{"id":18463,"date":"2026-11-01T12:00:00","date_gmt":"2026-11-01T12:00:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-01T12:00:00","modified_gmt":"2026-11-01T12:00:00","slug":"falcon-gold-fire-hose-reels-egypt","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/eg\/media-center\/falcon-gold-fire-hose-reels-egypt\/","title":{"rendered":"Falcon Gold Fire Hose Reels and Hoses in Egypt: Types and Installation"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18463\" class=\"elementor elementor-18463 elementor-18462 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2b90b29 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"2b90b29\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c01f1fd elementor-widget elementor-widget-text-editor\" data-id=\"c01f1fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>fire hose reel<\/strong> is usually the first water-based firefighting tool that building occupants can reach before Civil Protection arrives. Its value depends on hose bore and length, reel type, working pressure, and how it is installed and tested.<\/p>\n<p>This guide covers the reel and the hose themselves, as described in the submittal file for <a href=\"\/en\/eg\/brands\/falcon-gold\/\">Falcon Gold at AZEIDK Egypt<\/a>: the types, the values listed in the datasheet, the product certificate, and the installation and inspection points that can be verified.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c107574 elementor-widget elementor-widget-text-editor\" data-id=\"c107574\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>The approved Falcon Gold reel, model FG-651HR, is a manual swinging-arm reel with semi-rigid hose: 25 mm nominal bore, 30 m maximum length.<\/li><li>The reel is covered by LPCB certificate No. 1038BIa, issued by BRE Global to the manufacturer, Falcon Gold, for conformity with EN 671-1:2012. It is approved for use with 12 cabinet models named in the certificate appendix.<\/li><li>The datasheet lists a maximum working pressure of 12 bar for the reel hose, a full brass waterway, and a nozzle that adjusts between jet and spray.<\/li><li>The layflat hoses in the Falcon Gold file come in 38 mm and 65 mm bores, rated 250 psi working pressure, with BS 336 or Storz couplings.<\/li><li>In European practice, hose reel maintenance falls under EN 671-3. European service providers such as Saval describe it as annual maintenance plus a hose test every five years. The legal requirement in Egypt comes from the Egyptian code and Civil Protection requirements.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce0f9c8 elementor-widget elementor-widget-text-editor\" data-id=\"ce0f9c8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Hose reel vs fire hose cabinet: what is the difference?<\/h2>\n<p>On Egyptian sites, &#8220;fire cabinet&#8221; usually means the steel box and everything inside it. The hose reel is the part that holds the hose and feeds it with water: a drum or disc carrying semi-rigid hose, an internal waterway connected to the supply through an inlet valve, and a nozzle at the hose end.<\/p>\n<p>This article stays with the reel, the hose and their connections, not the cabinet body itself. From Falcon Gold, AZEIDK Egypt supplies red single-door fire hose cabinets, manufactured locally and fitted with genuine Falcon Gold components such as the hose reel, hose, nozzle and valve. Hose reels are part of the water network fed by the fire pumps; the wider picture is on our <a href=\"\/en\/eg\/solutions\/fire-fighting-systems-egypt\/\">fire fighting systems<\/a> page.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c398e3 elementor-widget elementor-widget-text-editor\" data-id=\"1c398e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire hose reel types under EN 671-1<\/h2>\n<p>The European standard EN 671-1:2012 covers hose reels with semi-rigid hose installed in buildings, permanently connected to a water supply, for use by the occupants. It classifies reels in two ways.<\/p>\n<h3>By movement: fixed or swinging<\/h3>\n<ul><li><strong>Fixed reel:<\/strong> rotates in one plane only, with a hose guide next to the reel to lead the hose out.<\/li><li><strong>Swinging reel:<\/strong> mounted on an arm, pipe or hinged door, so it swings out of the cabinet towards the fire. EN 671-1 requires a swing of at least 170\u00b0 without leakage.<\/li><\/ul>\n<h3>By inlet valve: manual or automatic<\/h3>\n<ul><li><strong>Manual:<\/strong> the user opens a manual inlet stop valve next to the reel before pulling out the hose.<\/li><li><strong>Automatic:<\/strong> the inlet valve opens by itself when the reel starts to turn.<\/li><\/ul>\n<p>The standard sets semi-rigid hose bores of 19, 25 and 33 mm, and limits reel wheel diameter to 800 mm. The approved Falcon Gold model in the AZEIDK Egypt file is a manual swinging reel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c98289f elementor-widget elementor-widget-text-editor\" data-id=\"c98289f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Falcon Gold fire hose reel: datasheet values<\/h2>\n<p>The Falcon Gold fire hose cabinet submittal, available on the brand page, includes the datasheet for the swinging manual hose reel assembly. The parts list includes the reel disc and hub, swinging arm, manual waterway, angle valve, nozzle model N-04-2, hose and a protective spring at the hose outlet.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>Datasheet value<\/th><\/tr><\/thead><tbody><tr><td>Approved reel model<\/td><td>FG-651HR, manual, swinging arm, cabinet or wall mounted<\/td><\/tr><tr><td>Hose<\/td><td>Semi-rigid, 25 mm x 30 m<\/td><\/tr><tr><td>Reel diameter<\/td><td>600 mm<\/td><\/tr><tr><td>Bracket length<\/td><td>290 mm<\/td><\/tr><tr><td>Reel width<\/td><td>150 mm<\/td><\/tr><tr><td>Hose maximum working pressure<\/td><td>12 bar; burst pressure up to 45 bar<\/td><\/tr><tr><td>Nozzle<\/td><td>Adjustable jet \/ spray<\/td><\/tr><tr><td>Inlet valve<\/td><td>1.5&#8243; x 1&#8243; angle valve, model A-4<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The datasheet also lists a full brass waterway, threaded nipples instead of hose clamps, UV-resistant powder-coated side discs, and an optional pressure gauge at the reel axis.<\/p>\n<p>The manufacturer&#8217;s stated tests are: over 3,000 reel rotations with no visible leakage; 1,000 swings to at least 170\u00b0 with no visible leakage or damage; and a hydrostatic leak test of the reels at 20 bar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49ad53e elementor-widget elementor-widget-text-editor\" data-id=\"49ad53e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>LPCB certificate and approved cabinets<\/h2>\n<p>The same file contains a BRE Global product approval certificate, No. 1038BIa, issued to Falcon Gold General Trading L.L.C in Dubai. It authorises the manufacturer to use the LPCB mark on Falcon Gold hose reels that comply with EN 671-1:2012. The certificate belongs to the product and its manufacturer, not to AZEIDK. The date of first issue is 8 April 2024, and the appendix reference for reel FG-651HR is 1038BIa\/02. The certificate states that its validity can be checked on redbooklive.com; do that check before you submit the approval file.<\/p>\n<p>The appendix also lists the cabinets approved for use with the reel, 12 models in total:<\/p>\n<ul><li>Single door: FG-1001R and FG-1001S (surface mounted), FGR-1001R and FGR-1001S (recessed).<\/li><li>Double door, horizontal: FG-2001R and FG-2001S (surface mounted), FGR-2001R and FGR-2001S (recessed).<\/li><li>Double door, vertical: FGV-3001R and FGV-3001S (surface mounted), FGRV-3001R and FGRV-3001S (recessed).<\/li><\/ul>\n<p>The suffix R means mild steel and S means stainless steel. The approval covers the reel in a cabinet from this list; it does not carry over to any other cabinet. The Falcon Gold cabinets supplied by AZEIDK Egypt are manufactured locally in Egypt with genuine Falcon Gold components, so if the consultant requires the LPCB mark on the complete assembly, check with our team that the supplied cabinet matches a model in the appendix before you submit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70aef9d elementor-widget elementor-widget-text-editor\" data-id=\"70aef9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Layflat hoses and couplings<\/h2>\n<p>Some cabinets combine the reel with a larger layflat hose used from an angle valve outlet. These details come from the manufacturer&#8217;s file; confirm availability within the AZEIDK Egypt supply with our team for each project. The Falcon Gold file describes a Type 1 general-purpose layflat hose: flexible and light, with a circular-woven, high-tenacity polyester jacket and an EPDM lining. The datasheet states compliance with BS 6391 and DIN 14811.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Bore<\/th><th>Available lengths<\/th><th>Working pressure<\/th><th>Proof pressure<\/th><th>Burst pressure<\/th><\/tr><\/thead><tbody><tr><td>1.5&#8243; (38 mm)<\/td><td>15, 23, 30, 45 m and others<\/td><td>250 psi<\/td><td>375 psi<\/td><td>750 psi<\/td><\/tr><tr><td>2.5&#8243; (65 mm)<\/td><td>15, 23, 30, 45 m and others<\/td><td>250 psi<\/td><td>375 psi<\/td><td>750 psi<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Couplings are factory-fitted at both ends, in BS 336 instantaneous or Storz type. The coupling type must match the angle valve outlet on site. The datasheet also shows a vertical cabinet, FGV-3001R, holding a 25 mm x 30 m reel hose rated 12 bar and a 65 mm x 30 m hose rated 17 bar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74f28d3 elementor-widget elementor-widget-text-editor\" data-id=\"74f28d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation: what the standard sets and what the design sets<\/h2>\n<p>Keep three levels of reference separate:<\/p>\n<ul><li><strong>Legal requirement in Egypt:<\/strong> the Egyptian Code for the Design and Implementation of Fire Protection for Buildings \u2014 2026 edition (Ministerial Decree No. 355 of 2026). Its second part covers mechanical firefighting systems. The General Directorate of Civil Protection (Ministry of Interior) approves the drawings. The number of reels, their locations and coverage distances come from the code and the approved design, not from the datasheet.<\/li><li><strong>Product standard:<\/strong> EN 671-1 sets reel performance, dimensions and tests.<\/li><li><strong>Manufacturer instructions:<\/strong> installation dimensions and fixing method, as given in the datasheet.<\/li><\/ul>\n<p>On site, check these points:<\/p>\n<ol><li>Leave enough clear space in front of the cabinet for the reel to swing fully and for the hose to be pulled out freely.<\/li><li>Match the reel dimensions (600 mm diameter, 290 mm bracket, 150 mm width) to the depth and internal space of the approved cabinet.<\/li><li>Make sure network pressure at the reel does not exceed 12 bar, the hose&#8217;s maximum working pressure. In high-rise buildings the lower floors may need pressure reduction, as set by the design.<\/li><li>Check the inlet valve connection for leaks after filling.<\/li><\/ol>\n<p>If the project uses NFPA 14 as its design reference for hose outlets, the 2024 edition keeps the hose valve centre at 0.9 to 1.5 m above the floor and adds a minimum 75 mm clearance around the valve handle. This is a design reference, not an Egyptian legal requirement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65308dd elementor-widget elementor-widget-text-editor\" data-id=\"65308dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Operation and periodic inspection<\/h2>\n<p>The datasheet gives the operating steps: open the inlet valve, pull the hose towards the fire, open the nozzle to jet or spray and aim at the base of the fire. After use, close the valve, drain the water from the hose, rewind it and close the nozzle.<\/p>\n<p>In European practice, maintenance follows EN 671-3, which covers hose reels with semi-rigid hose and layflat hose systems. According to European service providers such as Saval, the standard is built around annual maintenance by a competent person and a hose test every five years. Refer to the standard itself for the test details and pressure. A typical inspection covers free turning and swinging, hose wear, nozzle settings and leaks at the valve or hub. Legally binding frequencies in Egypt come from the code and Civil Protection requirements. For full maintenance programmes, see our <a href=\"\/en\/eg\/media-center\/fire-system-maintenance-inspection-egypt\/\">fire system maintenance guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d50df49 elementor-widget elementor-widget-text-editor\" data-id=\"d50df49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes<\/h2>\n<ul><li><strong>Fitting the reel in a cabinet not listed in the certificate appendix:<\/strong> the approval covers specific combinations, and a substitute cabinet takes the assembly outside it.<\/li><li><strong>Ignoring network pressure:<\/strong> a hose rated 12 bar can see higher pressure on some floors if the design does not check it.<\/li><li><strong>Not checking certificate validity:<\/strong> relying on a PDF copy without checking it on redbooklive.com.<\/li><li><strong>Layflat hose couplings that do not match the valve outlet:<\/strong> a BS 336 coupling will not fit a Storz outlet without an adaptor.<\/li><li><strong>Leaving water in the rolled hose after a test:<\/strong> this goes against the datasheet steps.<\/li><li><strong>Obstructions in front of the cabinet:<\/strong> furniture or stock that stops the reel swinging out or the hose being pulled.<\/li><\/ul>\n<p>For more installation errors across fire networks, see <a href=\"\/en\/eg\/media-center\/fire-system-installation-mistakes-egypt\/\">fire protection installation and testing mistakes in Egypt<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a8923c elementor-widget elementor-widget-text-editor\" data-id=\"3a8923c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What hose size does the Falcon Gold reel use?<\/h3><\/summary><p>The approved model FG-651HR uses semi-rigid hose with a 25 mm nominal bore and a maximum length of 30 m, according to the LPCB certificate appendix and the datasheet.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is the Falcon Gold reel fixed or swinging?<\/h3><\/summary><p>The model in the submittal is a manual swinging-arm reel. It can be installed in a cabinet or on a wall.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which standard does the reel comply with?<\/h3><\/summary><p>EN 671-1:2012, for hose reels with semi-rigid hose, under LPCB certificate No. 1038BIa issued by BRE Global to the manufacturer, Falcon Gold.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the maximum working pressure of the reel hose?<\/h3><\/summary><p>The datasheet lists 12 bar maximum working pressure and a burst pressure of up to 45 bar.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How often should the reel hose be tested?<\/h3><\/summary><p>According to European service providers such as Saval, EN 671-3 is built around annual reel maintenance and a hose test every five years. Binding requirements in Egypt should be checked in the code and Civil Protection requirements.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can I get the datasheet before I submit the approval file?<\/h3><\/summary><p>Yes. The Falcon Gold fire hose cabinet submittal is on the brand page and includes the datasheet and the LPCB certificate.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-225e915 elementor-widget elementor-widget-text-editor\" data-id=\"225e915\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Choosing the right fire hose reel starts with the datasheet: reel type, hose bore and length, and working pressure. Then match the cabinet to the approval list, check network pressure, install with clearance, and inspect regularly.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9586dbe elementor-widget elementor-widget-text-editor\" data-id=\"9586dbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing the hose reel and cabinet submittal for your project?<\/strong> Send us the number of reels, mounting type and network pressure, and we will recommend the right reel and cabinet with the datasheet and LPCB certificate. <a href=\"\/en\/eg\/contact\/\">Talk to the AZEIDK Egypt team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23efd24 elementor-widget elementor-widget-text-editor\" data-id=\"23efd24\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> Material Submittal for Fire Hose Cabinet, Falcon Gold (AZEIDK \/ Falcon Gold), Falcon Gold (AZEIDK Egypt, in Arabic), <a href=\"https:\/\/iteh.es\/catalog\/standards\/sist\/a600cb0a-2d52-4443-9f62-9dd639690944\/sist-en-671-1-2012\" rel=\"noopener\" target=\"_blank\">SIST EN 671-1:2012 Hose reels with semi-rigid hose<\/a> (iTeh Standards), <a href=\"https:\/\/knowledge.bsigroup.com\/products\/fixed-firefighting-systems-hose-systems-hose-reels-with-semi-rigid-hose\" rel=\"noopener\" target=\"_blank\">BS EN 671-1:2012<\/a> (BSI), <a href=\"https:\/\/knowledge.bsigroup.com\/products\/fixed-firefighting-systems-hose-systems-maintenance-of-hose-reels-with-semi-rigid-hose-and-hose-systems-with-lay-flat-hose\" rel=\"noopener\" target=\"_blank\">EN 671-3 Maintenance of hose reels and lay-flat hose systems<\/a> (BSI), <a href=\"https:\/\/www.saval.nl\/en\/management-maintenance\/services\/fire-hose-reel-maintenance\/\" rel=\"noopener\" target=\"_blank\">Fire hose reel maintenance<\/a> (Saval), and <a href=\"https:\/\/nfsa.org\/2024\/04\/17\/standpipe-hose-connections-and-nfpa-14\/\" rel=\"noopener\" target=\"_blank\">Clearances: Standpipe Hose Connections and NFPA 14<\/a> (NFSA)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Falcon Gold fire hose reel in Egypt: FG-651HR swinging reel with 25 mm x 30 m hose, LPCB approval to EN 671-1, layflat hoses, installation and inspection.<\/p>\n","protected":false},"author":0,"featured_media":18049,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[287],"tags":[],"azeidk_region":[226],"class_list":["post-18463","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eg-technical-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=18463"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18463\/revisions"}],"predecessor-version":[{"id":19225,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18463\/revisions\/19225"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/18049"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=18463"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=18463"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=18463"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=18463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}