{"id":18367,"date":"2026-11-01T09:15:00","date_gmt":"2026-11-01T09:15:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-01T09:15:00","modified_gmt":"2026-11-01T09:15:00","slug":"high-rise-residential-fire-safety","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/high-rise-residential-fire-safety\/","title":{"rendered":"Fire Safety in High-Rise Residential Towers"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18367\" class=\"elementor elementor-18367 elementor-18366 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91e3353 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"91e3353\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-be334e4 elementor-widget elementor-widget-text-editor\" data-id=\"be334e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">In a residential tower, hundreds of people sleep above the reach of Civil Defense ladders, and most of them do not know where the fire alarm panel is or how stair pressurization works. <strong>High-rise residential fire safety<\/strong> therefore depends on systems that work without waiting for outside help: sprinklers that keep a fire inside the apartment, alarms that wake sleeping residents, escape routes that stay clear of smoke, and services that let firefighters operate from inside the building.<\/p>\n<p>This article focuses on what sets residential high-rises apart, the package of requirements the International Building Code places on high-rise buildings, and what owners and owners&#8217; associations need after handover.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c18f72 elementor-widget elementor-widget-text-editor\" data-id=\"1c18f72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>The International Building Code defines a high-rise as a building with an occupied floor more than 23 m (75 ft) above the lowest level of fire department vehicle access.<\/li><li>The high-rise package includes sprinklers throughout, emergency voice\/alarm communication, a fire command center, standby and emergency power, smokeproof stairs and fire service access elevators above 36.6 m.<\/li><li>The apartment is the first line of protection: fire-rated walls and self-closing fire doors, quick-response sprinklers and detectors that do not alarm from cooking vapour.<\/li><li>NFPA data show that cooking is a leading cause of home fires, so kitchens deserve special attention in design and resident awareness.<\/li><li>The Saudi code is built on ICC codes; confirm all values in the Saudi edition adopted before design.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32266d0 elementor-widget elementor-widget-text-editor\" data-id=\"32266d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When is a residential building a high-rise?<\/h2>\n<p>The International Building Code (IBC) defines a high-rise as a building with an occupied floor located more than 23 m above the lowest level of fire department vehicle access, measured from that level to the floor of the highest occupied storey. MeyerFire explains that many fire departments use aerial apparatus of about 30 m and that the threshold allows for the vehicle being parked some distance from the building, so firefighting above it is managed from inside.<\/p>\n<p>The Saudi code is based on International Code Council (ICC) models, and projects apply the building code SBC 201 and the fire code SBC 801 together. The values here come from the IBC and should be treated as reference values until checked against the adopted Saudi edition. For the structure of the Saudi code, see our <a href=\"\/en\/sa\/media-center\/saudi-building-code-sbc-801-fire-protection\/\">SBC 801 guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b85bd9 elementor-widget elementor-widget-text-editor\" data-id=\"7b85bd9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What makes residential towers different<\/h2>\n<ul><li><strong>Sleeping, untrained occupants:<\/strong> unlike offices, residents are present at night, including children, older people and people with disabilities, and they rarely practise evacuation.<\/li><li><strong>A daily ignition source in every unit:<\/strong> NFPA reports show cooking at the top of home fire and injury causes.<\/li><li><strong>Resident alterations:<\/strong> removing closers from apartment doors, changing false ceilings, or storing belongings in stairs and corridors.<\/li><li><strong>Balconies and facades:<\/strong> these can carry fire vertically outside the building if cladding or balcony contents are combustible.<\/li><li><strong>Shared services:<\/strong> electrical and HVAC shafts, refuse chutes and podium car parks, all potential smoke paths.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2515c elementor-widget elementor-widget-text-editor\" data-id=\"7b2515c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The IBC high-rise requirements package<\/h2>\n<p>Section 403 of the IBC brings the high-rise requirements together. The table summarises the main items, mainly as they appear in the IBC text adopted in Massachusetts (780 CMR), with ICC sources where noted:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Area<\/th><th>Requirement<\/th><\/tr><\/thead><tbody><tr><td>Sprinklers<\/td><td>Sprinklered throughout, with a secondary water supply where the code requires one. Above 128 m, each sprinkler zone is fed by at least two risers serving alternate floors<\/td><\/tr><tr><td>Pump supply<\/td><td>In buildings more than 128 m tall, fire pumps connected to two water mains in different streets, with a limited exception (per the ICC wording of Section 403.3.2)<\/td><\/tr><tr><td>Detection and alarm<\/td><td>Smoke detection, a fire alarm system and an emergency voice\/alarm communication system<\/td><\/tr><tr><td>Responder communications<\/td><td>In-building radio coverage for emergency responders and a fire command center<\/td><\/tr><tr><td>Smoke removal<\/td><td>Manually operable windows or panels around each floor, mechanical exhaust at one air change every 15 minutes, or an approved equivalent<\/td><\/tr><tr><td>Power<\/td><td>Standby and emergency power for the command center, alarm, exit lighting and elevators, with any indoor generator in a room enclosed by two-hour fire barriers<\/td><\/tr><tr><td>Stairways<\/td><td>Stair remoteness; stair doors locked from the stair side must all unlock from the command center; two-way communication at least every fifth floor where doors are locked; smokeproof enclosures for floors above 23 m; luminous egress path markings in specified occupancies, which do not include Group R-2 residential under 2024 IBC Section 1025.1<\/td><\/tr><tr><td>Elevators<\/td><td>Where an occupied floor is more than 36.6 m up, at least two fire service access elevators, or all elevators if fewer<\/td><\/tr><\/tbody><\/table><\/div>\n<p>One residential detail: the IBC requires an additional exit stairway in buildings over 128 m in height, but exempts Group R-2 residential occupancies. Requirements vary between code editions and local amendments, so refer to the corresponding Saudi text for each item.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b496474 elementor-widget elementor-widget-text-editor\" data-id=\"b496474\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The apartment as a fire compartment<\/h2>\n<p>The aim in a residential tower is to keep the fire inside the apartment where it starts, so that not every resident has to evacuate at once. That takes several elements working together:<\/p>\n<ul><li><strong>Separation:<\/strong> fire-rated walls and floors between units, with penetrations around pipes and cables sealed with approved materials.<\/li><li><strong>Apartment entrance door:<\/strong> a fire-rated door with an approved frame and hardware and a self-closer. Any alteration can void its rating.<\/li><li><strong>Sprinklers:<\/strong> residential or quick-response sprinklers inside units, designed to NFPA 13. NFPA 13R, as its title indicates, is intended for low-rise residential buildings and is not used for towers.<\/li><li><strong>Detection in the unit:<\/strong> single- or multiple-station smoke alarms inside the apartment, covered by the NFPA 72 chapter on single- and multiple-station alarms, and system detectors in corridors and common areas. Detectors near kitchens are chosen carefully so they do not alarm from cooking and teach residents to ignore them.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edd3b15 elementor-widget elementor-widget-text-editor\" data-id=\"edd3b15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Alarm and evacuation<\/h2>\n<p>Evacuating an entire tower at once fills the stairs and slows firefighters coming up. Towers therefore often use phased evacuation: the fire floor and adjacent floors leave first, while other residents receive voice messages telling them what to do. This is what an emergency voice\/alarm communication system makes possible, as explained in our article on <a href=\"\/en\/sa\/media-center\/voice-evacuation-alarm-systems\/\">voice evacuation alarm systems<\/a>. Under NFPA 72 (as in the 2013 edition), the alarm in bedrooms must reach 75 dBA at the pillow.<\/p>\n<p>Stairs stay usable through pressurization or smokeproof design, as covered in our article on <a href=\"\/en\/sa\/media-center\/smoke-control-stair-pressurization\/\">smoke control and stair pressurization<\/a>. For people who cannot use the stairs, areas of refuge with communication points to the command center are provided; see our article on <a href=\"\/en\/sa\/media-center\/fire-telephone-disabled-refuge-systems\/\">fire telephones and refuge areas<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5d6963 elementor-widget elementor-widget-text-editor\" data-id=\"a5d6963\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Water supply, standpipes and pressure zones<\/h2>\n<p>A tall building cannot be served at a single pressure. The pressure needed at the top floor would be far too high at the lower floors, so the system is divided into pressure zones, pressure-reducing valves are used at outlets where needed, and intermediate pumps or tanks may be added. Standpipes and fire department outlets are designed to NFPA 14 to suit the way Civil Defense fights fires from inside the building. See our <a href=\"\/en\/sa\/media-center\/nfpa-14-standpipe-hose-systems\/\">NFPA 14 standpipe guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-574cbb4 elementor-widget elementor-widget-text-editor\" data-id=\"574cbb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Facades and balconies<\/h2>\n<p>Facade fires in residential towers around the world have shown that a fire can bypass all internal protection if it finds a path up the outside wall. The IBC relies on the NFPA 285 test to evaluate flame spread in exterior walls that contain combustible components, such as some cladding panels and insulation. In practice, facade materials should come with test reports that match the assembly actually installed, not just the panel on its own, and the gaps between the facade and slab edges should be sealed with fire-stopping materials.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c48fbe elementor-widget elementor-widget-text-editor\" data-id=\"0c48fbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>After handover: the owner&#8217;s and residents&#8217; responsibilities<\/h2>\n<p>Most systems in a residential tower are out of sight, so their condition can decline without anyone noticing. The owner or owners&#8217; association needs:<\/p>\n<ol><li>A maintenance contract covering fire alarm, sprinklers, pumps, stair pressurization and elevators. See the scope of <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">AZEIDK annual maintenance contracts<\/a>.<\/li><li>Safety licensing and renewals through the Civil Defense Salamah platform.<\/li><li>Routine checks of apartment and stair doors to confirm they self-close.<\/li><li>No storage in stairs, corridors or service rooms.<\/li><li>Resident awareness of evacuation messages, exit locations and refuge areas.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7b506f elementor-widget elementor-widget-text-editor\" data-id=\"f7b506f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes in residential towers<\/h2>\n<ul><li>Designing a tower to low-rise residential rules, such as using NFPA 13R or omitting voice evacuation.<\/li><li>Placing smoke detectors next to open kitchens, leading to repeated false alarms.<\/li><li>Apartment fire doors without closers, or with altered locks.<\/li><li>Standpipe pressure zones without suitable pressure-reducing valves.<\/li><li>Facade materials approved as a single panel without testing of the full assembly.<\/li><li>Open gaps between the facade and slab edges or around shafts.<\/li><li>No maintenance programme after handover, and responsibility passing from developer to owners&#8217; association without documentation.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cb290c elementor-widget elementor-widget-text-editor\" data-id=\"0cb290c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK can help<\/h2>\n<p>For residential towers, AZEIDK supplies Context Plus fire alarm systems, including the SigTEL fire telephone and refuge communication points, Fire World fire alarm cables, TYCO and Victaulic sprinklers, Falcon Gold fire hose cabinets and Jack Pump fire pumps. We help with design and calculations, equipment selection and Civil Defense approval files, and with routine maintenance once the building is occupied.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a1b3fa elementor-widget elementor-widget-text-editor\" data-id=\"9a1b3fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Does every residential tower need voice evacuation?<\/h3><\/summary><p>The IBC requires emergency voice\/alarm communication in high-rise buildings. Check the corresponding requirement in the Saudi code adopted for the project.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is the whole tower evacuated when the alarm sounds?<\/h3><\/summary><p>Many towers are designed for phased evacuation, starting with the fire floor and adjacent floors. The plan is set in the approved design and evacuation strategy.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can elevators be used for evacuation?<\/h3><\/summary><p>Ordinary elevators are normally not used. Fire service access elevators are for Civil Defense crews, and occupant evacuation elevators are a special case the code allows only with a specific design.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Who is responsible for maintaining fire systems in the tower?<\/h3><\/summary><p>The owner or the body that manages the building, such as an owners&#8217; association. This should be documented at handover and in the maintenance contract.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are sprinklers inside apartments necessary if corridors are protected?<\/h3><\/summary><p>A high-rise under the IBC is sprinklered throughout, and fires usually start inside a unit, so protecting the unit is the foundation.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edd4633 elementor-widget elementor-widget-text-editor\" data-id=\"edd4633\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Safety in a residential tower relies on successive layers: an apartment that contains the fire, sprinklers that control it early, alarms that reach and guide sleeping residents, smoke-free stairs, and services that let Civil Defense work from inside. Each layer needs a design that matches the Saudi code, documented installation and continued maintenance after people move in.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17d0412 elementor-widget elementor-widget-text-editor\" data-id=\"17d0412\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Working on or managing a residential tower?<\/strong> Send us the drawings or a current condition report, and we will review the protection systems and propose what is needed for design or maintenance. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-702bf68 elementor-widget elementor-widget-text-editor\" data-id=\"702bf68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/iccsafe.org\/?p=194789\" rel=\"noopener\" target=\"_blank\">Talking in Code: High-rise building definition<\/a> (International Code Council); <a href=\"https:\/\/www.meyerfire.com\/university\/what-is-a-highrise\" rel=\"noopener\" target=\"_blank\">What is a High-Rise?<\/a> (MeyerFire); <a href=\"https:\/\/regulations.justia.com\/states\/massachusetts\/780-cmr\/chapter-4\/section-403\/subsection-403-4\" rel=\"noopener\" target=\"_blank\">780 CMR 403.4 Emergency systems (high-rise)<\/a>, <a href=\"https:\/\/regulations.justia.com\/states\/massachusetts\/780-cmr\/chapter-4\/section-403\/subsection-403-5\" rel=\"noopener\" target=\"_blank\">403.5 Means of egress<\/a> and <a href=\"https:\/\/regulations.justia.com\/states\/massachusetts\/780-cmr\/chapter-4\/section-403\/subsection-403-3\" rel=\"noopener\" target=\"_blank\">403.3 Automatic sprinkler system<\/a> (Justia); <a href=\"https:\/\/bellevue.municipal.codes\/BCC\/23.10.403.6.1\" rel=\"noopener\" target=\"_blank\">IBC 403.6.1 Fire service access elevator<\/a> (City of Bellevue); <a href=\"https:\/\/ansi.org\/standards-news\/member-updates\/2023\/07\/7-28-23-nfpa-announces-fire-protection-week-theme\" rel=\"noopener\" target=\"_blank\">NFPA announces Fire Prevention Week theme (cooking safety)<\/a> (ANSI\/NFPA, 2023); <a href=\"https:\/\/iccsafe.org\/wp-content\/uploads\/twb\/403_3_2-High-rise-sprinkler-water-supply.pdf\" rel=\"noopener\" target=\"_blank\">403.3.2 High-rise sprinkler water supply<\/a> (International Code Council); <a href=\"https:\/\/idighardware.com\/2026\/05\/decoded-luminous-egress-path-markings-2\/\" rel=\"noopener\" target=\"_blank\">Decoded: Luminous Egress Path Markings (2024 IBC 1025.1)<\/a> (iDigHardware); <a href=\"https:\/\/shop.iccsafe.org\/nfpa-13r-2025-standard-for-the-installation-of-sprinkler-systems-in-low-rise-residential-occupancies.html\" rel=\"noopener\" target=\"_blank\">NFPA 13R-2025 Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies<\/a> (ICC Shop); <a href=\"https:\/\/www.iccsafe.org\/building-safety-journal\/\/beyond-the-wall-decoding-the-2024-international-building-code-and-nfpa-285-fire-safety-evolution\" rel=\"noopener\" target=\"_blank\">Beyond the wall: the 2024 IBC and NFPA 285<\/a> (ICC Building Safety Journal)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Residential tower fire safety: the 23 m high-rise definition, IBC Section 403 requirements, apartment protection, phased evacuation and facade risks.<\/p>\n","protected":false},"author":0,"featured_media":16549,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[],"azeidk_region":[223],"class_list":["post-18367","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18367","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=18367"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18367\/revisions"}],"predecessor-version":[{"id":19161,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18367\/revisions\/19161"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/16549"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=18367"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=18367"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=18367"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=18367"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}