{"id":18495,"date":"2026-11-02T06:00:00","date_gmt":"2026-11-02T06:00:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-02T06:00:00","modified_gmt":"2026-11-02T06:00:00","slug":"tanda-tx7130-beam-detector-egypt","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/eg\/media-center\/tanda-tx7130-beam-detector-egypt\/","title":{"rendered":"TANDA TX7130 Beam Detector in Egypt: Applications and Installation"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18495\" class=\"elementor elementor-18495 elementor-18494 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6022eaa e-con-full az-el-article e-flex e-con e-parent\" data-id=\"6022eaa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce9f023 elementor-widget elementor-widget-text-editor\" data-id=\"ce9f023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">In a high-roof warehouse or a factory hall with overhead cranes, installing and maintaining dozens of point detectors is a recurring burden. The practical alternative is often a single <strong>beam detector<\/strong> that watches a long optical line across the area. The TX7130 from <a href=\"\/en\/eg\/brands\/tanda\/\">TANDA<\/a> is the beam detector AZEIDK Egypt supplies for open areas, warehouses and factories, as part of its <a href=\"\/en\/eg\/solutions\/fire-alarm-systems-egypt\/\">fire detection and alarm solutions<\/a>.<\/p>\n<p>Technical values come from the official TANDA UK datasheet (March 2020).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3371629 elementor-widget elementor-widget-text-editor\" data-id=\"3371629\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>The TANDA TX7130 is a conventional reflective beam detector: transmitter and receiver in one housing, reflector opposite.<\/li><li>It has four ranges, selected with an on-board encoder, from 8 to 100 m: one reflector up to 40 m, four reflectors from 40 to 100 m.<\/li><li>The datasheet states compliance with EN 54-12:2015, LPCB approval and CE marking under the Construction Products Regulation (CE-CPR).<\/li><li>Supply is 20 to 28 V DC. It connects to the panel through separate fire and fault relays, both normally open (NO).<\/li><li>A laser pointer and digital display help alignment; a rigid mounting surface and a clear path still decide success.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e74ea9 elementor-widget elementor-widget-text-editor\" data-id=\"6e74ea9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How the TX7130 reflective beam detector works<\/h2>\n<p>A beam detector is a line detector: it watches a whole path, not a single point. The TX7130 sends an infrared beam to a reflector fixed at the far end. It returns to the receiver in the same housing. When smoke crosses the path, less light returns; past the set threshold, the detector operates its fire relay.<\/p>\n<p>With a single-ended design, all wiring is at one end; the reflector needs no power or cables. The datasheet also lists self-diagnosis of internal faults and automatic compensation for factors that slowly weaken the signal, such as dust build-up, small positional movement and ageing of the transmitter.<\/p>\n<p>The product standard is EN 54-12:2015, for line smoke detectors working on the attenuation of an optical beam. It excludes detectors with opposed components less than 1 m apart, and those whose optical path is set by an integral mechanical connection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c6fd36 elementor-widget elementor-widget-text-editor\" data-id=\"0c6fd36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>TANDA TX7130 technical data from the datasheet<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>Datasheet value<\/th><\/tr><\/thead><tbody><tr><td>Type<\/td><td>Conventional reflective beam detector<\/td><\/tr><tr><td>Compliance and approvals<\/td><td>EN 54-12:2015; LPCB and CE-CPR<\/td><\/tr><tr><td>Operating voltage<\/td><td>20 to 28 V DC<\/td><\/tr><tr><td>Current<\/td><td>23 mA standby, 56 mA during commissioning, 33 mA in alarm<\/td><\/tr><tr><td>Sensitivity levels<\/td><td>2.6 dB (high), 3.8 dB (medium), 5.8 dB (low)<\/td><\/tr><tr><td>Beam path angle<\/td><td>\u00b10.5\u00b0<\/td><\/tr><tr><td>Relays<\/td><td>Fire relay and fault relay, normally open, 2 A at 30 V DC<\/td><\/tr><tr><td>Reset<\/td><td>Less than 2 seconds, by power interruption<\/td><\/tr><tr><td>Alignment aids<\/td><td>Laser pointer, digital display, and LEDs: red for fire, yellow for fault, green for alignment<\/td><\/tr><tr><td>Operating temperature<\/td><td>-10 to 55 \u00b0C<\/td><\/tr><tr><td>Humidity<\/td><td>0 to 95% RH, non-condensing<\/td><\/tr><tr><td>Protection rating<\/td><td>IP30; the datasheet lists IP66 with a glue seal for permanent fixing<\/td><\/tr><tr><td>Dimensions<\/td><td>190.87 \u00d7 126.87 \u00d7 91.96 mm<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d70e27 elementor-widget elementor-widget-text-editor\" data-id=\"7d70e27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Choosing the range and the number of reflectors<\/h2>\n<p>The encoder sets one of four spans, and each span sets the reflector count:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Span<\/th><th>Path length<\/th><th>Path type<\/th><th>Reflectors required<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>8 to 20 m<\/td><td>Short<\/td><td>1 reflector<\/td><\/tr><tr><td>2<\/td><td>20 to 40 m<\/td><td>Short<\/td><td>1 reflector<\/td><\/tr><tr><td>3<\/td><td>40 to 70 m<\/td><td>Normal<\/td><td>4 reflectors<\/td><\/tr><tr><td>4<\/td><td>70 to 100 m<\/td><td>Long<\/td><td>4 reflectors<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Measure the path on site, pick its span, and count reflectors in the BOQ from day one: any path over 40 m needs four per detector. Confirm on ordering how many reflectors and brackets ship per detector; the datasheet lists the bracket and the TX7130-R reflector as accessories.<\/p>\n<p>Sensitivity is a design decision balancing response speed against false alarms; set it with the encoder and record it at commissioning.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0962451 elementor-widget elementor-widget-text-editor\" data-id=\"0962451\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Beam detector applications on Egyptian projects<\/h2>\n<p>The datasheet lists high-ceiling, wide areas such as warehouses, malls, exhibition halls, hotel lobbies, printing houses, garment factories and museums. On Egyptian projects, the main check differs by space:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Space type<\/th><th>Why a beam detector suits it<\/th><th>What to check before installation<\/th><\/tr><\/thead><tbody><tr><td>Warehouses and distribution centres<\/td><td>High ceiling and a large open area with no partitions<\/td><td>Current and future rack heights, and forklifts carrying high loads<\/td><\/tr><tr><td>Factory halls and garment factories<\/td><td>Ceiling hard to reach during operation<\/td><td>Overhead cranes, lint, dust and steam from processes<\/td><\/tr><tr><td>Hangars and steel-frame buildings<\/td><td>Wide spans and high roofs<\/td><td>Structural vibration, thermal expansion, and summer temperature under the steel roof<\/td><\/tr><tr><td>Malls, exhibition halls and hotel lobbies<\/td><td>Fewer devices on the ceiling<\/td><td>Hanging signs, decorations and strong lighting<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Full warehouse protection is covered in <a href=\"\/en\/eg\/media-center\/warehouse-fire-protection-egypt\/\">Warehouse Fire Protection in Egypt<\/a>. To compare point and beam detectors by space, see <a href=\"\/en\/eg\/media-center\/smoke-heat-detector-selection-egypt\/\">Smoke and Heat Detectors: Choosing the Right Detector for Each Space<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fe8271 elementor-widget elementor-widget-text-editor\" data-id=\"8fe8271\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Connecting to the fire alarm panel<\/h2>\n<p>The TX7130 is a conventional detector. It connects to the panel through two separate relays, fire and fault, both normally open and rated 2 A at 30 V DC. Check three points at design stage:<\/p>\n<ul><li><strong>Power:<\/strong> the detector needs 20 to 28 V DC. Include its consumption (23 mA standby, 33 mA in alarm) in the battery and power supply calculation.<\/li><li><strong>Reset:<\/strong> reset is by power interruption (under 2 seconds). Decide early how the panel or supply circuit will cut power to the detector on reset, per the installation wiring diagram.<\/li><li><strong>Compatibility:<\/strong> check how the relays connect to a conventional zone circuit or an addressable input module against both datasheets before supply, whether the panel is <a href=\"\/en\/eg\/brands\/context-plus\/\">Context Plus<\/a> or another make.<\/li><\/ul>\n<p>For the differences, see <a href=\"\/en\/eg\/media-center\/conventional-vs-addressable-fire-alarm-egypt\/\">Conventional and Addressable Fire Alarm Systems<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4097ec elementor-widget elementor-widget-text-editor\" data-id=\"d4097ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which references apply: legal requirement or technical reference?<\/h2>\n<p>The legally binding reference in Egypt is the Egyptian Code for the Design and Implementation of Fire Protection for Buildings \u2014 2026 edition (Ministerial Decree No. 355 of 2026). Its third part covers electrical requirements and detection and alarm. The General Directorate of Civil Protection (Ministry of Interior) reviews drawings and inspects before occupancy.<\/p>\n<p>Beam layout, spacing and distance below the ceiling come from the technical reference the project adopts, such as NFPA 72 (2025 edition) or BS 5839-1:2025, then from the manufacturer&#8217;s instructions. The datasheet cites BS 5839-1 in its 2002 edition; the current edition is 2025, so use the edition named in the project documents. Neither is legally mandatory in Egypt unless the contract or designer adopts it.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0889ce elementor-widget elementor-widget-text-editor\" data-id=\"c0889ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Site preparation and mounting<\/h2>\n<h3>Mounting surface<\/h3>\n<p>With a \u00b10.5\u00b0 beam path angle, small movement at the fixing point throws the beam off over distance. Steel sheeting and purlins expand in summer heat and shake with wind and crane movement. Fix the detector and reflector to concrete columns, or to the main columns and beams of a steel frame, not to cladding sheets or light purlins.<\/p>\n<h3>Environment<\/h3>\n<p>The standard rating, IP30, suits dry indoor spaces; the datasheet gives IP66 only with a glue seal for permanent fixing, so check with the manufacturer before any damp area. With a 55 \u00b0C upper limit, confirm the summer temperature at mounting height under an uninsulated steel roof stays in range.<\/p>\n<h3>Beam path and maintenance access<\/h3>\n<p>Walk the path on site, not only on the drawing. Will racks rise later? Does a crane cross the path? Does sunlight from roof lights hit the detector? Plan access for the technician from the start, by lift platform or walkway.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c083e2 elementor-widget elementor-widget-text-editor\" data-id=\"4c083e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Alignment, testing and commissioning<\/h2>\n<p>A laser pointer shows where to fix the reflector; a digital display shows the returning light strength. The general sequence, following the model&#8217;s installation instructions:<\/p>\n<ol><li><strong>Check:<\/strong> the measured path falls inside the chosen span, with the matching number of reflectors.<\/li><li><strong>Mount:<\/strong> fix detector and reflector on rigid surfaces with no vibration.<\/li><li><strong>Set up:<\/strong> select the span and sensitivity level with the encoder.<\/li><li><strong>Align:<\/strong> aim with the laser pointer, then fine-tune using the digital display and green LED. Current draw here is 56 mA.<\/li><li><strong>Alarm test:<\/strong> simulate smoke by the manufacturer&#8217;s method and confirm the alarm reaches the correct panel zone.<\/li><li><strong>Fault test:<\/strong> block the beam fully, record the detector and panel response, and compare it with the manufacturer&#8217;s instructions.<\/li><li><strong>Record:<\/strong> log span, sensitivity and results in the handover report.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8df6901 elementor-widget elementor-widget-text-editor\" data-id=\"8df6901\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Periodic maintenance<\/h2>\n<p>Automatic compensation handles gradual signal loss but does not replace cleaning where dust builds up.<\/p>\n<ul><li>Clean the lens and reflector by the manufacturer&#8217;s method.<\/li><li>Check alignment on the digital display after any work on the structure or roof.<\/li><li>Walk the path after any change in rack layout or new equipment.<\/li><li>Repeat the alarm and fault tests and record the results.<\/li><\/ul>\n<p>The frequency is set by the approved maintenance programme and the manufacturer&#8217;s instructions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46273a8 elementor-widget elementor-widget-text-editor\" data-id=\"46273a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common beam detector installation mistakes<\/h2>\n<ul><li><strong>Counting one reflector for a long path:<\/strong> paths from 40 to 100 m need four reflectors, according to the datasheet.<\/li><li><strong>Fixing to steel cladding:<\/strong> its movement with heat and wind pushes the beam off the reflector.<\/li><li><strong>Ignoring the reset method:<\/strong> a detector that resets by power interruption needs a circuit designed to allow it.<\/li><li><strong>Using it in damp areas without checking the rating:<\/strong> the standard rating is IP30.<\/li><li><strong>Relying on &#8220;EN 54&#8221; in a catalogue:<\/strong> the submittal needs the datasheet and the model certificate under Part 12.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2362be1 elementor-widget elementor-widget-text-editor\" data-id=\"2362be1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The technical submittal for a beam detector<\/h2>\n<p>For the consultant or civil protection drawings, the submittal usually holds the official datasheet (March 2020, EN 54-12:2015), the model certificate, installation instructions, the panel wiring diagram, and drawings of each beam path with length, span and reflector count. The datasheet is listed under datasheets and technical approval files on the <a href=\"\/en\/eg\/brands\/tanda\/\">TANDA page<\/a>. <a href=\"\/en\/eg\/media-center\/fire-equipment-technical-documents-egypt\/\">Fire Equipment Technical Documents in Egypt<\/a> explains how to prepare this file.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc1815e elementor-widget elementor-widget-text-editor\" data-id=\"fc1815e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the maximum distance the TANDA TX7130 covers?<\/h3><\/summary><p>Up to 100 m between detector and reflector on span 4. From 40 m upwards it needs four reflectors. Beam spacing and distance below the ceiling come from the project&#8217;s technical reference.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does it work with addressable panels?<\/h3><\/summary><p>It is conventional, with fire and fault relay outputs. These can feed a conventional zone circuit or an addressable input module, once the detector, panel and module datasheets are matched before supply.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What approvals does the datasheet list?<\/h3><\/summary><p>Compliance with EN 54-12:2015, LPCB approval and CE marking under the Construction Products Regulation. Request the model certificate for the submittal.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a beam detector suitable for steamy or very dusty areas?<\/h3><\/summary><p>Steam and heavy dust weaken the beam just as smoke does, which raises the risk of false alarms. The designer assesses detection type and sensitivity there, keeping the IP30 rating in mind.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-794c004 elementor-widget elementor-widget-text-editor\" data-id=\"794c004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>The TANDA TX7130 covers up to 100 m over four spans, with one reflector up to 40 m and four beyond, and its datasheet states EN 54-12:2015 compliance and LPCB approval. On site, performance depends on rigid mounting, a clear path, documented alignment and testing, and regular maintenance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cf3c32 elementor-widget elementor-widget-text-editor\" data-id=\"6cf3c32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Planning fire detection for a warehouse or a high-ceiling hall?<\/strong> Send us drawings, path lengths and how the space is used; we will send the datasheet and notes on detector positions and reflector quantities. <a href=\"\/en\/eg\/contact\/\">Talk to the AZEIDK Egypt team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f652ca elementor-widget elementor-widget-text-editor\" data-id=\"9f652ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.tandauk.com\/pdf_fa\/TX7130.pdf\" rel=\"noopener\" target=\"_blank\">TX7130 Conventional Reflective Beam Detector, datasheet (March 2020)<\/a> (TANDA UK); <a href=\"https:\/\/www.sis.se\/en\/produkter\/environment-health-protection-safety\/protection-against-fire\/fire-protection\/ssen54122015\/\" rel=\"noopener\" target=\"_blank\">SS-EN 54-12:2015 Fire detection and fire alarm systems, Part 12: Line detectors using an optical beam<\/a> (Swedish Institute for Standards); <a href=\"https:\/\/knowledge.bsigroup.com\/products\/fire-detection-and-fire-alarm-systems-for-buildings-design-installation-commissioning-and-maintenance-of-systems-in-non-domestic-premises-code-of-practice\" rel=\"noopener\" target=\"_blank\">BS 5839-1:2025 Fire detection and fire alarm systems for buildings, Code of practice<\/a> (BSI)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>TANDA TX7130 beam detector in Egypt: four spans up to 100 m, reflector counts, EN 54-12:2015 datasheet values, panel wiring, mounting, alignment and testing.<\/p>\n","protected":false},"author":0,"featured_media":16511,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[288],"tags":[],"azeidk_region":[226],"class_list":["post-18495","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eg-engineering-guides"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18495","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=18495"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18495\/revisions"}],"predecessor-version":[{"id":19294,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18495\/revisions\/19294"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/16511"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=18495"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=18495"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=18495"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=18495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}