{"id":19316,"date":"2026-11-02T16:00:00","date_gmt":"2026-11-02T16:00:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-02T09:53:36","modified_gmt":"2026-11-02T09:53:36","slug":"fire-extinguisher-maintenance-refill","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-extinguisher-maintenance-refill\/","title":{"rendered":"Fire Extinguisher Maintenance and Recharging: Monthly, Annual and Hydrostatic Testing"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"19316\" class=\"elementor elementor-19316 elementor-19315 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a4f736 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"3a4f736\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8b1a12c elementor-widget elementor-widget-text-editor\" data-id=\"8b1a12c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">An extinguisher on the wall looks ready, but whether it works depends on the <strong>fire extinguisher maintenance<\/strong> programme behind it: a monthly check by facility staff, annual maintenance, and internal examination, recharging and hydrostatic testing when due, all recorded on tags and logs that can be shown at inspection.<\/p>\n<p>This article covers each service level, who performs it, what gets recorded and what a maintenance contract should include. AZEIDK provides fire extinguisher maintenance through its own maintenance team, as part of its <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance<\/a> service for fire protection and alarm systems, with the exact scope set by contract; this guide helps you define the extinguisher clauses in that contract. For selection and placement, see our <a href=\"\/en\/sa\/media-center\/nfpa-10-portable-fire-extinguishers-guide\/\">NFPA 10 guide to portable extinguishers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd86fc0 elementor-widget elementor-widget-text-editor\" data-id=\"fd86fc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>Monthly inspection, at intervals not exceeding 31 days, is done by trained staff; NFPA 10 does not require them to be certified.<\/li><li>Annual maintenance and recharging require a certified person; hydrostatic testing requires people trained and certified for it.<\/li><li>A rechargeable extinguisher is recharged after any use, however brief, and is replaced immediately with a suitable unit of at least equal rating while out for service.<\/li><li>Each service level leaves a mark: annual tag, six-year label, verification-of-service collar and hydrostatic test label.<\/li><li>SBC 801 and Civil Defense determine which NFPA 10 edition applies. A maintenance contract documents the work but does not shift responsibility from the owner.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-304de62 elementor-widget elementor-widget-text-editor\" data-id=\"304de62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire extinguisher maintenance levels: who does what?<\/h2>\n<p>NFPA 10 separates inspection, a quick check that the extinguisher is in place and ready, from maintenance, a full examination of the mechanical parts, agent and expelling means. It also sets periodic internal examination, recharging and hydrostatic testing.<\/p>\n<p>The intervals below have been stable across NFPA 10 editions, but always check the text of the edition your project adopts.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Level<\/th><th>Interval under NFPA 10<\/th><th>Performed by<\/th><th>Record left behind<\/th><\/tr><\/thead><tbody><tr><td>Monthly inspection<\/td><td>When first placed in service, then at intervals of no more than 31 days, or more often where site conditions require it<\/td><td>Trained facility staff (no certification required)<\/td><td>Date and the inspector&#8217;s name or initials, on a tag, checklist or electronic record<\/td><\/tr><tr><td>Annual maintenance<\/td><td>At intervals of no more than one year, at the time of hydrostatic testing, or when an inspection shows the need<\/td><td>Certified technician<\/td><td>Tag showing month and year, the technician and the service agency<\/td><\/tr><tr><td>Internal examination<\/td><td>Every 1 to 6 years depending on type; the extinguisher must be emptied<\/td><td>Certified technician<\/td><td>Internal examination label and verification-of-service collar<\/td><\/tr><tr><td>Recharging<\/td><td>After any use, or when inspection or servicing shows the need<\/td><td>Certified technician<\/td><td>Verification-of-service collar and an updated record<\/td><\/tr><tr><td>Hydrostatic test<\/td><td>Every 5 or 12 years depending on type and shell material<\/td><td>A person trained in pressure testing and certified, with suitable equipment<\/td><td>Test label or stamp on the cylinder<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b637bd elementor-widget elementor-widget-text-editor\" data-id=\"7b637bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The Saudi framework: what is mandatory and what is a reference<\/h2>\n<p>NFPA 10 is a technical reference. The edition that applies is set by the referenced standards in the Saudi Fire Protection Code (SBC 801) and by General Directorate of Civil Defense requirements; a new edition is not automatically mandatory, as our <a href=\"\/en\/sa\/media-center\/nfpa-10-2026-portable-extinguishers-news-en\/\">NFPA 10 2026 edition news<\/a> explains.<\/p>\n<p>For licensing, Elm&#8217;s overview of the Salamah platform states that high-risk activities must contract with a safety company and provide maintenance contracts before the Civil Defense inspection, while some low- and medium-risk activities are licensed on a safety tools invoice or technical report from firms approved on the platform.<\/p>\n<p>A replacement extinguisher falls under the SASO Technical Regulation for Fire Control Materials and Equipment, which requires a certificate of conformity for extinguishing equipment before it is placed on the market.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20c875b elementor-widget elementor-widget-text-editor\" data-id=\"20c875b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Annual maintenance: what the technician actually does<\/h2>\n<p>Annual maintenance follows the manufacturer&#8217;s service manual and typically includes:<\/p>\n<ul><li>all monthly inspection items: location, access, gauge reading, pull pin and tamper seal;<\/li><li>checking that the nameplate operating instructions are present and legible;<\/li><li>replacing any gauge that is broken, cracked, illegible, not working or contains water;<\/li><li>uncoiling and examining the hose on wheeled units;<\/li><li>the annual conductivity test on CO2 hose assemblies, replacing any hose that fails;<\/li><li>recording when the next internal examination and hydrostatic test are due.<\/li><\/ul>\n<p>A tag is then attached showing the month and year, the technician and the service agency. If a unit goes to the workshop, NFPA 10 requires immediate replacement with one suitable for the hazard and of at least equal rating.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1376ea elementor-widget elementor-widget-text-editor\" data-id=\"f1376ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Internal examination and six-year maintenance<\/h2>\n<p>An internal examination means emptying the extinguisher and examining the cylinder and parts inside. The NFPA 10 interval ranges from 1 year for cartridge-operated dry chemical, to 3 years for foam, 5 years for water, CO2 and wet chemical, and 6 years for stored-pressure dry chemical in mild steel, brazed brass or aluminium shells. The full table is in the NFPA 10 guide.<\/p>\n<p>Six-year maintenance is the most common case, because most installed units are stored-pressure dry chemical. Every six years, stored-pressure units requiring a 12-year hydrostatic test are emptied, examined inside and out, and labelled with the month and year, technician and agency.<\/p>\n<p>Non-rechargeable extinguishers are not internally examined; they are removed from service no later than 12 years after manufacture.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b05728 elementor-widget elementor-widget-text-editor\" data-id=\"8b05728\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Recharging fire extinguishers after use<\/h2>\n<p>NFPA 10 requires every rechargeable extinguisher to be recharged after any use, or when inspection or servicing shows the need. A service provider should:<\/p>\n<ol><li>use only the agent on the nameplate, or one proven to have the same chemical composition;<\/li><li>never mix multipurpose (ABC) with alkaline-based dry chemicals, which the standard prohibits;<\/li><li>pressurise dry chemical and halogenated units with standard industrial-grade nitrogen with a dew point no higher than \u221251\u00b0C (\u221260\u00b0F), since moisture causes powder to cake;<\/li><li>leak-test stored-pressure and self-expelling units, such as CO2, after recharging;<\/li><li>fit a verification-of-service collar after recharging or internal examination.<\/li><\/ol>\n<p>The collar is a ring around the cylinder neck that cannot be removed without taking the valve off, showing the month and year and the agency. It proves the extinguisher was actually opened. Cartridge- and cylinder-operated units are exempt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a162fc3 elementor-widget elementor-widget-text-editor\" data-id=\"a162fc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Hydrostatic testing and when a cylinder is condemned<\/h2>\n<p>A hydrostatic test confirms the cylinder can safely hold its working pressure. NFPA 10 requires it to be done by people trained in pressure-testing procedures and holding the required certification, with suitable equipment and facilities. The interval is 5 years for water, foam, CO2 and wet chemical units and 12 years for most stored-pressure dry chemical units; the full table by type is in our <a href=\"\/en\/sa\/media-center\/nfpa-10-portable-fire-extinguishers-guide\/\">NFPA 10 guide<\/a>.<\/p>\n<p>Some cylinders are not tested at all: the standard lists conditions under which a cylinder is condemned or destroyed by the owner, including exposure to excessive heat, flame or fire. A unit that has been in a fire should not return to service until a certified technician has decided whether its cylinder is serviceable.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e5bae1 elementor-widget elementor-widget-text-editor\" data-id=\"8e5bae1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Tags and records: the extinguisher file at inspection<\/h2>\n<p>Each service level leaves a mark on the extinguisher or in the records:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Mark<\/th><th>When it is added<\/th><th>What it shows<\/th><\/tr><\/thead><tbody><tr><td>Monthly inspection record<\/td><td>Every month<\/td><td>Date and inspector. Keep enough records to show that at least the last 12 monthly inspections were done<\/td><\/tr><tr><td>Annual maintenance tag<\/td><td>At each annual maintenance<\/td><td>Month and year, the technician and the agency<\/td><\/tr><tr><td>Six-year label<\/td><td>At the internal examination of stored-pressure units<\/td><td>Month and year, the technician, and the agency<\/td><\/tr><tr><td>Verification-of-service collar<\/td><td>After recharging or internal examination<\/td><td>Month and year, and the agency<\/td><\/tr><tr><td>Hydrostatic test label or stamp<\/td><td>After a passed test<\/td><td>Test date and who carried out the test<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Good practice is an inventory listing each extinguisher&#8217;s number, location, type, year of manufacture and next due dates, so units falling due in the same year are visible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2b9cd8 elementor-widget elementor-widget-text-editor\" data-id=\"a2b9cd8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What should an extinguisher maintenance contract cover?<\/h2>\n<p>Extinguisher maintenance sits within the wider fire system contract but needs its own clauses, because part of the work happens in a workshop. Before signing, check that it covers:<\/p>\n<ul><li>an inventory of covered extinguishers by number, type, size and location, plus a list of what is excluded;<\/li><li>who does the monthly inspection and who reviews the records, and who does the annual maintenance;<\/li><li>how extinguishers are taken to the workshop, and how replacement units of at least equal rating are provided while they are away;<\/li><li>separate prices for recharging after use, internal examinations and hydrostatic tests in the years they fall due, and replacement parts such as gauges and hoses;<\/li><li>technician qualifications, and who carries out the hydrostatic tests;<\/li><li>the report format and delivery date, and confirmation that the records belong to the owner and are handed over when the contract ends.<\/li><\/ul>\n<p>AZEIDK&#8217;s <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance<\/a> service provides an agreed visit schedule, checklists for each system, a report after every visit with findings and recommended corrective actions, and an up-to-date maintenance log for inspection or licence renewal. The contract states whether spare parts are included, and systems installed by others are covered after a site survey. For general contract clauses, see <a href=\"\/en\/sa\/media-center\/fire-systems-maintenance-contracts-saudi-arabia\/\">fire system maintenance contracts in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57e5a74 elementor-widget elementor-widget-text-editor\" data-id=\"57e5a74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes in fire extinguisher maintenance<\/h2>\n<ul><li>A new annual tag on a unit overdue for internal examination or hydrostatic testing; a tag does not mean the unit was opened.<\/li><li>Rehanging a partly used extinguisher because the gauge is still near green.<\/li><li>Recharging with an agent not on the nameplate, or mixing ABC with alkaline powder.<\/li><li>Removing units to the workshop without replacements, leaving areas unprotected for days.<\/li><li>Records held only by the contractor and lost when the contractor changes.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d43c732 elementor-widget elementor-widget-text-editor\" data-id=\"d43c732\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Is a current maintenance tag enough?<\/h3><\/summary><p>No. The annual tag only proves annual maintenance. Also check the internal examination label or verification-of-service collar, the hydrostatic test date on the cylinder, and the monthly inspection record.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can facility staff recharge extinguishers?<\/h3><\/summary><p>NFPA 10 requires maintenance and recharging to be done by a certified person following the manufacturer&#8217;s instructions. A trained staff member without certification may do the monthly inspection.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When does a dry chemical extinguisher need recharging?<\/h3><\/summary><p>After any use, even a few seconds of discharge; when a monthly inspection or maintenance finds low pressure or weight; and at the six-year internal examination of stored-pressure units in mild steel, brazed brass or aluminium shells.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How long must monthly inspection records be kept?<\/h3><\/summary><p>NFPA 10 requires records showing that at least the last 12 monthly inspections were performed. It is good practice to keep each extinguisher&#8217;s history for its whole life, because that history sets the dates for internal examination and testing.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3bd5552 elementor-widget elementor-widget-text-editor\" data-id=\"3bd5552\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>An extinguisher programme is a chain of linked tasks: a monthly check on site, annual maintenance by a certified technician, and internal examination, recharging and hydrostatic testing when due, each leaving a clear mark on the unit and in the records. What convinces a Civil Defense inspector is dates that agree across the unit, the log and the report, not the number of tags. For the extinguisher models AZEIDK supplies, see <a href=\"\/en\/sa\/media-center\/falcon-gold-fire-extinguishers-types\/\">Falcon Gold fire extinguishers<\/a>. For selection and placement rules, see the <a href=\"\/en\/sa\/media-center\/fire-extinguishers-building-safety-guide\/\">extinguisher selection guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66ebba8 elementor-widget elementor-widget-text-editor\" data-id=\"66ebba8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Do you know when your extinguishers are due for internal examination and testing?<\/strong> Send us your extinguisher inventory and latest maintenance report, and we will propose a schedule and contract scope for your facility. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a84b60 elementor-widget elementor-widget-text-editor\" data-id=\"0a84b60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/10\/10_SDR_A2025.pdf\" rel=\"noopener\" target=\"_blank\">NFPA 10 Second Draft Report, Annual 2025 Revision Cycle<\/a> (NFPA), <a href=\"https:\/\/www.osha.gov\/etools\/evacuation-plans-procedures\/emergency-standards\/portable-extinguishers\/hydro\" rel=\"noopener\" target=\"_blank\">Portable Fire Extinguishers: Hydrostatic Testing<\/a> (OSHA), <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-10-standard-development\/10\" rel=\"noopener\" target=\"_blank\">NFPA 10, Standard for Portable Fire Extinguishers<\/a> (NFPA), <a href=\"https:\/\/elm.sa\/ar\/our-business\/digital-products\/Documents\/En\/Salamah%20EN.pdf\" rel=\"noopener\" target=\"_blank\">Salamah platform overview<\/a> (Elm), <a href=\"https:\/\/saso.gov.sa\/en\/Laws-And-Regulations\/Technical_regulations\/Documents\/TR%20-%20Fire%20Control%20Materials%20and%20Equipment.pdf\" rel=\"noopener\" target=\"_blank\">Technical Regulation for Fire Control Materials and Equipment<\/a> (SASO)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire extinguisher maintenance under NFPA 10: monthly checks, annual service, six-year maintenance, recharging, hydrostatic tests, tags and contract clauses.<\/p>\n","protected":false},"author":0,"featured_media":16322,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[],"azeidk_region":[223],"class_list":["post-19316","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19316","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=19316"}],"version-history":[{"count":2,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19316\/revisions"}],"predecessor-version":[{"id":19358,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/19316\/revisions\/19358"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/16322"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=19316"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=19316"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=19316"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=19316"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}