{"id":18077,"date":"2026-10-29T22:17:15","date_gmt":"2026-10-29T22:17:15","guid":{"rendered":"https:\/\/azeidkgroup.com\/?p=18077"},"modified":"2026-10-29T23:06:33","modified_gmt":"2026-10-29T23:06:33","slug":"fire-extinguisher-types-uses-egypt","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/eg\/media-center\/fire-extinguisher-types-uses-egypt\/","title":{"rendered":"Types of Fire Extinguishers and Their Uses: Choosing by Hazard"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18077\" class=\"elementor elementor-18077 elementor-18055 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-82bf3d0 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"82bf3d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-41756e6 elementor-widget elementor-widget-text-editor\" data-id=\"41756e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">Choosing a fire extinguisher starts with what could burn in the space, not with size or price. Knowing the types of fire extinguishers and their uses prevents dangerous mistakes, such as water on an electrical fire or CO2 on a fryer fire. This guide covers the European and American fire classes, the main extinguisher types, and how to select, place and maintain them.<\/p>\n<p>A portable extinguisher is for the first minutes of a fire. It does not replace the fixed systems the Egyptian code requires for each building type.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ad7179 elementor-widget elementor-widget-text-editor\" data-id=\"3ad7179\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>The European classification, EN 2, uses classes A, B, C, D and F. The American classification in NFPA 10 uses A, B, C, D and K.<\/li><li>Class C means flammable gases in the European system, but energised electrical equipment in the American system.<\/li><li>ABC dry powder is the multi-purpose option, CO2 suits electrical equipment, AFFF foam is for flammable liquids, and wet chemical is for cooking oils.<\/li><li>The hazard sets the type; floor area, travel distance, the code and civil protection set the number and layout.<\/li><li>NFPA 10 calls for monthly visual inspection and annual maintenance; manufacturer instructions and Egyptian standards set the details per model.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fcd67e elementor-widget elementor-widget-text-editor\" data-id=\"4fcd67e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire classes: the European and American systems<\/h2>\n<p>Fires are classed by the burning fuel, and every extinguisher label shows the classes it was tested on. Many extinguishers sold in Egypt are made and tested to the European EN 3 series and Egyptian standards, so EN 2 classes are most common. NFPA classes appear where specifications follow American standards.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Fuel type<\/th><th>European class (EN 2)<\/th><th>American class (NFPA 10)<\/th><\/tr><\/thead><tbody><tr><td>Ordinary combustible solids: wood, paper, fabric, many plastics<\/td><td>A<\/td><td>A<\/td><\/tr><tr><td>Flammable liquids: petrol, diesel, solvents, paints<\/td><td>B<\/td><td>B (also covers flammable gases)<\/td><\/tr><tr><td>Flammable gases: natural gas, LPG (butane cylinders), acetylene<\/td><td>C<\/td><td>Included in B<\/td><\/tr><tr><td>Energised electrical equipment<\/td><td>No separate class; suitability is proven by a dielectric test<\/td><td>C<\/td><\/tr><tr><td>Combustible metals: magnesium, sodium, titanium<\/td><td>D<\/td><td>D<\/td><\/tr><tr><td>Cooking oils and fats<\/td><td>F<\/td><td>K<\/td><\/tr><\/tbody><\/table><\/div>\n<p>In the European system, EN 3-7 includes a dielectric (electrical insulation) test. An extinguisher that passes can be marked for use on live equipment up to 1,000 V from one metre. Read the label; do not judge electrical safety by the agent alone.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb243d6 elementor-widget elementor-widget-text-editor\" data-id=\"cb243d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Types of fire extinguishers and their uses<\/h2>\n<h3>ABC dry powder extinguisher<\/h3>\n<p>The most common type: it covers solids, liquids and gases and interrupts the chemical reaction of combustion. Drawbacks: the powder cuts visibility in enclosed rooms, leaves residue that can damage sensitive electronics, and is not the right choice for cooking-oil fires in commercial kitchens.<\/p>\n<h3>Carbon dioxide (CO2) extinguisher<\/h3>\n<p>CO2 displaces oxygen, with some cooling, and leaves no residue, so it suits electrical panels, equipment rooms and liquid fires. It is not suitable for solids, which can reignite once the gas disperses, or for frying oil. Use it with care in small occupied rooms, as it lowers oxygen levels.<\/p>\n<h3>AFFF foam extinguisher<\/h3>\n<p>AFFF (aqueous film-forming foam) blankets the burning liquid and seals it from the air. It covers Class A and B fires, so it suits flammable-liquid stores, workshops and fuel stations. Do not use it on electrical equipment unless the label confirms a passed dielectric test.<\/p>\n<h3>Water extinguisher<\/h3>\n<p>Water cools the burning material and is suitable for Class A only. Never use it on burning liquids, as it can spread the fire, or on electrical equipment, because water conducts electricity.<\/p>\n<h3>Wet chemical extinguisher<\/h3>\n<p>Made for cooking oils and fats (Class F in Europe, K in the US). The solution reacts with the oil to form a soap-like layer that seals and cools the surface. In commercial kitchens it supports the fixed suppression system over the cooking line; it does not replace it. For details, see <a href=\"\/en\/eg\/solutions\/kitchen-fire-suppression-egypt\/\">commercial kitchen fire suppression systems<\/a>.<\/p>\n<h3>Clean agent extinguisher<\/h3>\n<p>Uses agents that leave no residue and do not conduct electricity, so it suits server rooms, control rooms and sensitive equipment. Its capacity per kilogram is usually lower than powder, so a larger unit is needed for the same hazard.<\/p>\n<h3>Class D extinguishers<\/h3>\n<p>Metal fires need special powders matched by the manufacturer to the metal; standard ABC units will not work. If you handle combustible metals, consult the design engineer and a specialist supplier.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acd40bb elementor-widget elementor-widget-text-editor\" data-id=\"acd40bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Extinguisher suitability by hazard<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Extinguisher type<\/th><th>Solids (A)<\/th><th>Liquids (B)<\/th><th>Gases (European C)<\/th><th>Electrical<\/th><th>Cooking oils (F\/K)<\/th><\/tr><\/thead><tbody><tr><td>ABC powder<\/td><td>Suitable<\/td><td>Suitable<\/td><td>Suitable<\/td><td>Suitable if it passed the dielectric test<\/td><td>Not suitable<\/td><\/tr><tr><td>CO2<\/td><td>Not suitable<\/td><td>Suitable<\/td><td>Not intended<\/td><td>Suitable<\/td><td>Not suitable<\/td><\/tr><tr><td>AFFF foam<\/td><td>Suitable<\/td><td>Suitable<\/td><td>Not suitable<\/td><td>Only if stated on the label<\/td><td>Not suitable<\/td><\/tr><tr><td>Water<\/td><td>Suitable<\/td><td>Not suitable<\/td><td>Not suitable<\/td><td>Not suitable<\/td><td>Not suitable<\/td><\/tr><tr><td>Wet chemical<\/td><td>Depends on model<\/td><td>Not intended<\/td><td>Not suitable<\/td><td>Not suitable<\/td><td>Suitable<\/td><\/tr><tr><td>Clean agent<\/td><td>Depends on rating<\/td><td>Suitable<\/td><td>Not intended<\/td><td>Suitable<\/td><td>Not suitable<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The label and model datasheet always take priority; the table shows the general picture only. With a gas fire, shut off the gas before putting out the flame.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f5d14d elementor-widget elementor-widget-text-editor\" data-id=\"0f5d14d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Choosing extinguishers by type of space<\/h2>\n<ul><li><strong>Offices, administrative and residential buildings:<\/strong> ABC powder or foam in corridors; CO2 by electrical panels and server rooms.<\/li><li><strong>Commercial kitchens:<\/strong> wet chemical near the fryers, alongside the fixed hood system, plus CO2 or powder for electrical panels.<\/li><li><strong>Factories and warehouses:<\/strong> larger ABC powder units, foam in liquid stores, and wheeled powder units for large or high-hazard areas.<\/li><li><strong>Electrical and generator rooms:<\/strong> CO2, or ceiling-mounted automatic units where the room is mostly unattended.<\/li><li><strong>Data centres and control rooms:<\/strong> CO2 or clean agent, with a fixed suppression system where the design calls for one.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7b5db0 elementor-widget elementor-widget-text-editor\" data-id=\"a7b5db0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Extinguisher placement: the basic concepts<\/h2>\n<p>The number and location of extinguishers are set by the Egyptian code, civil protection requirements for the occupancy, and the reference standard in the specification. These rely on a few key concepts:<\/p>\n<ul><li><strong>Travel distance:<\/strong> the maximum walk to reach an extinguisher. For example, NFPA 10 sets a maximum of 75 ft (about 23 m) for Class A hazards and 30 ft (about 9 m) for Class K extinguishers in kitchens.<\/li><li><strong>Fire rating:<\/strong> the number before the class letter on the label, such as 27A or 144B, reflecting the size of the test fire put out. Use it, not weight alone, to calculate how many units you need.<\/li><li><strong>Visibility and access:<\/strong> near exits and escape routes, on brackets or in marked cabinets, unobstructed and signed.<\/li><li><strong>Protection from the surroundings:<\/strong> away from heat, corrosion and impact, or in cabinets outdoors.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe91072 elementor-widget elementor-widget-text-editor\" data-id=\"fe91072\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Inspection and maintenance: what the references say<\/h2>\n<p>Keep the source of each requirement clear. In the American reference, NFPA 10 (2026 edition) requires a visual inspection at least every 30 days, and this edition allows electronic monitoring or performance-based programmes with the approval of the authority having jurisdiction. It adds annual maintenance by a qualified technician, plus internal examinations and hydrostatic tests that vary by type. For example, stored-pressure dry powder units need internal maintenance every six years and a hydrostatic test every twelve years.<\/p>\n<p>In Egypt, the Egyptian extinguisher standards, the manufacturer&#8217;s instructions and civil protection requirements decide what applies. NFPA intervals are not an Egyptian legal obligation. Good practice in all cases:<\/p>\n<ul><li>Routine checks that the unit is in place, the pin and tamper seal are intact, the gauge is in the green, and there is no damage or corrosion.<\/li><li>Weighing CO2 extinguishers periodically, as they usually have no pressure gauge.<\/li><li>Recharging immediately after any use, even partial.<\/li><li>A maintenance tag on every extinguisher and a central log of dates and remarks.<\/li><\/ul>\n<p>For planned maintenance of fire systems, see <a href=\"\/en\/eg\/services\/\">our services<\/a> and our article on <a href=\"\/en\/eg\/media-center\/fire-system-maintenance-inspection-egypt\/\">fire fighting and fire alarm system maintenance<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d433b9d elementor-widget elementor-widget-text-editor\" data-id=\"d433b9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>PYRAMID extinguishers available from AZEIDK Egypt<\/h2>\n<p>AZEIDK Egypt supplies <a href=\"\/en\/eg\/brands\/pyramid\/\">PYRAMID<\/a> extinguishers in the following types:<\/p>\n<ul><li>Stored-pressure ABC dry powder in 1, 3, 6, 9 and 12 kg, to EN 3 and Egyptian standard ES 8442\/2021, with powder to EN 615 and ES 4833. Approved by the Egyptian Organization for Standardization and Quality (EOS) and carrying the Egyptian quality mark.<\/li><li>Wheeled powder units in 25 and 50 kg, to EN 1866 and ES 1494.<\/li><li>Fire Search automatic powder extinguishers in 6 and 12 kg, actuated by a linear detection tube.<\/li><li>CO2 in 2, 3, 6, 10, 20 and 30 kg, to EN 3 and ES 735, approved by EOS, plus Fire Search automatic CO2 models in 3, 6 and 10 kg.<\/li><li>AFFF foam in 6 and 9 litres, to EN 3 and ES 711 and approved by EOS, plus wheeled models in 25 and 45 litres.<\/li><\/ul>\n<p>Wet chemical, water and clean agent units are outside this range and are sourced per project. See our <a href=\"\/en\/eg\/solutions\/fire-extinguishers-egypt\/\">fire extinguisher solutions<\/a> to choose the right type and size.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57a2c11 elementor-widget elementor-widget-text-editor\" data-id=\"57a2c11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes when choosing and using extinguishers<\/h2>\n<ul><li><strong>One extinguisher for every hazard:<\/strong> powder everywhere, including the commercial kitchen and server room.<\/li><li><strong>Using water or CO2 on frying oil:<\/strong> this can throw burning oil out and spread the fire.<\/li><li><strong>Judging by weight, not by rating:<\/strong> two extinguishers of the same weight can have very different fire ratings.<\/li><li><strong>Hiding the extinguisher:<\/strong> behind doors or stock, or left on the floor without a bracket.<\/li><li><strong>Skipping training:<\/strong> staff who do not know how to use extinguishers or their limits.<\/li><li><strong>Delaying the recharge:<\/strong> rehanging a partly used unit as if it were ready.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b12003 elementor-widget elementor-widget-text-editor\" data-id=\"6b12003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the best extinguisher for a home or office?<\/h3><\/summary><p>ABC powder covers most common hazards; add CO2 by electrical panels and electronics. Number and size depend on floor area and applicable requirements.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can a powder extinguisher be used on an electrical fire?<\/h3><\/summary><p>Yes, if it has passed the dielectric test and the label says so. Isolate the power whenever possible. CO2 is preferred for sensitive equipment because it leaves no residue.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the difference between Class F and Class K?<\/h3><\/summary><p>Both refer to fires in cooking oils and fats. F is the European EN 2 class; K is the American NFPA 10 class.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How often should an extinguisher be inspected?<\/h3><\/summary><p>NFPA 10 recommends a visual inspection every 30 days and annual maintenance. In Egypt, follow the manufacturer&#8217;s instructions, Egyptian standards and the civil protection requirements for your facility.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When do I need an automatic extinguisher?<\/h3><\/summary><p>In mostly unattended spaces such as electrical rooms, generator rooms and small stores, where the unit discharges on its own on rising heat or through its detection tube.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-919246c elementor-widget elementor-widget-text-editor\" data-id=\"919246c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2><p>Across all the types of fire extinguishers and their uses, the right one matches the fuel in the space, carries the required rating, sits where people can reach it quickly, and is kept ready by inspection and maintenance. Identify the hazards first, choose type and size per the Egyptian code and the specified reference standard, and check the datasheet before you buy.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2931c49 elementor-widget elementor-widget-text-editor\" data-id=\"2931c49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need to know which extinguishers your facility needs, and how many?<\/strong> Send us your activity and floor areas, and we will recommend the right types and sizes. <a href=\"\/en\/eg\/contact\/\">Talk to the AZEIDK Egypt team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f617983 elementor-widget elementor-widget-text-editor\" data-id=\"f617983\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-10-standard-development\/10\" rel=\"noopener\" target=\"_blank\">NFPA 10: Standard for Portable Fire Extinguishers<\/a> (NFPA), <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/10\/10_SDR_A2025.pdf\" rel=\"noopener\" target=\"_blank\">NFPA 10 Second Draft Report (2026 edition cycle)<\/a> (NFPA), <a href=\"https:\/\/knowledge.bsigroup.com\/products\/classification-of-fires-1\" rel=\"noopener\" target=\"_blank\">BS EN 2: Classification of fires<\/a> (BSI), <a href=\"https:\/\/www.fia.uk.com\/news\/fact-file-97-en-3-7-dielectric-test.html\" rel=\"noopener\" target=\"_blank\">Fact File 97: EN 3-7 Dielectric Test<\/a> (Fire Industry Association), and <a href=\"https:\/\/www.osha.gov\/etools\/evacuation-plans-procedures\/emergency-standards\/portable-extinguishers\/about\" rel=\"noopener\" target=\"_blank\">Portable Fire Extinguishers: Extinguisher Basics<\/a> (OSHA)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Types of fire extinguishers and their uses: EN 2 and NFPA 10 fire classes, where ABC powder, CO2 and AFFF foam fit, plus placement and maintenance basics.<\/p>\n","protected":false},"author":2,"featured_media":16861,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[287],"tags":[],"azeidk_region":[226],"class_list":["post-18077","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eg-technical-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=18077"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18077\/revisions"}],"predecessor-version":[{"id":18087,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/18077\/revisions\/18087"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/16861"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=18077"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=18077"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=18077"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=18077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}