{"id":21422,"date":"2026-11-11T10:57:19","date_gmt":"2026-11-11T07:57:19","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-12T18:39:56","modified_gmt":"2026-11-12T15:39:56","slug":"wedding-halls-event-halls-salamah-fire-requirements","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/wedding-halls-event-halls-salamah-fire-requirements\/","title":{"rendered":"Wedding Hall, Event Hall and Istiraha Safety Requirements in Saudi Arabia: Alarm, Extinguishers, Emergency Lighting, Exits and Salamah Licensing"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"21422\" class=\"elementor elementor-21422 elementor-21421 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9241f7 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"f9241f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7882d47 elementor-widget elementor-widget-text-editor\" data-id=\"7882d47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Wedding hall requirements<\/strong> in Saudi Arabia, on the fire safety side, come down to five items: a fire alarm system, suitable extinguishers, emergency lighting and exit signs, enough outward-opening exits, and fire-resistant separation of the kitchen and stores. The municipal licence is not issued before Civil Defense approval, which is handled on the Salamah platform.<\/p>\n<p>This guide brings together what the published official documents say for wedding halls, event halls and istirahat, then explains the Salamah licensing steps and what is checked after opening. If you are preparing a licence file or closing inspection notes, this is what AZEIDK&#8217;s <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> service covers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5837fc9 elementor-widget elementor-widget-text-editor\" data-id=\"5837fc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>The Ministry of Municipalities and Housing requires Civil Defense approval before an event hall is licensed, and compliance with the Saudi Fire Code, SBC 801.<\/li><li>The ministry&#8217;s technical requirements for wedding halls call for emergency lighting units, illuminated exit signs, a fire detection and alarm network, and extinguishers that are easy to see and reach.<\/li><li>Under the wedding hall technical requirements, main entrance doors open outward, each entrance is at least 2 m wide, and entrances are kept away from the kitchen and electrical rooms and panels.<\/li><li>The kitchen, its annexes and storage rooms are separated from the men&#8217;s, women&#8217;s and dining halls by fire-resistant barriers.<\/li><li>A Salamah licence is valid for one year and can be renewed from one month before expiry. High-risk activities need a maintenance contract with an approved safety company.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c0aace elementor-widget elementor-widget-text-editor\" data-id=\"1c0aace\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which official documents set wedding hall and istiraha requirements?<\/h2>\n<p>No single document covers everything. A hall is governed by several sources, each read within its own scope:<\/p>\n<ul><li><strong>Ministry requirements:<\/strong> the ministry (formerly the Ministry of Municipal and Rural Affairs) published the &#8220;Technical Requirements for Establishing Wedding Halls&#8221;, covering site, planning, electrical, safety and operation. It has also published a newer document titled &#8220;Requirements for Event Halls (Wedding Palaces) and Istirahat&#8221; on its official website; check its current version before applying for the activity licence.<\/li><li><strong>Event and exhibition hall requirements:<\/strong> posted by the ministry for public consultation on the Istitlaa platform (page last updated 22 January 2025). The posted version requires Civil Defense approval before licensing, compliance with everything in SBC 801, and refer to SBC 201 for general requirements. On 28 November 2025, Okaz reported that the ministry had approved regulatory requirements for these halls, including Civil Defense approval, fire prevention and protection requirements, and CCTV cameras.<\/li><li><strong>Saudi Building Code:<\/strong> the 2024 edition has been mandatory since 30 June 2025, as our article on the <a href=\"\/en\/sa\/media-center\/saudi-building-code-sbc-801-fire-protection\/\">Saudi Fire Code SBC 801<\/a> explains. A hall is an assembly building, so the designer sets its systems from the occupancy classification and the actual occupant load.<\/li><li><strong>Civil Defense and Salamah:<\/strong> the authority that issues the licence, inspects, and accepts or rejects.<\/li><\/ul>\n<p>In practice, the municipal requirements give the minimum for the activity, the code sets the technical detail, and Civil Defense has the final word. Where an older document and the current code differ, apply the stricter one or whatever the authority requires. The governing references differ from one assembly building to another, as our guide to <a href=\"\/en\/sa\/media-center\/mosques-fire-safety-guide\/\">mosque fire safety<\/a> shows.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-746a28f elementor-widget elementor-widget-text-editor\" data-id=\"746a28f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Civil Defense requirements for wedding halls: what is needed inside the building?<\/h2>\n<p>The table summarises the safety clauses of the ministry&#8217;s &#8220;Technical Requirements for Establishing Wedding Halls&#8221;, with clause numbers as published in the version on the ministry&#8217;s former website:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>What the requirements say<\/th><th>Clause<\/th><\/tr><\/thead><tbody><tr><td>Alarm and sprinklers<\/td><td>Automatic fire alarm where the building area exceeds 2,000 m\u00b2; automatic sprinklers where it exceeds 5,000 m\u00b2<\/td><td>2-6-4<\/td><\/tr><tr><td>Detection and alarm<\/td><td>A fire detection and alarm network as part of the required electrical works<\/td><td>2-3-9<\/td><\/tr><tr><td>Extinguishers<\/td><td>Suitable extinguishers in places that are easy to reach and see<\/td><td>2-6-5<\/td><\/tr><tr><td>Emergency lighting<\/td><td>Emergency lighting units and illuminated signs showing emergency exits<\/td><td>2-3-9<\/td><\/tr><tr><td>Emergency exits<\/td><td>Exits where travel distance to a safe area exceeds 15 m, and along the hall walls<\/td><td>2-6-2, 2-6-3<\/td><\/tr><tr><td>Entrances<\/td><td>At least three main entrances, separate entrances for women and men, doors opening outward<\/td><td>2-1-8, 2-1-10<\/td><\/tr><tr><td>Fire separation<\/td><td>Halls separated from stores and other spaces by walls, floors and doors rated at least 60 minutes<\/td><td>2-6-6<\/td><\/tr><tr><td>Kitchen<\/td><td>Kitchen and annexes separated from other spaces by fire-resistant barriers<\/td><td>2-6-7<\/td><\/tr><tr><td>Evacuation plan<\/td><td>An evacuation plan displayed in prominent places<\/td><td>2-6-10<\/td><\/tr><\/tbody><\/table><\/div>\n<p>This document carries no issue date and uses the ministry&#8217;s former name. The ministry&#8217;s newer event hall and istiraha document may set different figures, so treat these as guidance: the designer checks them against the updated document the municipality asks for, SBC 801 and SBC 201, and applies the stricter value or whatever the authority requires.<\/p>\n<h3>Fire alarm in an event hall<\/h3>\n<p>A hall is a large gathering space, often used at night with low light and loud sound. Sounders must be heard above the event, and the sound system can be set to mute on alarm where the design calls for it. Floor area, number of halls and the kitchen decide the system: a conventional zoned panel for small halls, or an addressable <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm system<\/a> that identifies each detector in larger buildings. AZEIDK supplies Context Plus panels and detectors of both types.<\/p>\n<h3>Extinguishers: which type where?<\/h3>\n<p>The municipal requirements do not name a type; they refer to &#8220;the relevant technical requirements&#8221;. Placement follows the hazard in each space, with NFPA 10 as the usual technical reference:<\/p>\n<ul><li>Halls and corridors: ABC dry powder, such as the <a href=\"\/en\/sa\/products\/dry-powder-fire-extinguisher-6kg-falcon-gold\/\">Falcon Gold 6 kg dry powder extinguisher<\/a>.<\/li><li>Electrical rooms, panels and the standby generator: CO2 extinguishers.<\/li><li>Kitchen: a wet chemical (Class K) extinguisher near the cooking line, such as the FG 6 kg wet chemical extinguisher.<\/li><\/ul>\n<h3>Emergency lighting and exit signs<\/h3>\n<p>A power cut in a full hall confuses guests and slows evacuation. The requirements therefore call for emergency lighting units and illuminated exit signs, plus a standby generator for lighting and critical circuits. Duration, maintained versus non-maintained fittings and monthly and annual testing are covered in our article on <a href=\"\/en\/sa\/media-center\/emergency-lighting-exit-signs-saudi\/\">emergency lighting and exit signs<\/a>.<\/p>\n<h3>Exits and occupant capacity<\/h3>\n<p>The earlier version of the wedding hall technical requirements ties entrance width to attendance: no entrance under 2 m, plus 0.05 m for every ten people above a capacity of 300. Capacity is calculated from hall area: 1.65 m\u00b2 per man in the men&#8217;s hall, 1.80 m\u00b2 per woman in the women&#8217;s hall including the stage, and 0.80 m\u00b2 per person in the dining hall. Entrances stay away from hazards such as the kitchen and electrical rooms, escape routes are short and clear, and exit floors are non-slip. Confirm these figures in the updated document before fixing the design.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dd6373 elementor-widget elementor-widget-text-editor\" data-id=\"2dd6373\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Does a hall kitchen need a hood suppression system?<\/h2>\n<p>Many halls have a main kitchen for banquets; others only a service kitchen for drinks. The event and exhibition hall requirements say that where a main kitchen exists, the ministry&#8217;s kitchen and restaurant requirements apply. The highest hazard in the building is then cooking oil on the line under the hood.<\/p>\n<p>The usual protection is a <a href=\"\/en\/sa\/solutions\/kitchen-fire-suppression-systems\/\">kitchen fire suppression system<\/a> on the hood and duct, designed to NFPA 17A for wet chemical systems and NFPA 96 for commercial cooking ventilation, with automatic gas shut-off on discharge. Systems offered by AZEIDK include ANSUL R-102, Hood Safer, American Fire Control and Falcon Gold. The system does not replace fire-resistant separation of the kitchen (clause 2-6-7) or the gas tank rules (at least 3 m from neighbouring buildings, clause 2-7-1).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ede8c6 elementor-widget elementor-widget-text-editor\" data-id=\"5ede8c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What about istiraha requirements?<\/h2>\n<p>The ministry&#8217;s document groups event halls and istirahat under one title, but their size and use vary widely. An istiraha rented out for events with a large majlis and kitchen is not the same as a small family one. Practical rule: confirm the activity registered on the Balady licence first, then its path on Salamah, because the activity classification decides the documents and whether an inspection is needed. The basics stay the same: extinguishers matched to each hazard, a detection and alarm method set by the designer, a clear exit, and separation of gas and kitchen. For how Balady licensing links to safety requirements, see <a href=\"\/en\/sa\/media-center\/salamah-certificate-shops-balady\/\">safety requirements before licensing on Salamah and Balady<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52a061f elementor-widget elementor-widget-text-editor\" data-id=\"52a061f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Salamah licence steps for a wedding hall<\/h2>\n<p>The safety certificate is issued online through Salamah, the platform of the General Directorate of Civil Defense; see our <a href=\"\/en\/sa\/media-center\/salamah-certificate-civil-defense-guide\/\">Salamah certificate guide<\/a>. The usual path for an event hall:<\/p>\n<ol><li><strong>Identify the activity path<\/strong> through the platform&#8217;s investor journey service. Low and medium-risk activities are &#8220;direct&#8221; and need a safety equipment invoice or a technical report; high-risk activities are &#8220;indirect&#8221; and need an inspection. See <a href=\"\/en\/sa\/media-center\/salamah-instant-vs-non-instant-licence\/\">instant licences vs direct and indirect activities<\/a>.<\/li><li><strong>Prepare the building:<\/strong> install the alarm, extinguishers, emergency lighting, exit signs and kitchen system to the approved drawings.<\/li><li><strong>Contract an approved safety company:<\/strong> on the indirect path the owner receives an SMS verification code after preliminary approval and gives it to the company, which uploads maintenance contracts and installation certificates.<\/li><li><strong>Inspection:<\/strong> on the indirect path, Civil Defense inspects the site before issuing the licence.<\/li><li><strong>Issue and renewal:<\/strong> the licence is valid for one year from final approval, and renewal opens one month before expiry.<\/li><\/ol>\n<p>In August 2026 the Insurance Authority, with Civil Defense, announced third-party civil liability insurance for crowded places and high-risk activities as a Civil Defense licence requirement, applied in phases. Check on the platform whether it applies to your hall now.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ce947a elementor-widget elementor-widget-text-editor\" data-id=\"4ce947a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>After opening: maintenance contract and emergency plan<\/h2>\n<p>The first licence is the start of the obligation. The wedding hall requirements make the owner or investor fully responsible to the authorities for violations (clause 3-2), require an emergency plan with staff trained in evacuation, equipment use and first aid (clause 3-4), and require periodic maintenance of the building and all its systems (clause 3-6).<\/p>\n<p>At renewal, Civil Defense looks at the real condition of the systems, not the contract alone: detectors covered by decorations, extinguishers with broken seals, or an exit door chained during an event. The owner needs a <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive maintenance contract<\/a> with documented visits and reports. How the contract ties into renewal is covered in <a href=\"\/en\/sa\/media-center\/salamah-licence-renewal-maintenance-contract\/\">Salamah licence renewal and the maintenance contract<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a192cea elementor-widget elementor-widget-text-editor\" data-id=\"a192cea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes that delay an event hall licence<\/h2>\n<ul><li>Decorations, curtains or fabric covering detectors or exit signs, or blocking a side exit.<\/li><li>Emergency doors opening inward, or locked from outside to stop entry.<\/li><li>Extinguishers present but hidden behind stacked chairs or inside the store.<\/li><li>A banquet kitchen with no hood suppression system, or one that does not shut off the gas.<\/li><li>Alarm panel faults isolated instead of fixed, or no test records.<\/li><li>No evacuation plan on display, or one that no longer matches the halls after alterations.<\/li><\/ul>\n<p>For the full list of notes and how to respond, see <a href=\"\/en\/sa\/media-center\/civil-defense-inspection-notes-fix\/\">common Civil Defense inspection notes<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c947518 elementor-widget elementor-widget-text-editor\" data-id=\"c947518\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK supports your hall&#8217;s licence file<\/h2>\n<p>In Saudi Arabia, AZEIDK submits and follows up Civil Defense transactions on Salamah, prepares safety requirements for Balady requests, and closes inspection notes before resubmission. The work includes a requirements checklist, a gap report on alarm and suppression systems, an organised file of drawings and reports, and a prioritised remediation plan. We then supply and install the alarm panels, extinguishers and kitchen systems needed, and take on the periodic maintenance contract. Supply and installation are quoted separately, and the final licensing decision rests with the competent authority alone.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b0348e elementor-widget elementor-widget-text-editor\" data-id=\"4b0348e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What are the Civil Defense requirements for wedding halls?<\/h3><\/summary><p>Mainly a detection and alarm system, visible extinguishers, emergency lighting and illuminated exit signs, outward-opening exits, fire-resistant separation of kitchen and stores, and a displayed evacuation plan, all in line with SBC 801.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does an event hall need Civil Defense approval before the municipal licence?<\/h3><\/summary><p>Yes. The ministry&#8217;s event and exhibition hall requirements posted on Istitlaa state that Civil Defense approval must be obtained before the licence is issued, and Okaz reported on 28 November 2025 that the ministry had approved this condition.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When are automatic sprinklers required in a wedding hall?<\/h3><\/summary><p>The earlier version of the wedding hall technical requirements calls for them above 5,000 m\u00b2. The designer sets the current threshold from SBC 801 and the occupant load, and it may be lower.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How long is a Salamah licence valid for a wedding hall?<\/h3><\/summary><p>One year from final approval. Renewal opens one month before expiry through the facility&#8217;s Salamah account.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a maintenance contract enough to renew the licence?<\/h3><\/summary><p>No. It is a required document for high-risk activities, but the inspection checks the actual systems, visit records and closed notes.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cacfdce elementor-widget elementor-widget-text-editor\" data-id=\"cacfdce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Wedding hall requirements are not a one-off checklist. Start with the document the municipality asks for, have the designer match it to SBC 801, then complete the alarm, extinguishers, emergency lighting, exits and kitchen before applying on Salamah. After opening, keep exits clear, decorations away from detectors and the maintenance contract current, because that is what each renewal checks.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f4da3c elementor-widget elementor-widget-text-editor\" data-id=\"0f4da3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing a hall or istiraha for a Salamah licence or renewal?<\/strong> Send us the layout, hall areas, kitchen arrangement and any previous inspection notes, and we will send a gap report with what needs to be supplied and installed. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5c2f93 elementor-widget elementor-widget-text-editor\" data-id=\"a5c2f93\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.momra.gov.sa\/generalserv\/Specs\/spec0004-1.asp\" rel=\"noopener\" target=\"_blank\">Technical Requirements for Establishing Wedding Halls<\/a> (Ministry of Municipal and Rural Affairs, Deputyship for Technical Affairs); <a href=\"https:\/\/istitlaa.scbc.gov.sa\/ar\/Municipality\/momra\/hall\/Pages\/default.aspx\" rel=\"noopener\" target=\"_blank\">Requirements for Event and Exhibition Halls<\/a> (Ministry of Municipalities and Housing, Istitlaa platform); <a href=\"https:\/\/www.okaz.com.sa\/local\/na\/2224140\" rel=\"noopener\" target=\"_blank\">8 conditions for regulating event and exhibition halls<\/a> (Okaz, 28 November 2025); <a href=\"https:\/\/www.okaz.com.sa\/local\/na\/2261649\" rel=\"noopener\" target=\"_blank\">No licence for high-risk activities without insurance<\/a> (Okaz, 17 August 2026); <a href=\"https:\/\/salamah.998.gov.sa\/\" rel=\"noopener\" target=\"_blank\">Salamah platform<\/a> (General Directorate of Civil Defense)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Wedding hall requirements in Saudi Arabia: Civil Defense approval, fire alarm, extinguishers, emergency lighting, exits, kitchen and Salamah licence steps.<\/p>\n","protected":false},"author":0,"featured_media":21393,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,327],"tags":[],"azeidk_region":[223],"class_list":["post-21422","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-by-facility-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/21422","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=21422"}],"version-history":[{"count":3,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/21422\/revisions"}],"predecessor-version":[{"id":24330,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/21422\/revisions\/24330"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/21393"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=21422"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=21422"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=21422"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=21422"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}