{"id":21408,"date":"2026-11-11T11:12:21","date_gmt":"2026-11-11T08:12:21","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-11T11:27:21","modified_gmt":"2026-11-11T08:27:21","slug":"foam-monitors-tank-farms-loading-areas-sffeco","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/foam-monitors-tank-farms-loading-areas-sffeco\/","title":{"rendered":"Foam Monitors for Tank Farms, Loading Racks and Ports: Fixed or Portable, Manual or Automatic, and How They Connect to the Foam Tank and Pump"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"21408\" class=\"elementor elementor-21408 elementor-21407 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d081e8f e-con-full az-el-article e-flex e-con e-parent\" data-id=\"d081e8f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f0e11b4 elementor-widget elementor-widget-text-editor\" data-id=\"f0e11b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>foam monitor<\/strong> is a high-capacity discharge device that throws large volumes of foam solution onto a flammable liquid fire from a safe distance, at tank farms, loading racks and marine jetties. It can be fixed or portable, manual or automatic, and it never works alone: it is the last link in a chain that starts with the fire pump, the foam tank and the proportioner.<\/p>\n<p>In Saudi Arabia, AZEIDK supplies <a href=\"\/en\/sa\/products\/sffeco-foam-monitors\/\">SFFECO foam monitors<\/a> together with foam bladder tanks, proportioners and Safe Guard AFFF concentrate. This guide covers when to choose a fixed or portable monitor, manual or automatic operation, how the flow calculation is built and how the monitor fits into the rest of the system.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cd40e1 elementor-widget elementor-widget-text-editor\" data-id=\"0cd40e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>Foam monitors protect large open areas: tank farms, loading racks, refineries, marine jetties and industrial yards.<\/li><li>AZEIDK&#8217;s product page lists SFFECO monitors at up to 50,000 L\/min, fixed or portable, manual or automatic, with an adjustable nozzle.<\/li><li>Monitor flow is the application rate multiplied by the protected area. The rate and discharge time come from NFPA 11 for the liquid and the application method.<\/li><li>A monitor needs correctly proportioned solution: pump, foam bladder tank, ratio controller, then the monitor.<\/li><li>The proportioner setting must match the concentrate in the tank, for example 3% or 6% AFFF.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99c0c80 elementor-widget elementor-widget-text-editor\" data-id=\"99c0c80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is a foam monitor and how does it work?<\/h2>\n<p>A monitor is a large discharge device that rotates horizontally and elevates vertically, carrying a nozzle that throws foam solution or water in a long-range stream. Compared with a foam handline, it delivers far more flow and reach. A handline suits a small fire close by. A monitor covers a tank surface, a spill bund or a full loading bay while keeping the operator away from the heat.<\/p>\n<p>In a fixed system the monitor receives ready-mixed foam solution (water plus concentrate at a set ratio) through the piping and valves. As the solution leaves the nozzle it entrains air and forms foam, which blankets the fuel, cuts off oxygen and suppresses vapour. The same monitor can discharge plain water to cool neighbouring tank shells.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2578466 elementor-widget elementor-widget-text-editor\" data-id=\"2578466\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>SFFECO foam monitors from AZEIDK: what the product page states<\/h2>\n<p>The data below comes from the <a href=\"\/en\/sa\/products\/sffeco-foam-monitors\/\">SFFECO foam monitors page<\/a> on the AZEIDK site and from SFFECO&#8217;s official product page at sffecoglobal.com. We add no figures that these sources do not give.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>What the sources state<\/th><\/tr><\/thead><tbody><tr><td>Product<\/td><td>SFFECO foam and water monitors<\/td><\/tr><tr><td>Maximum flow<\/td><td>Up to 50,000 L\/min (depending on size and model)<\/td><\/tr><tr><td>Mounting<\/td><td>Fixed or portable<\/td><\/tr><tr><td>Operation<\/td><td>Manual or automatic<\/td><\/tr><tr><td>Discharge pattern<\/td><td>Adjustable nozzle: beam, jet or straight flow<\/td><\/tr><tr><td>Listing<\/td><td>SFFECO&#8217;s official page states the monitors are UL listed. Check the exact model and size in the official UL directory<\/td><\/tr><tr><td>Listed applications<\/td><td>Fuel storage tanks and loading areas, refineries and petroleum sites, ports and aircraft hangars, large industrial yards<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Neither page gives operating pressure, inlet size, rotation angles or body material. Request these on the datasheet and catalogue for the selected model before the submittal goes to the consultant.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ced2e8 elementor-widget elementor-widget-text-editor\" data-id=\"5ced2e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where are foam monitors used on Saudi projects?<\/h2>\n<ul><li><strong>Tank farms:<\/strong> to cover a burning tank surface or the bund around it, and to cool adjacent tanks with water.<\/li><li><strong>Truck and rail loading racks:<\/strong> where spills happen during filling and the monitor covers the bay from outside it.<\/li><li><strong>Refineries, process units and petroleum sites:<\/strong> open areas and equipment that hoses cannot reach easily.<\/li><li><strong>Ports and marine jetties:<\/strong> at fuel and petroleum product transfer points.<\/li><li><strong>Aircraft hangars:<\/strong> among the applications listed on the AZEIDK product page.<\/li><li><strong>Large industrial yards:<\/strong> outdoor drum and flammable material storage.<\/li><\/ul>\n<p>Small fuel stations follow their own requirements for extinguishers and foam equipment, covered in <a href=\"\/en\/sa\/media-center\/fuel-station-fire-safety-requirements\/\">Fuel Station Safety Requirements in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31a5f74 elementor-widget elementor-widget-text-editor\" data-id=\"31a5f74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fixed or portable foam monitor?<\/h2>\n<p>A fixed monitor sits on a base or tower connected to the foam network and is ready at all times. A portable monitor is carried or wheeled to the fire and fed by hoses from a hydrant or a fire truck.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Criterion<\/th><th>Fixed monitor<\/th><th>Portable monitor<\/th><\/tr><\/thead><tbody><tr><td>Response<\/td><td>Immediate once the valve opens<\/td><td>Needs moving and hose connection<\/td><\/tr><tr><td>Coverage<\/td><td>Area defined in the design<\/td><td>Flexible, moved to suit the fire and wind<\/td><\/tr><tr><td>Supply<\/td><td>Fixed piping from the proportioner<\/td><td>Hoses from a hydrant or mobile source<\/td><\/tr><tr><td>Typical use<\/td><td>Permanent protection of tanks, loading racks and jetties<\/td><td>Back-up to fixed protection; several locations with few units<\/td><\/tr><tr><td>Site needs<\/td><td>Fixed base and protected pipe route<\/td><td>Access roads and room to lay hoses<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Many facilities combine both: fixed monitors for the highest-risk areas and portable units to back them up and reach unexpected points.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4f1770 elementor-widget elementor-widget-text-editor\" data-id=\"a4f1770\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Manual or automatic foam monitor?<\/h2>\n<p>With a manual monitor the operator aims the nozzle by handle or handwheel, so a trained person must stand at the monitor during the fire. This suits sites with a round-the-clock fire team or security crew and distances that allow safe standing.<\/p>\n<p>An automatic monitor is moved without anyone at the unit, keeping people away from heat and smoke. Control details differ between models, so they are taken from the SFFECO catalogue for the chosen model. Where flame detectors are installed, alarm signals can be tied into the operating logic as the designer specifies; see <a href=\"\/en\/sa\/media-center\/flame-detectors-industrial\/\">Flame Detectors in Industrial Facilities<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31fbe2c elementor-widget elementor-widget-text-editor\" data-id=\"31fbe2c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Beam, jet and straight flow: what the patterns mean<\/h2>\n<p>The SFFECO nozzle can be adjusted. A straight or jet stream gives the longest reach, used to hit a distant tank surface or clear a bund wall. A wider beam covers a closer, broader area and helps cool surfaces and shield people. In practice, foam is aimed at a wall or surface so it runs gently onto the fuel, not plunged into the burning liquid, which would splash fuel and break the blanket.<\/p>\n<p>Real reach depends on wind and on solution pressure at the inlet. Check the datasheet throw against site conditions and place monitors so each target can be reached from more than one direction.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-037a104 elementor-widget elementor-widget-text-editor\" data-id=\"037a104\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How is foam monitor flow calculated under NFPA 11?<\/h2>\n<p>The usual technical reference is NFPA 11, Standard for Low-, Medium-, and High-Expansion Foam, currently in its 2024 edition. The designer adopts it alongside Civil Defense requirements and the owner&#8217;s specifications. The calculation follows fixed steps:<\/p>\n<ol><li><strong>Define the protected area:<\/strong> the liquid surface in the tank, the bund area or the loading bay.<\/li><li><strong>Select the application rate and discharge time:<\/strong> from the NFPA 11 tables for the liquid (hydrocarbon or polar solvent) and the method (monitor, fixed tank outlets or handlines), checked against the concentrate&#8217;s listing data.<\/li><li><strong>Calculate solution flow:<\/strong> solution flow = application rate x protected area. Choose the number and size of monitors so actual flow covers this figure, with an allowance for wind losses.<\/li><li><strong>Calculate concentrate:<\/strong> concentrate = solution flow x proportioning ratio (3% or 6%) x discharge time, plus any supplementary foam hose streams.<\/li><li><strong>Calculate water:<\/strong> the water for the solution plus cooling water sets the fire pump flow and the water supply.<\/li><\/ol>\n<p>Monitors are not an automatic substitute for fixed outlets mounted on the tank itself. Whether they serve as primary or supplementary protection is a design decision, made by checking the NFPA 11 application-method provisions for the tank type, roof and diameter. Settle the primary protection method during <a href=\"\/en\/sa\/services\/engineering-design-calculations\/\">engineering design and calculations<\/a> before choosing the monitor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2874f1 elementor-widget elementor-widget-text-editor\" data-id=\"c2874f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How does the monitor connect to the foam tank, proportioner and pump?<\/h2>\n<p>Foam quality at the nozzle depends on every link upstream. The usual sequence in a fixed system:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Link<\/th><th>Role<\/th><th>Available from AZEIDK<\/th><\/tr><\/thead><tbody><tr><td>Fire pump<\/td><td>Delivers the flow and pressure for solution and cooling<\/td><td><a href=\"\/en\/sa\/products\/?product_category=fire-pumps\">Fire pumps<\/a><\/td><\/tr><tr><td>Foam bladder tank<\/td><td>Stores concentrate in a bladder and pushes it to the proportioner using water pressure<\/td><td><a href=\"\/en\/sa\/products\/sffeco-foam-bladder-tank\/\">SFFECO foam bladder tank<\/a> or WATEX UL-listed tanks<\/td><\/tr><tr><td>Ratio controller<\/td><td>Meters concentrate into the water stream across a range of flows and pressures<\/td><td><a href=\"\/en\/sa\/products\/sffeco-ratio-controller-proportioner\/\">SFFECO ratio controller<\/a><\/td><\/tr><tr><td>Foam concentrate<\/td><td>Forms foam once mixed with water<\/td><td><a href=\"\/en\/sa\/products\/safe-guard-3-aqueous-film-forming-foam-200-l\/\">Safe Guard 3% AFFF<\/a> or 6%<\/td><\/tr><tr><td>Foam monitor<\/td><td>Throws the solution and forms foam on the target<\/td><td>SFFECO foam monitors<\/td><\/tr><\/tbody><\/table><\/div>\n<p>How bladder tanks and proportioners work is explained in <a href=\"\/en\/sa\/media-center\/foam-proportioning-bladder-tank\/\">Foam Proportioning with Bladder Tanks<\/a>, and WATEX capacities in <a href=\"\/en\/sa\/media-center\/watex-foam-bladder-tanks-ul-saudi\/\">WATEX UL-Listed Foam Bladder Tanks<\/a>. For choosing the concentrate and its percentage, see <a href=\"\/en\/sa\/media-center\/foam-concentrate-brands-saudi\/\">AFFF Foam Concentrate in Saudi Arabia<\/a>.<\/p>\n<p>Three compatibility checks before ordering: the proportioner range covers both the smallest monitor and the largest group of monitors running together; the proportioning ratio matches the concentrate in the tank; and the tank capacity covers the calculated discharge time.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74a2d9c elementor-widget elementor-widget-text-editor\" data-id=\"74a2d9c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What regulatory frame applies in Saudi Arabia?<\/h2>\n<p>Facility fire protection falls under the Saudi Fire Protection Code SBC 801, part of the Saudi Building Code, and approval by the General Directorate of Civil Defense through the Salamah safety licensing platform. Industrial and petroleum facilities may also fall under High Commission for Industrial Security requirements, covered in <a href=\"\/en\/sa\/media-center\/hcis-industrial-security-fire-protection-news-en\/\">HCIS Requirements: Fire Protection at Industrial Facilities<\/a>. NFPA 11 serves as the technical reference for calculations and details as the project adopts it.<\/p>\n<p>In practice, the consultant&#8217;s submittal review asks for the datasheet, catalogue and listing evidence for the exact model, together with flow and concentrate calculations and a monitor layout drawing.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcf3a10 elementor-widget elementor-widget-text-editor\" data-id=\"bcf3a10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes when selecting a foam monitor<\/h2>\n<ul><li>Picking the catalogue&#8217;s maximum flow without calculating area and application rate.<\/li><li>A proportioner that does not cover the monitors designed to run together, giving weak foam or wasted concentrate.<\/li><li>A fixed monitor placed inside the radiant heat zone, so nobody can reach it during a fire.<\/li><li>Ignoring prevailing wind and real throw when locating monitors.<\/li><li>Mixing concentrate percentages in one tank or using an incompatible concentrate; see <a href=\"\/en\/sa\/media-center\/afff-foam-concentrate-shelf-life-testing\/\">AFFF Foam Concentrate Shelf Life<\/a>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd5c75b elementor-widget elementor-widget-text-editor\" data-id=\"dd5c75b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the difference between a foam monitor and a foam hose?<\/h3><\/summary><p>A hose suits small, close fires and puts the operator near the flames. A monitor gives much higher flow and reach and covers a tank or loading bay from a safe distance.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What flow does an SFFECO foam monitor deliver?<\/h3><\/summary><p>The product page lists SFFECO monitors at up to 50,000 L\/min. Actual flow depends on model, size and inlet pressure and is taken from the datasheet.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can a foam monitor discharge water only?<\/h3><\/summary><p>Yes. These are foam and water monitors. Water is typically used to cool tank shells and nearby equipment, and foam to extinguish the liquid fire.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Do I need a foam tank with a foam monitor?<\/h3><\/summary><p>In a fixed system, yes. The monitor needs correctly proportioned solution, usually from a foam bladder tank and a proportioner sized for the monitor flow.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which is better: a fixed or a portable foam monitor?<\/h3><\/summary><p>Neither in every case. Fixed monitors respond immediately for a defined area; portable ones give flexibility. Many sites use both, as the design dictates.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf30108 elementor-widget elementor-widget-text-editor\" data-id=\"bf30108\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Choose a foam monitor after calculating the protected area, application rate and discharge time, then decide fixed or portable and manual or automatic to suit the site and the people available. Its performance depends on the proportioner, tank, concentrate and pump, so select them together and review their documents in one submittal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11f8b11 elementor-widget elementor-widget-text-editor\" data-id=\"11f8b11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Planning protection for fuel tanks or a loading rack?<\/strong> Send us the areas, the liquid and the water source, and we will propose SFFECO monitors, a foam tank and a proportioner, with datasheets and catalogues. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15ec4db elementor-widget elementor-widget-text-editor\" data-id=\"15ec4db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/sffecoglobal.com\/sffeco-product\/foam-monitors\/\" rel=\"noopener\" target=\"_blank\">Foam Monitors<\/a> (SFFECO Global), <a href=\"https:\/\/sffecoglobal.com\/sffeco-product\/ratio-controller-proportioner\/\" rel=\"noopener\" target=\"_blank\">Ratio Controller \u2013 Proportioner<\/a> (SFFECO Global), <a href=\"https:\/\/sffecoglobal.com\/sffeco-product\/certified-foam-bladder-tank\/\" rel=\"noopener\" target=\"_blank\">Certified Foam Bladder Tank<\/a> (SFFECO Global), <a href=\"https:\/\/webstore.ansi.org\/standards\/nfpa\/nfpa112024\" rel=\"noopener\" target=\"_blank\">NFPA 11-2024, Standard for Low-, Medium-, and High-Expansion Foam<\/a> (NFPA via ANSI Webstore)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Foam monitor guide for tank farms, loading racks and ports: SFFECO monitors up to 50,000 L\/min, fixed or portable, manual or automatic, NFPA 11 flow sizing.<\/p>\n","protected":false},"author":0,"featured_media":21385,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,327],"tags":[],"azeidk_region":[223],"class_list":["post-21408","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-by-facility-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/21408","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=21408"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/21408\/revisions"}],"predecessor-version":[{"id":22571,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/21408\/revisions\/22571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/21385"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=21408"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=21408"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=21408"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=21408"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}