{"id":18166,"date":"2026-10-30T17:40:05","date_gmt":"2026-10-30T17:40:05","guid":{"rendered":"https:\/\/azeidkgroup.com\/?p=18166"},"modified":"2026-10-30T17:40:07","modified_gmt":"2026-10-30T17:40:07","slug":"fire-equipment-technical-documents-egypt","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/eg\/media-center\/fire-equipment-technical-documents-egypt\/","title":{"rendered":"Fire Equipment Technical Documents in Egypt: Datasheets, Certificates and Submittals"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18166\" class=\"elementor elementor-18166 elementor-18165 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b7adc29 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"b7adc29\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e3aa27 elementor-widget elementor-widget-text-editor\" data-id=\"6e3aa27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">Every item of fire protection equipment arrives with papers: datasheet, catalogue, installation and O&amp;M manuals, test reports, certificates, and the material submittal the consultant reviews. Understanding <strong>fire equipment technical documents<\/strong> shortens approval time, stops the wrong model being delivered, and protects the owner at handover and during maintenance.<\/p>\n<p>This guide explains each document, how to verify certificates at source, and what consultants check.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-707593a elementor-widget elementor-widget-text-editor\" data-id=\"707593a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>A datasheet describes one specific model with its numbers. A catalogue presents the whole product family. A submittal needs the datasheet, not just the catalogue.<\/li><li>For many listed products, the installation and O&amp;M manuals are part of the listing conditions. Installing outside them can take the equipment outside its approval.<\/li><li>A certificate covers a specific model and configuration. Verify it in the issuing body&#8217;s official directory, not from a logo in a catalogue.<\/li><li>The legal reference in Egypt is Building Law No. 119 of 2008 and the 2026 Egyptian fire code. UL, FM, LPCB and EN are technical references that project specifications usually call for.<\/li><li>A good submittal links every BOQ item to a document that proves compliance.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c45e2a8 elementor-widget elementor-widget-text-editor\" data-id=\"c45e2a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why technical documents matter on fire protection projects<\/h2>\n<p>Fire protection equipment only operates in a rare event, so daily use proves nothing. The evidence that it will perform as designed is in the documents: a type test on a sample of the model, a certificate from an independent body that audits production, and manufacturer instructions that set installation and operating conditions.<\/p>\n<p>In Egypt, Building Law No. 119 of 2008 and its executive regulations require the permit applicant to apply fire protection requirements under the Egyptian code. The current code is the Egyptian Code for the Design and Implementation of Fire Protection for Buildings \u2014 2026 edition (Ministerial Decree No. 355 of 2026). The General Directorate of Civil Protection (Ministry of Interior) reviews and approves system drawings and inspects the building before occupancy. The list of documents needed for each item is set by the project specification, the consultant and the authority. For the legal framework in more detail, see our <a href=\"\/en\/eg\/media-center\/fire-protection-requirements-egypt\/\">article on fire protection requirements in Egypt<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa9c0c5 elementor-widget elementor-widget-text-editor\" data-id=\"fa9c0c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Datasheet vs product catalogue<\/h2>\n<p>A <strong>datasheet<\/strong> (technical data sheet or cut sheet) is a one- to few-page document for one model or a close group of models. It gives the model number, sizes, rated working pressure, flow, materials, dimensions, limits of use, listing or approval status, and often an ordering table with a code for each configuration. You compare it against the BOQ and specification.<\/p>\n<p>A <strong>product catalogue<\/strong> presents a whole product family or range. It helps early selection but does not prove compliance: a logo on the cover may apply to some models only.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Document<\/th><th>Purpose<\/th><th>Usually needed<\/th><\/tr><\/thead><tbody><tr><td>Product catalogue<\/td><td>Introduces the product family and its options<\/td><td>Concept design and option comparison<\/td><\/tr><tr><td>Datasheet<\/td><td>Performance and specifications of a specific model<\/td><td>Material submittal and BOQ review<\/td><\/tr><tr><td>Installation manual<\/td><td>Installation steps, limits and conditions<\/td><td>Before installation and during supervision<\/td><\/tr><tr><td>O&amp;M manual<\/td><td>Operation, testing, maintenance and spare parts<\/td><td>At handover and for the life of the system<\/td><\/tr><tr><td>Test report<\/td><td>Results of testing a sample or unit to a stated standard or procedure<\/td><td>When a specific performance or a specific unit must be proven<\/td><\/tr><tr><td>Product or listing certificate<\/td><td>Proof that the model passed a standard with an independent body<\/td><td>Submittal, verified in the official directory<\/td><\/tr><tr><td>Material submittal<\/td><td>Brings all of the above together per item and maps it to the specification<\/td><td>Before delivery, per the consultant&#8217;s procedure<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-027a407 elementor-widget elementor-widget-text-editor\" data-id=\"027a407\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation manual and O&amp;M manual<\/h2>\n<p>The <strong>installation manual<\/strong> sets the permitted orientation, clearances, fixing method, compatible components, tightening torques and pre-commissioning steps. For many listed products, the manufacturer&#8217;s instructions form part of the listing, so installing against them can put a listed item outside its approval. So it is good practice to include the installation manual in the submittal, especially for specially listed equipment whose use is defined by the manufacturer&#8217;s instructions.<\/p>\n<p>The <strong>operation and maintenance (O&amp;M) manual<\/strong> covers operation, periodic testing, troubleshooting and recommended spares. It belongs in the handover file as the basis of maintenance, alongside NFPA 25 (water-based systems) and NFPA 72 (fire alarm).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e15fe79 elementor-widget elementor-widget-text-editor\" data-id=\"e15fe79\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Test reports and product certificates<\/h2>\n<h3>Test reports<\/h3>\n<p>A test report records the result of testing a specific sample or unit to a stated standard or procedure. A fire pump example is the manufacturer&#8217;s certified shop test curve for that pump. Industry guidance requires it to be available before the field acceptance test, so site readings can be compared against it. It proves only what was tested, not ongoing production control.<\/p>\n<h3>International listings and approvals<\/h3>\n<ul><li><strong>UL:<\/strong> check the listing in UL Product iQ by manufacturer and model number.<\/li><li><strong>FM Approvals:<\/strong> check the FM Approval Guide. Each product category has its own approval standard with a class number.<\/li><li><strong>LPCB:<\/strong> check the certificate in RedBookLive, published by BRE.<\/li><li><strong>BSI Kitemark:<\/strong> check the certificate number in the BSI directory.<\/li><\/ul>\n<h3>European standards and CE marking<\/h3>\n<p>Fire detection products covered by the EN 54 series are placed on the European market with CE marking under the EU Construction Products Regulation. The manufacturer issues a Declaration of Performance (DoP) based on a certificate of constancy of performance from a Notified Body, which tests the product and audits factory production control. The new EU regulation 2024\/3110 has applied in full since 7 January 2026, with a gradual transition from regulation 305\/2011. Ask for the certificate and the DoP, not just &#8220;complies with EN 54&#8221;.<\/p>\n<h3>The Egyptian quality mark<\/h3>\n<p>The Egyptian Organization for Standardization and Quality (EOS) licenses its quality mark for products that meet the relevant standards and conditions. One example is the <a href=\"\/en\/eg\/brands\/pyramid\/\">PYRAMID<\/a> extinguishers supplied by AZEIDK Egypt: several types carry the Egyptian quality mark and conform to Egyptian standards such as ES 8442\/2021 for dry powder extinguishers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-219b05b elementor-widget elementor-widget-text-editor\" data-id=\"219b05b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The material submittal: what goes in it?<\/h2>\n<p>The material submittal is the package the contractor or supplier sends to the consultant before delivery. It usually includes:<\/p>\n<ol><li>A cover letter giving the BOQ item number and the matching specification clause.<\/li><li>The datasheet for the proposed model, with the model, size and required options marked on the page.<\/li><li>Current listing or approval certificates, or the file number that allows verification.<\/li><li>A compliance statement comparing each specification clause with what the model offers, with any deviation stated clearly.<\/li><li>The installation manual, and shop drawings or hydraulic calculations where needed.<\/li><li>A certificate of origin or manufacturer&#8217;s authorisation letter if the specification asks for one.<\/li><\/ol>\n<p>The consultant sets the format and response codes (approved, approved as noted, or revise and resubmit).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b416365 elementor-widget elementor-widget-text-editor\" data-id=\"b416365\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to read and verify fire equipment technical documents<\/h2>\n<p>Reading fire equipment technical documents starts with an exact match: the datasheet model is the delivered model, with the same size, options and ends. Then:<\/p>\n<ol><li><strong>Match the numbers:<\/strong> model and ordering code against the quotation, the invoice and the nameplate on the equipment.<\/li><li><strong>Read the limits of use:<\/strong> rated working pressure, temperature range, mounting orientation and compatibility with other components.<\/li><li><strong>Check the certificate at source:<\/strong> search the issuing body&#8217;s official directory by manufacturer and model, and confirm the listing covers the size and end connections you need.<\/li><li><strong>Check the date and revision:<\/strong> datasheets are updated, and an old revision may show an approval that is no longer valid.<\/li><li><strong>Separate &#8220;designed to&#8221; from &#8220;listed by&#8221;:<\/strong> &#8220;designed to NFPA 20&#8221; does not mean a pump is UL listed or FM approved.<\/li><\/ol>\n<p>For step-by-step checks in the UL, FM, LPCB and BSI databases, see our <a href=\"\/en\/eg\/media-center\/ul-fm-certifications-verification-egypt\/\">guide to verifying UL and FM certifications<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2cb244 elementor-widget elementor-widget-text-editor\" data-id=\"f2cb244\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What does the consultant check in a submittal?<\/h2>\n<ul><li>That the model matches the specification and the BOQ, including any approvals the specification names.<\/li><li>The pressure rating against the highest actual pressure at the equipment location.<\/li><li>Compatibility between components, such as detectors and modules with the fire alarm panel, or alarm valve trim with its valve model.<\/li><li>For pumps: the rated duty point, the performance curve, driver and controller type, and listing status if required.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e7ecd0 elementor-widget elementor-widget-text-editor\" data-id=\"6e7ecd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes with technical documents<\/h2>\n<ul><li>Submitting a general catalogue instead of the datasheet for the specific model.<\/li><li>Relying on a UL or FM logo in a catalogue without a file number or a directory check.<\/li><li>Submitting an old datasheet revision that differs from the model actually available.<\/li><li>Delivering a model that differs from the approved submittal, such as a non-listed version of a model that also has a listed version.<\/li><li>No compliance statement, so review is delayed.<\/li><li>Not handing O&amp;M manuals to the owner, so maintenance starts without a reference.<\/li><li>Confusing a quality mark licence for a specific product with an approval of the supplying company.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b48c26e elementor-widget elementor-widget-text-editor\" data-id=\"b48c26e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Product documents at AZEIDK Egypt<\/h2>\n<p>AZEIDK Egypt states approvals per model, backed by the relevant document. Approvals for <a href=\"\/en\/eg\/brands\/context-plus\/\">Context Plus<\/a> products vary between EN 54 conformity and UL listing depending on the model, as shown on each datasheet. HoodSafer kitchen systems hold BSI Kitemark certificate KM 767382, which can be checked in the BSI directory. 3PUMP fire pump sets supplied in Egypt are Non-UL (non-listed); UL-listed or FM-approved versions are supplied on request. You can find available documents on our <a href=\"\/en\/eg\/documents\/\">documents page<\/a> and approvals on our <a href=\"\/en\/eg\/certifications\/\">certifications page<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d2a998a elementor-widget elementor-widget-text-editor\" data-id=\"d2a998a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Is a catalogue enough for a material submittal?<\/h3><\/summary><p>Usually not. A catalogue covers the whole family. The consultant needs the datasheet for the specific model with proof of its approval status, plus anything else the project specification asks for.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are UL or FM certificates legally required in Egypt?<\/h3><\/summary><p>The legal reference is the Building Law, the Egyptian fire code and Civil Protection requirements. UL and FM are technical references that many project specifications and insurers require. Check the specification of each project.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the difference between a test report and a listing?<\/h3><\/summary><p>A test report proves the result of testing a sample or unit. A listing or approval means the model passed a standard with an independent body that audits production regularly, and it appears in that body&#8217;s official directory.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How do I know a datasheet is current?<\/h3><\/summary><p>Check the revision number and date, ask the manufacturer or supplier for the latest version, and compare the stated approvals with the issuing body&#8217;s directory on the day you review.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which documents should the owner keep after handover?<\/h3><\/summary><p>O&amp;M manuals, approved datasheets, as-built drawings, acceptance test results and equipment certificates. These are the reference for maintenance and any later changes.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1f63a4 elementor-widget elementor-widget-text-editor\" data-id=\"a1f63a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Each document has a job: the catalogue introduces, the datasheet proves compliance, the installation manual sets installation conditions, the O&amp;M manual covers life after handover, and the certificate proves approval once checked at source. A submittal that links every item to its document cuts review cycles and late surprises.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37922ad elementor-widget elementor-widget-text-editor\" data-id=\"37922ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing a material submittal for fire protection equipment?<\/strong> Send us your BOQ items and specification, and we will provide datasheets and the approval status of each proposed model. <a href=\"\/en\/eg\/contact\/\">Talk to the AZEIDK Egypt team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-76dda91 elementor-widget elementor-widget-text-editor\" data-id=\"76dda91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.zvei.org\/fileadmin\/user_upload\/Presse_und_Medien\/Publikationen\/2015\/maerz\/Guideline_Construction_Products_Regulation__EU__305\/Guideline-Construction-Products-Regulation-EU-305-20122-Euralarm-V2015.pdf\" rel=\"noopener\" target=\"_blank\">Guideline: Construction Products Regulation (EU) 305\/2011<\/a> (Euralarm \/ ZVEI); <a href=\"https:\/\/single-market-economy.ec.europa.eu\/sectors\/construction\/construction-products-regulation-cpr\/cpr-overview_en\" rel=\"noopener\" target=\"_blank\">Construction Products Regulation (CPR) overview<\/a> (European Commission); <a href=\"https:\/\/www.eos.org.eg\/ckfinder\/userfiles\/files\/%D8%B4%D8%B1%D9%88%D8%B7%20%D8%A7%D8%B3%D8%AA%D8%AE%D8%AF%D8%A7%D9%85%20%D8%B9%D9%84%D8%A7%D9%85%D8%A9%20%D8%A7%D9%84%D8%AC%D9%88%D8%AF%D8%A9.pdf\" rel=\"noopener\" target=\"_blank\">Conditions for using the quality mark<\/a> (Egyptian Organization for Standardization and Quality, in Arabic); <a href=\"https:\/\/fmapprovals.com\/Resources\/Insights\/Guide-Release\" rel=\"noopener\" target=\"_blank\">Approval Guide Improves Access to FM Approved Products<\/a> (FM Approvals); <a href=\"https:\/\/qac-cms.axaxl.com\/-\/media\/axaxl\/files\/pdfs\/prc-guidelines\/prc-14\/prc14211centrifugalfirepumpacceptancetestsv1.pdf\" rel=\"noopener\" target=\"_blank\">PRC.14.2.1.1 Centrifugal Fire Pump Acceptance Tests<\/a> (AXA XL Risk Consulting); <a href=\"https:\/\/productiq.ulprospector.com\" rel=\"noopener\" target=\"_blank\">UL Product iQ<\/a> (UL Solutions); <a href=\"https:\/\/www.redbooklive.com\" rel=\"noopener\" target=\"_blank\">RedBookLive<\/a> (BRE \/ LPCB)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire equipment technical documents in Egypt: datasheets vs catalogues, installation and O&#038;M manuals, test reports, UL\/FM\/LPCB certificates and submittals.<\/p>\n","protected":false},"author":2,"featured_media":16291,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[289],"tags":[],"azeidk_region":[226],"class_list":["post-18166","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eg-codes-standards"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=18166"}],"version-history":[{"count":2,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18166\/revisions"}],"predecessor-version":[{"id":18202,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18166\/revisions\/18202"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/16291"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=18166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=18166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=18166"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=18166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}