{"id":19738,"date":"2026-11-08T08:12:40","date_gmt":"2026-11-08T05:12:40","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-10T16:30:49","modified_gmt":"2026-11-10T13:30:49","slug":"fire-alarm-brands-saudi-arabia","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-alarm-brands-saudi-arabia\/","title":{"rendered":"Fire Alarm Brands in KSA: Who Makes What and How to Verify Each Model&#8217;s Approval"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"19738\" class=\"elementor elementor-19738 elementor-19737 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e99b42 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"5e99b42\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dff4eea elementor-widget elementor-widget-text-editor\" data-id=\"dff4eea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Fire alarm brands in KSA<\/strong> include Advanced, Apollo, Context Plus, Edwards, GENT, Hochiki, Honeywell, Notifier, Siemens, Simplex and Zeta, all of which show traceable evidence of presence in the Saudi market. But a brand being on the market does not mean every model is approved. Approval belongs to a model number and is checked in the certifier&#8217;s register, not in a catalogue.<\/p>\n<p>This guide gives a neutral, alphabetical map of these brands and keeps a clear line between what the manufacturer claims about its approvals and what can actually be checked in a register. For brand selection criteria and lifecycle questions, see <a href=\"\/en\/sa\/media-center\/best-fire-protection-fire-alarm-brands-saudi-arabia\/\">Fire Protection and Fire Alarm Brands in Saudi Arabia: How to Choose<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03a44aa elementor-widget elementor-widget-text-editor\" data-id=\"03a44aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>The list is alphabetical, not a ranking, and includes only brands with evidence of Saudi market presence found on 6 November 2026.<\/li><li>Approvals shown are &#8220;according to the manufacturer&#8221; and must be checked per model in the certifier&#8217;s register.<\/li><li>A brand appearing on a contractor&#8217;s website or at an exhibition does not prove that party is its agent or authorized distributor.<\/li><li>With addressable systems, choosing a brand usually means choosing a communication protocol and who can program and maintain the system.<\/li><li>AZEIDK is the Context Plus agent in Saudi Arabia and appears as one option among others.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c325985 elementor-widget elementor-widget-text-editor\" data-id=\"c325985\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What do we mean by fire alarm brands?<\/h2>\n<p>A brand is the name under which a <strong>fire alarm control panel<\/strong>, detectors, manual call points, notification appliances and modules are sold. One company may own several brands, as Honeywell does with Notifier and GENT, and ownership can change: Edwards became part of Kidde Global Solutions after Lone Star Funds completed its acquisition of Carrier&#8217;s commercial and residential fire business in December 2024, according to the deal announcement.<\/p>\n<p>That is why a brand name alone is not enough in a specification. What actually goes into a <strong>fire alarm system<\/strong> is specific models, each with its own datasheet, approvals and limits. A well-known brand may still have a model that is not listed by the body your specification requires.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-388ff2e elementor-widget elementor-widget-text-editor\" data-id=\"388ff2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How did we check each brand&#8217;s presence in Saudi Arabia?<\/h2>\n<p>We used three types of evidence and went back to the source on 6 November 2026:<\/p>\n<ol><li><strong>Documented market activity:<\/strong> participation in Intersec Saudi Arabia, or a published case study of a project in the Kingdom on the manufacturer&#8217;s website.<\/li><li><strong>The brand named on the website of a Saudi company<\/strong> that supplies or installs fire alarm systems. This shows the brand is traded, but not the nature of the relationship with the manufacturer.<\/li><li><strong>A declared agency,<\/strong> such as AZEIDK&#8217;s agency for Context Plus.<\/li><\/ol>\n<p>We left out globally known brands for which we found no sufficient, traceable evidence of Saudi presence at the time of review. That does not mean they are absent, only that we could not confirm it, so other brands may also be traded.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31c7d68 elementor-widget elementor-widget-text-editor\" data-id=\"31c7d68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Table of fire alarm brands in KSA<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Brand<\/th><th>Owner or manufacturer<\/th><th>Main categories<\/th><th>Evidence of Saudi presence<\/th><th>Approvals according to the manufacturer<\/th><th>Register check status<\/th><\/tr><\/thead><tbody>\n<tr><td>Advanced<\/td><td>Advanced Electronics Ltd (UK)<\/td><td>Addressable panels such as MxPro 5<\/td><td>Exhibited at Intersec Saudi Arabia 2024<\/td><td>States a BSI Kitemark licence to EN 54 for MxPro 5<\/td><td>Not checked in the BSI register<\/td><\/tr>\n<tr><td>Apollo<\/td><td>Apollo Fire Detectors (UK)<\/td><td>Detectors and loop devices on XP95 and Discovery protocols<\/td><td>Available from suppliers in the Saudi market<\/td><td>Vary by model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<tr><td>Avenger<\/td><td>Not stated on the supplier\u2019s site<\/td><td>OASIS addressable panels (2\u201316 loops) and SUPREME-RS (1 or 2 loops), SUPREME XT releasing panel, XP95A detectors, isolator and monitor modules, eMATRIX and eVIEW annunciators<\/td><td>Available in the Saudi market through distributors: Falcon Power\u2019s addressable fire alarm page<\/td><td>Per the supplier\u2019s page: XP95A heat detector to UL 521<\/td><td>Register not checked<\/td><\/tr><tr><td>Context Plus<\/td><td>Context Plus Ltd, Stockport (England)<\/td><td>FirePlus addressable panels, conventional panels, detectors, call points, EP203 extinguishing panel<\/td><td>AZEIDK is the brand&#8217;s agent in Saudi Arabia<\/td><td>UL certificate to EN 54-2 and EN 54-4 for FirePlus panels from one to four loops; UL listing for Series 65A detectors<\/td><td>UL file numbers (S24127 and S24128) for Series 65A detectors published on AZEIDK&#8217;s brand page; re-check per model<\/td><\/tr>\n<tr><td>Edwards<\/td><td>Kidde Global Solutions<\/td><td>Panels and devices<\/td><td>Available from suppliers in the Saudi market<\/td><td>Vary by model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<tr><td>GENT<\/td><td>Honeywell (UK)<\/td><td>Panels and detectors<\/td><td>Available from suppliers in the Saudi market<\/td><td>Vary by model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<tr><td>Hochiki<\/td><td>Hochiki Corporation (Japan)<\/td><td>Panels, detectors, wireless detection<\/td><td>Exhibited at Intersec Saudi Arabia 2025<\/td><td>The company states devices tested to UL 268 7th edition requirements<\/td><td>Not checked in Product iQ<\/td><\/tr>\n<tr><td>Honeywell<\/td><td>Honeywell<\/td><td>Several fire brands including Notifier and GENT<\/td><td>A Saudi company states in the Intersec Saudi Arabia exhibitor directory that it is a Honeywell distributor<\/td><td>Vary by brand and model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<tr><td>Notifier<\/td><td>Honeywell<\/td><td>Panels and detectors<\/td><td>Available from suppliers in the Saudi market<\/td><td>Vary by model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<tr><td>Siemens (Cerberus PRO)<\/td><td>Siemens<\/td><td>Panels and detectors<\/td><td>Published case study for King Khalid University<\/td><td>Product page titled Cerberus PRO (UL), no listing number shown<\/td><td>Not checked in Product iQ<\/td><\/tr>\n<tr><td>Simplex<\/td><td>Johnson Controls<\/td><td>Fire alarm panels<\/td><td>Available from suppliers in the Saudi market<\/td><td>Vary by model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<tr><td>Zeta<\/td><td>Zeta Alarm Systems (UK)<\/td><td>Panels and detectors<\/td><td>Available from suppliers in the Saudi market<\/td><td>Vary by model<\/td><td>Not reviewed in this article<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The table is a starting point, not an approved list. It does not say one brand is better than another, that the companies naming a brand are its agents, or that every model is acceptable on your project.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df2115a elementor-widget elementor-widget-text-editor\" data-id=\"df2115a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is the difference between a manufacturer&#8217;s claim and a verified listing?<\/h2>\n<p>A manufacturer may write &#8220;UL Listed&#8221; or &#8220;EN 54 certified&#8221; in its catalogue. That is an important statement, but it remains a claim until you find the same model in the certifier&#8217;s register. The gap shows up in three common cases:<\/p>\n<ul><li><strong>Brand-level, not model-level approval:<\/strong> the company appears in the register, but the model offered to you is not among the listed models.<\/li><li><strong>Approval for part of a family:<\/strong> for example, a certificate covering one- to four-loop panels while the offer is a six-loop panel.<\/li><li><strong>A different standard:<\/strong> an EN 54 certificate where the specification asks for a UL listing, or the reverse.<\/li><\/ul>\n<p>See <a href=\"\/en\/sa\/media-center\/verify-ul-fm-lpcb-listing-steps\/\">How to Verify UL, FM and LPCB Approval Step by Step<\/a> for searching each register, and <a href=\"\/en\/sa\/media-center\/en54-fire-alarm-standard-guide\/\">EN 54 Fire Alarm Standard Guide<\/a> for the parts covering panels and detectors.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c0eca6 elementor-widget elementor-widget-text-editor\" data-id=\"0c0eca6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How do you verify a fire alarm panel or detector model?<\/h2>\n<ol><li><strong>Ask for the full model number<\/strong> in the offer, not just the family name.<\/li><li><strong>Open the datasheet<\/strong> and note the approvals stated for that model, with file or certificate number if given.<\/li><li><strong>Search the register:<\/strong> UL Product iQ for UL listings, FM Approval Guide for FM approvals, RedBookLive for LPCB, or the register of the body that issued the EN 54 certificate.<\/li><li><strong>Match the details:<\/strong> certificate holder, model number, standard and certificate status.<\/li><li><strong>Record the result<\/strong> in the submittal with the search date.<\/li><\/ol>\n<p>Note that fire alarm systems are excluded from the scope of the SASO Technical Regulation for Fire Control Materials and Equipment, under Article 2 of the regulation. Acceptance therefore rests on the design basis under the Saudi Fire Protection Code (SBC 801), the project requirements, the consultant and Civil Defense.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff981aa elementor-widget elementor-widget-text-editor\" data-id=\"ff981aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why is brand choice tied to programming and maintenance?<\/h2>\n<p>In an <strong>addressable<\/strong> system, the panel talks to detectors and modules over a communication protocol. Some brands use a protocol exclusive to their own devices, while some panels run on a protocol shared by several companies. Context Plus FirePlus panels, for example, run on Apollo&#8217;s XP95 and Discovery protocols according to the product page. In practice, loop devices must match the panel&#8217;s protocol, and whoever programs and repairs the system later needs that brand&#8217;s tools.<\/p>\n<p>In a <strong>conventional<\/strong> system compatibility is usually simpler, but checking the datasheet is still necessary. For a detailed comparison, see <a href=\"\/en\/sa\/media-center\/fire-alarm-systems-saudi-arabia\/\">Conventional and Addressable Fire Alarm Systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60d66b0 elementor-widget elementor-widget-text-editor\" data-id=\"60d66b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Questions to ask the supplier before approving a brand<\/h2>\n<ul><li>What is the full model number of each panel and detector, and the file or certificate number for each?<\/li><li>Are you an agent or authorized distributor of the manufacturer, with a valid authorization letter?<\/li><li>Who holds the programming tools and training for this panel in the Kingdom?<\/li><li>How long will spare parts be available, and is the model still in production?<\/li><li>Are the proposed detectors compatible with the panel&#8217;s protocol according to the datasheet?<\/li><\/ul>\n<p>To read and check an authorization letter, see <a href=\"\/en\/sa\/media-center\/verify-authorized-distributor-saudi\/\">How to Confirm a Fire Equipment Distributor Is Really Authorized in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-064cf72 elementor-widget elementor-widget-text-editor\" data-id=\"064cf72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes<\/h2>\n<ul><li>Writing a brand name in the specification without models or standards.<\/li><li>Treating a company&#8217;s presence in the UL register as proof that all its products are listed.<\/li><li>Mixing detectors on a different protocol on an addressable loop.<\/li><li>Accepting a certificate image in the submittal without checking its status in the register.<\/li><li>Ignoring who will program and maintain the system after handover.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9179afd elementor-widget elementor-widget-text-editor\" data-id=\"9179afd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Is this a ranking of the best fire alarm brands in KSA?<\/h3><\/summary><p>No. The list is alphabetical, includes no rating, and shows only brands with evidence of Saudi market presence.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are all products of a UL-listed brand approved?<\/h3><\/summary><p>No. Listings cover specific models. Search for the exact model in Product iQ before approval.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does Civil Defense require a specific alarm brand?<\/h3><\/summary><p>We found no requirement for a particular brand. The reference is the SBC 801 design basis, the project requirements and the approvals set in the specification.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can I install another brand&#8217;s detectors on my addressable panel?<\/h3><\/summary><p>Only if they are compatible with the panel&#8217;s protocol according to both manufacturers&#8217; datasheets and installation manuals; otherwise the panel may not recognise the device.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which fire alarm brand does AZEIDK represent?<\/h3><\/summary><p>AZEIDK is the Context Plus agent in Saudi Arabia, supplying addressable and conventional panels, detectors, call points, notification appliances and a gas extinguishing control panel.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea931d2 elementor-widget elementor-widget-text-editor\" data-id=\"ea931d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>There are many fire alarm brands in KSA, and the real difference on your project shows at model level: its actual listing in the register, protocol compatibility, and who can program and maintain it. Use the table to see what is traded, then verify each model before it enters the submittal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-838ad09 elementor-widget elementor-widget-text-editor\" data-id=\"838ad09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Comparing offers with different alarm brands?<\/strong> AZEIDK&#8217;s team can review the proposed models and their documents through our <a href=\"\/en\/sa\/services\/technical-selection-of-systems-equipment\/\">technical selection of systems and equipment<\/a> service, and supply Context Plus panels and devices from our branches in Jeddah, Riyadh, Dammam, Makkah, Taif, Jazan, Khamis Mushait and Buraydah, including Civil Defense and Salamah transactions. <a href=\"\/en\/sa\/contact\/\">Request a consultation or quotation<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b276550 elementor-widget elementor-widget-text-editor\" data-id=\"b276550\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-72-standard-development\/72\" rel=\"noopener\" target=\"_blank\">NFPA 72<\/a> (NFPA), <a href=\"https:\/\/productiq.ulprospector.com\" rel=\"noopener\" target=\"_blank\">UL Product iQ<\/a>, <a href=\"https:\/\/www.approvalguide.com\" rel=\"noopener\" target=\"_blank\">FM Approval Guide<\/a>, <a href=\"https:\/\/www.redbooklive.com\" rel=\"noopener\" target=\"_blank\">RedBookLive<\/a> (LPCB), <a href=\"https:\/\/www.businesswire.com\/news\/home\/20241202006511\/en\/Lone-Star-Completes-Acquisition-of-Carriers-Commercial-and-Residential-Fire-Business-Forming-Kidde-Global-Solutions\" rel=\"noopener\" target=\"_blank\">Lone Star acquisition announcement<\/a>, <a href=\"https:\/\/advancedco.com\/product\/advanced-mxpro-5\/mxpro-5-approvals\" rel=\"noopener\" target=\"_blank\">MxPro 5 approvals page<\/a> (Advanced), <a href=\"\/en\/sa\/media-center\/context-plus-brand-fire-alarm-saudi-arabia\/\">Context Plus in Saudi Arabia<\/a> (AZEIDK), and brands&#8217; official websites (reviewed 6 November 2026)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire alarm brands in KSA: a neutral table of traded brands with Saudi presence evidence, separating manufacturer approval claims from verified listings.<\/p>\n","protected":false},"author":0,"featured_media":22280,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[],"azeidk_region":[223],"class_list":["post-19738","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19738","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=19738"}],"version-history":[{"count":2,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19738\/revisions"}],"predecessor-version":[{"id":20268,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19738\/revisions\/20268"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/22280"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=19738"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=19738"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=19738"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=19738"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}