeds what the unit covers, a fixed system is the right answer.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a39396 elementor-widget elementor-widget-text-editor\" data-id=\"6a39396\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need the right SFFECO model for your room?<\/strong> Send us the room dimensions, the equipment inside and the project specification, and we will recommend the model and agent with the datasheet and approval documents. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4df9a8b elementor-widget elementor-widget-text-editor\" data-id=\"4df9a8b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>Sources:<\/strong> Clean Agent Modular Extinguishers Datasheet, VER 00-04\/26 (SFFECO), Fire Extinguishers Catalogue, VER 01-01\/26 (SFFECO), <a href=\"\/en\/sa\/products\/sffeco-automatic-modular-clean-agent-extinguishers\/\" rel=\"noopener\" target=\"_blank\">SFFECO SFM6\u2013SFM45 product page<\/a> (AZEIDK), <a href=\"\/en\/sa\/products\/sffeco-portable-co2-fire-extinguishers\/\" rel=\"noopener\" target=\"_blank\">SFFECO portable CO2 product page<\/a> (AZEIDK), <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-2001-standard-development\/2001\" rel=\"noopener\" target=\"_blank\">NFPA 2001: Standard on Clean Agent Fire Extinguishing Systems<\/a> (NFPA), <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-10-standard-development\/10\" rel=\"noopener\" target=\"_blank\">NFPA 10: Standard for Portable Fire Extinguishers<\/a> (NFPA)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Automatic ceiling fire extinguisher by SFFECO, SFM6\u2013SFM45: room volume per model, FM-200 or FK-5-1-12, and SASO-approved CD portable CO2 extinguishers.<\/p>\n","protected":false},"author":0,"featured_media":21885,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325],"tags":[],"azeidk_region":[223],"class_list":["post-22154","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/22154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=22154"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/22154\/revisions"}],"predecessor-version":[{"id":22565,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/22154\/revisions\/22565"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/21885"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=22154"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=22154"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=22154"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=22154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}