{"id":19760,"date":"2026-11-08T08:45:40","date_gmt":"2026-11-08T05:45:40","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-11T22:18:41","modified_gmt":"2026-11-11T19:18:41","slug":"fire-pump-types-selection-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-pump-types-selection-saudi\/","title":{"rendered":"Fire Pump Types: Electric, Diesel and Jockey, End-Suction, Split-Case and Vertical Turbine, and NFPA 20 Basics"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"19760\" class=\"elementor elementor-19760 elementor-19759 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f81428a e-con-full az-el-article e-flex e-con e-parent\" data-id=\"f81428a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0015572 elementor-widget elementor-widget-text-editor\" data-id=\"0015572\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>fire pump<\/strong> raises water pressure and flow from the tank to the sprinklers and hose cabinets as the design requires. A typical pump set has a main electric or diesel pump, a small jockey pump that holds pressure, and a controller for each pump. The type is chosen from the required flow and pressure and the tank water level.<\/p>\n<p>This is a reference hub that brings fire pump types together in one place: electric vs diesel vs jockey, end-suction vs split-case vs vertical turbine, and the NFPA 20 basics a Saudi consultant reviews. Each part has a detailed article on the AZEIDK site, linked where relevant. For hydraulic calculations and approval steps, start with the <a href=\"\/en\/sa\/media-center\/fire-pumps-selection-design-approvals-guide\/\">Fire Pump Selection Guide for Projects in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d797ba0 elementor-widget elementor-widget-text-editor\" data-id=\"d797ba0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>A fire pump is selected by its duty point (flow and pressure) from the hydraulic calculation, not by motor power alone.<\/li><li>The driver is electric or diesel; the jockey pump does not fight fire, it maintains network pressure.<\/li><li>Pump construction (end-suction, split-case, vertical turbine) depends on flow and on the water level in the tank or well.<\/li><li>The usual technical reference is NFPA 20, in the edition set by SBC 801 and the authority having jurisdiction.<\/li><li>Verify the UL listing or FM approval of the exact model, and the SABER certificate of conformity.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e517dd2 elementor-widget elementor-widget-text-editor\" data-id=\"e517dd2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is a fire pump and why does the network need one?<\/h2>\n<p>A fire network needs a set flow at a set pressure at the most remote sprinkler or highest hose cabinet. In most buildings, mains or roof-tank pressure cannot deliver this, so fire pumps are installed in a dedicated room next to the ground tank to boost pressure when needed.<\/p>\n<p>The pump normally sits on standby. When a sprinkler or hose opens, network pressure drops, the controller senses it through a pressure switch and starts the pump automatically. That is why the pump, controller and valves matter together. <a href=\"\/en\/sa\/media-center\/nfpa-20-fire-pumps-standard-guide\/\">NFPA 20: The Essential Requirements for Fire Pumps in Facilities<\/a> covers pump room components and general requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efcf175 elementor-widget elementor-widget-text-editor\" data-id=\"efcf175\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What are the fire pump types by driver: electric, diesel or jockey?<\/h2>\n<h3>Electric fire pump<\/h3>\n<p>Driven by an electric motor with a controller listed for fire pump service. It is simple to operate and maintain but depends entirely on the power supply, so the consultant asks how reliable that supply is: a single source, or an alternate source or generator?<\/p>\n<h3>Diesel fire pump<\/h3>\n<p>Driven by a diesel engine independent of mains power, with a fuel tank, starting batteries and its own controller. It is often the standby pump beside an electric pump, or the main pump where reliable power is not available. It needs a weekly run and engine checks. See <a href=\"\/en\/sa\/media-center\/electric-vs-diesel-fire-pumps\/\">Electric vs Diesel Fire Pumps: Comparison and Selection Criteria<\/a>.<\/p>\n<h3>Jockey pump<\/h3>\n<p>A small pump that makes up minor leakage and keeps the network pressurised so the main pump does not start on every small drop. It is not a firefighting pump. Its start and stop pressures sit above the main pump&#8217;s start pressure. Details: <a href=\"\/en\/sa\/media-center\/jockey-pump-sizing-pressure-settings\/\">Jockey Pumps: Sizing and Start\/Stop Pressure Settings<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b74a37b elementor-widget elementor-widget-text-editor\" data-id=\"b74a37b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is the difference between end-suction, split-case and vertical turbine pumps?<\/h2>\n<p>Construction is independent of the driver: a split-case pump, for example, can be electric or diesel.<\/p>\n<div class=\"az-table\"><table><thead><tr><th>Type<\/th><th>Concept<\/th><th>Typically chosen for<\/th><th>Approval note<\/th><\/tr><\/thead><tbody>\n<tr><td>End-suction<\/td><td>Suction at the end, discharge at the top, compact design<\/td><td>Small and medium projects with lower flows<\/td><td>Needs water reaching the suction under positive pressure<\/td><\/tr>\n<tr><td>Horizontal split-case<\/td><td>Horizontally split casing, double-suction impeller<\/td><td>Medium and large flows, major projects<\/td><td>Serviceable without removing piping; needs more room space<\/td><\/tr>\n<tr><td>Vertical turbine<\/td><td>Impellers submerged, driver above the tank or well<\/td><td>Water level below the pump: wells, deep tanks<\/td><td>Submergence and minimum water level checked carefully<\/td><\/tr>\n<tr><td>Vertical in-line<\/td><td>Pump and motor on a vertical axis in the pipe line<\/td><td>Tight spaces and limited flows<\/td><td>Confirm a listed model exists at the required flow<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Construction follows the duty point and how water reaches the suction. Where the ground-tank water level is below the pump centreline, a vertical turbine pump is the case to review. <a href=\"\/en\/sa\/media-center\/jack-pump-fire-pump-types\/\">Jack Pump Fire Pump Types: End-Suction, Split Case and Vertical Turbine<\/a> covers the three main types in more depth.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49b577d elementor-widget elementor-widget-text-editor\" data-id=\"49b577d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How do electric, diesel and jockey pumps work together in the pump room?<\/h2>\n<p>Many Saudi projects use what the market calls a fire pump set: a main electric pump, a diesel standby pump of equal performance, a jockey pump, and a controller for each. This is a common arrangement, not a fixed rule; the design may use a single pump or diesel pumps only, depending on system demand, power reliability and the authority&#8217;s requirements. For an example, see our guide to the 3PUMP <a href=\"\/en\/sa\/media-center\/3pump-fire-pump-packages-saudi\/\">fire pump package<\/a>, covering models from 500 to 1500 GPM, what Non-Listed means and when to ask for a UL\/FM version.<\/p>\n<div class=\"az-table\"><table><thead><tr><th>Element<\/th><th>Role<\/th><th>What is reviewed<\/th><\/tr><\/thead><tbody>\n<tr><td>Electric pump<\/td><td>Main pump on pressure drop<\/td><td>Supply reliability, listed controller, starting method<\/td><\/tr>\n<tr><td>Diesel pump<\/td><td>Standby or main, independent of power<\/td><td>Fuel tank, batteries, ventilation and exhaust, weekly run<\/td><\/tr>\n<tr><td>Jockey pump<\/td><td>Maintains pressure, makes up leakage<\/td><td>Start\/stop pressures, avoiding short cycling<\/td><\/tr>\n<tr><td>Controllers<\/td><td>Start each pump and signal the fire alarm panel<\/td><td>Listing, required signals, pressure sequence<\/td><\/tr>\n<tr><td>Test header and valves<\/td><td>Performance testing and isolation for maintenance<\/td><td>Supervised valves, flow meter or test header per design<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The pressure sequence sets which pump runs first: jockey, then electric, then diesel. Errors here later show up as short cycling or failure to start.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ead2482 elementor-widget elementor-widget-text-editor\" data-id=\"ead2482\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which NFPA 20 basics does the consultant check on a fire pump?<\/h2>\n<p>NFPA 20 is the US standard for installing stationary fire pumps and is used as a technical reference in Saudi projects, in the edition set by SBC 801 and the authority. A summary is no substitute for the standard, but these are the points usually raised, stated approximately:<\/p>\n<ul><li><strong>Listing:<\/strong> the pump and controller are models listed or approved for fire service (UL Listed or FM Approved), checked for the exact model, size and speed.<\/li><li><strong>Performance curve:<\/strong> the standard limits pressure at zero flow (churn) and at 150% of rated flow. Our Jack Pump page states churn between 101% and 140% of rated pressure, and at least 65% of rated pressure at 150% of rated flow.<\/li><li><strong>Suction:<\/strong> horizontal pumps are normally designed for positive suction; water below the pump is handled with suitable types such as vertical turbine.<\/li><li><strong>Pump room:<\/strong> fire-rated separation, drainage, ventilation and lighting, with specific provisions for the diesel engine and fuel.<\/li><li><strong>Testing:<\/strong> a factory test, then a field acceptance test comparing performance with the curve.<\/li><\/ul>\n<p>For periodic maintenance see <a href=\"\/en\/sa\/media-center\/electric-fire-pump-maintenance-checklist\/\">Electric Fire Pump Maintenance: Weekly, Monthly and Annual Checks<\/a> and <a href=\"\/en\/sa\/media-center\/diesel-fire-pump-engine-maintenance\/\">Diesel Fire Pump Engine Maintenance<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-843d66d elementor-widget elementor-widget-text-editor\" data-id=\"843d66d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which documents are needed to approve a fire pump in Saudi Arabia?<\/h2>\n<ol><li>Datasheet and performance curve showing the duty point.<\/li><li>Evidence of the model&#8217;s UL listing or FM approval where specified.<\/li><li>Motor or engine and controller datasheets.<\/li><li>Hydraulic calculation and suction check at minimum tank level.<\/li><li>Pump room drawings.<\/li><li>SABER certificate of conformity, as the SASO technical regulation for fire control equipment covers fire pumps.<\/li><\/ol>\n<p>After installation comes the field acceptance test, then the file submitted for Civil Defense procedures.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2637cad elementor-widget elementor-widget-text-editor\" data-id=\"2637cad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which fire pumps does AZEIDK supply?<\/h2>\n<p>AZEIDK supplies <strong>Jack Pump<\/strong> in three series, each available with an electric motor or diesel engine, as stated on the <a href=\"\/en\/sa\/media-center\/jack-pump-brand-fire-pumps-saudi-arabia\/\">Jack Pump in Saudi Arabia<\/a> page:<\/p>\n<div class=\"az-table\"><table><thead><tr><th>Series<\/th><th>Type<\/th><th>Flow range (gpm)<\/th><th>Product page<\/th><\/tr><\/thead><tbody>\n<tr><td>VES<\/td><td>End-suction<\/td><td>50 to 1,000<\/td><td><a href=\"\/en\/sa\/products\/jack-pump-ul-listed-end-suction-fire-pump-ves-series\/\">VES end-suction pump<\/a><\/td><\/tr>\n<tr><td>MSC<\/td><td>Horizontal split-case<\/td><td>300 to 8,000<\/td><td><a href=\"\/en\/sa\/products\/jack-pump-ul-listed-split-case-fire-pump-msc-series\/\">MSC split-case pump<\/a><\/td><\/tr>\n<tr><td>VTP<\/td><td>Vertical turbine<\/td><td>50 to 5,000<\/td><td><a href=\"\/en\/sa\/products\/jack-pump-ul-listed-vertical-turbine-fire-pump-vtp-series\/\">VTP vertical turbine pump<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The brand page itself advises checking the listing record for the specific model offered and requesting FM approval where specified. These are series ranges; the model is chosen from the curve and duty point. To understand what drives the final cost and how to prepare a quotation request, see our article on <a href=\"\/en\/sa\/media-center\/fire-pump-price-factors-saudi\/\">fire pump price in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4aa301e elementor-widget elementor-widget-text-editor\" data-id=\"4aa301e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Evaluating the brand and the supply chain behind it<\/h2>\n<p>Two offers labeled &#8220;UL Listed&#8221; can differ widely in what stands behind them. Before shortlisting a brand, check:<\/p>\n<ul>\n<li>Range: listed models of the right type around your duty point, so a design change does not force a change of brand.<\/li>\n<li>Water source: a vertical turbine pump is the usual choice where the water level sits below the pump, as in many below-grade tanks, so check for a listed model of that type.<\/li>\n<li>Package responsibility: who assembles the pump, driver, controller and accessories, and who signs for the whole package in the submittal.<\/li>\n<li>Factory testing: a certified shop test curve for each serial number, the reference for the field acceptance test.<\/li>\n<li>Support: documents for the exact models, and a local engineer who answers comments, attends tests and diagnoses faults.<\/li>\n<\/ul>\n<p>Our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/ul-listed-vs-fm-approved\/\">submittal checklist for UL Listed and FM Approved equipment<\/a> covers how to record each item in the submittal register.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b93e9f elementor-widget elementor-widget-text-editor\" data-id=\"4b93e9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Service and spare parts: questions to ask<\/h2>\n<p>A fire pump runs only for short test runs yet should work on demand for decades. Ask each supplier:<\/p>\n<ol>\n<li>Who will attend the field acceptance test? NFPA 20 (2025 edition, Section 14.2.1 per the technical committee&#8217;s second draft) requires the pump and controller manufacturers and, when supplied, the engine and transfer switch manufacturers, or their factory-authorized representatives; see our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-pump-acceptance-testing-commissioning\/\">fire pump acceptance testing guide<\/a>.<\/li>\n<li>Who supports the annual flow test? Under the 2023 edition of NFPA 25, as Inspect Point summarizes it (2026 is now current; check the adopted edition), results are compared with the acceptance test curve and a pressure drop of more than 5% must be investigated; see our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/nfpa-25-itm-water-based-systems-guide\/\">NFPA 25 inspection, testing and maintenance guide<\/a>.<\/li>\n<li>Which wear parts should be stocked on site, and which will the supplier hold locally?<\/li>\n<li>Are replacement parts supplied by the manufacturer for the listed model, so repairs stay within the original design?<\/li>\n<li>What operator training and technician response are offered, and who holds the controller and engine service documents?<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34bdc15 elementor-widget elementor-widget-text-editor\" data-id=\"34bdc15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What are common mistakes when choosing a fire pump?<\/h2>\n<ul><li>Choosing by motor power or price before calculating the duty point.<\/li><li>Ignoring minimum tank water level in the suction check.<\/li><li>Comparing quotes for pumps with different flow, pressure and listing.<\/li><li>Setting jockey and main pump pressures without a clear sequence.<\/li><li>Accepting a controller not listed for fire service with a listed pump.<\/li><li>Neglecting the weekly diesel run after handover.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8caeb elementor-widget elementor-widget-text-editor\" data-id=\"3e8caeb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is a fire pump?<\/h3><\/summary><p>A dedicated pump that raises water pressure and flow from the tank to sprinklers and hose cabinets, starting automatically when network pressure drops.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does a jockey pump fight fire?<\/h3><\/summary><p>No. It maintains network pressure and makes up minor leakage; firefighting relies on the main pump.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Do I need a diesel pump if I have an electric pump?<\/h3><\/summary><p>It depends on power supply reliability, the design and the authority&#8217;s requirements. Many projects add a diesel standby pump.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When should I choose a vertical turbine pump?<\/h3><\/summary><p>Usually when the water level is below the pump, as with wells and deep tanks, after the consultant reviews suction conditions.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Must a fire pump be UL listed or FM approved?<\/h3><\/summary><p>The main pump is normally a model listed or approved for fire service; the specification states which. Verify the exact model in the issuer&#8217;s record.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23229a8 elementor-widget elementor-widget-text-editor\" data-id=\"23229a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>A fire pump is part of a system: an electric or diesel main pump, a jockey pump, controllers, valves and testing. Construction and driver follow the duty point, suction conditions and power reliability; listing and conformity are verified before supply.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-664c232 elementor-widget elementor-widget-text-editor\" data-id=\"664c232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need a fire pump for a new project or a replacement?<\/strong> Send the duty point or network drawings and AZEIDK&#8217;s team will review the suitable Jack Pump type and the approval documents required. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9dc7f0 elementor-widget elementor-widget-text-editor\" data-id=\"d9dc7f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>Sources:<\/strong> <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-20-standard-development\/20\" rel=\"noopener\" target=\"_blank\">NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection<\/a> (NFPA); Saudi Fire Protection Code SBC 801 (Saudi Building Code National Center); Technical Regulation for Fire Control Materials and Equipment (SASO); <a href=\"\/en\/sa\/media-center\/jack-pump-brand-fire-pumps-saudi-arabia\/\">Jack Pump in Saudi Arabia<\/a> (AZEIDK)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire pump guide: electric vs diesel vs jockey, end-suction vs split-case vs vertical turbine, NFPA 20 basics and approval documents in Saudi Arabia.<\/p>\n","protected":false},"author":0,"featured_media":21909,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323],"tags":[],"azeidk_region":[223],"class_list":["post-19760","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=19760"}],"version-history":[{"count":5,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19760\/revisions"}],"predecessor-version":[{"id":23672,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19760\/revisions\/23672"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/21909"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=19760"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=19760"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=19760"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=19760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}