{"id":15069,"date":"2026-05-12T10:00:00","date_gmt":"2026-05-12T10:00:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/saudi-building-code-sbc-801-fire-protection\/"},"modified":"2026-10-29T19:04:04","modified_gmt":"2026-10-29T19:04:04","slug":"saudi-building-code-sbc-801-fire-protection","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/saudi-building-code-sbc-801-fire-protection\/","title":{"rendered":"Saudi Fire Protection Code (SBC 801): A Practical Guide"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"15069\" class=\"elementor elementor-15069 elementor-14587 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bbe852b e-con-full az-el-article e-flex e-con e-parent\" data-id=\"bbe852b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-97c9e7e elementor-widget elementor-widget-text-editor\" data-id=\"97c9e7e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">The Saudi Fire Protection Code (SBC 801) is the part of the Saudi Building Code that sets minimum requirements for protecting lives and property from fire and explosion hazards, for firefighter and rescuer safety, for emergency and evacuation plans and for firefighting systems. Its 2024 edition has been mandatory since 30 June 2025, and the General Directorate of Civil Defense monitors its fire protection requirements throughout a building&#8217;s life.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fc130d elementor-widget elementor-widget-text-editor\" data-id=\"8fc130d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2>\n<ul>\n<li>SBC 801 is issued by the Saudi Building Code Center; its 2024 edition replaced the 2018 edition and has been mandatory since 30 June 2025.<\/li>\n<li>The Saudi General Building Code (SBC 201) sets occupancy classification, construction types and egress design; SBC 801 covers fire protection systems, fire service features, safe operation and hazardous materials. A project applies both.<\/li>\n<li>SBC 801 follows the layout of the International Fire Code (IFC), but values from IFC or International Building Code (IBC) model texts are not Saudi requirements until confirmed in the Saudi edition.<\/li>\n<li>Under Article 10 of the Implementing Regulation of the Saudi Building Code Application Law, Civil Defense monitors fire prevention and protection requirements at all stages of construction, maintenance, operation and storage.<\/li>\n<li>Civil Defense licenses run through the Salamah portal, so records and maintenance matter long after handover.<\/li>\n<\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2b98e1 elementor-widget elementor-widget-text-editor\" data-id=\"e2b98e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is the Saudi Fire Protection Code (SBC 801)?<\/h2>\n<p>SBC 801 is issued by the <a href=\"https:\/\/sbc.gov.sa\/En\/BC\/Pages\/BuildingCode\/BCDetails.aspx?codeId=801&amp;year=2024\" rel=\"noopener\" target=\"_blank\">Saudi Building Code Center<\/a>, whose code page describes it as a building code for protection from fire and explosion hazards that sets minimum requirements to protect lives and property, provides a suitable level of safety for firefighting and rescue personnel, and covers emergency and evacuation plans and firefighting systems.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0048bf6 elementor-widget elementor-widget-text-editor\" data-id=\"0048bf6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How SBC 801 relates to SBC 201, other codes and the IFC<\/h2>\n<p>The 2024 Saudi Building Code runs from SBC 201 to SBC 1401. Three of its codes shape fire safety most directly:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Code<\/th><th>What it covers<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Saudi General Building Code (SBC 201)<\/td><td>Design, construction, maintenance and operation by use and occupancy: classification, construction types, height and area limits, fire and smoke protection features, means of egress, interior finishes<\/td><\/tr>\n<tr><td>Saudi Fire Protection Code (SBC 801)<\/td><td>Fire and explosion hazards, fire service features, fire protection and life safety systems, means of egress, existing buildings, hazardous materials<\/td><\/tr>\n<tr><td>Saudi Existing Building Code (SBC 901)<\/td><td>Repair, alteration, addition and change of occupancy of existing buildings<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<h3>The link to the International Fire Code<\/h3>\n<p>The Saudi Building Code has been built on the International Codes of the International Code Council (ICC) from the start: ICC announced in 2007 that its 2003 and 2006 codes would be the basis, and states that the 2018 revision was based on the <a href=\"https:\/\/iccsafe.org\/?p=240998\" rel=\"noopener\" target=\"_blank\">2015 International Codes<\/a>. SBC 801 shares chapter titles with the IFC, such as Fire Service Features. The 2024 announcement did not name its international base edition.<\/p>\n<p>Two practical points follow. A value quoted from the IFC or IBC is a model-code value until confirmed in the Saudi edition. And detailed design rests on referenced standards: ICC training on the 2018 SBC 801 teaches participants to identify the National Fire Protection Association (NFPA) standards for designing compliant systems, and the 2024 Code Requirements include a referenced standards chapter. The applicable edition of each standard is the one SBC 801 references or Civil Defense accepts.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-10b067a elementor-widget elementor-widget-text-editor\" data-id=\"10b067a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The 2024 edition: dates and what to check<\/h2>\n<p>The National Committee for the Saudi Building Code announced the 2024 edition on 8 January 2025 with a 180-day transition; it replaced the 2018 edition and has been mandatory since 30 June 2025, as our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/saudi-building-code-sbc-201-801-2024-edition-news-en\/\">2024 Saudi Building Code news<\/a> reports. The Saudi Building Code Application Law provides for the code to be reissued every five years.<\/p>\n<p>Section numbers also moved: inspections are Section 106 in the 2018 Arabic table of contents but Section 108 in the 2024 Code Requirements, which also list sections on gas detection (916) and mass notification (917) absent from the 2018 table. Quote section numbers only from the edition that applies to your permit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b8a2b8 elementor-widget elementor-widget-text-editor\" data-id=\"3b8a2b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Main chapters and topics of SBC 801<\/h2>\n<p>The 2024 table of contents gives chapter titles and section numbers, not chapter numbers, so the table uses section ranges:<\/p>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Chapter<\/th><th>Sections<\/th><th>Main topics<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Scope and Administration<\/td><td>101 to 114<\/td><td>Applicability, permits, construction documents, inspections, maintenance, violations, unsafe buildings<\/td><\/tr>\n<tr><td>Fire Service Features<\/td><td>501 to 510<\/td><td>Fire apparatus access roads, key boxes, fire protection water supplies, fire command center, emergency responder radio coverage<\/td><\/tr>\n<tr><td>Building Services and Systems<\/td><td>601 to 610<\/td><td>Electrical hazards, elevator operation and fire service keys, commercial cooking systems<\/td><\/tr>\n<tr><td>Fire and Smoke Protection Features<\/td><td>701 to 708<\/td><td>Penetrations, joints and voids, door, window and duct openings, concealed spaces<\/td><\/tr>\n<tr><td>Fire Protection and Life Safety Systems<\/td><td>901 to 917<\/td><td>Automatic sprinklers, alternative extinguishing systems, standpipes, portable extinguishers, fire alarm and detection, emergency alarms, smoke control, smoke and heat removal, explosion control, fire department connections, fire pumps, carbon monoxide and gas detection, mass notification<\/td><\/tr>\n<tr><td>Means of Egress<\/td><td>1001 to 1032<\/td><td>Occupant load, number of exits, illumination, exit signs, travel distance, maintenance of the means of egress<\/td><\/tr>\n<tr><td>Construction Requirements for Existing Buildings<\/td><td>1101 to 1106<\/td><td>Fire safety and means of egress in existing buildings<\/td><\/tr>\n<tr><td>Other chapters: special occupancies, operations and hazardous materials<\/td><td>Several chapters<\/td><td>Aviation facilities, motor fuel-dispensing facilities, high-piled combustible storage, construction and demolition, hot work, hazardous materials<\/td><\/tr>\n<tr><td>Appendices<\/td><td>Lettered appendices<\/td><td>Including fire-flow requirements, fire hydrant locations and fire apparatus access roads<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>Further chapters cover general requirements, emergency planning and preparedness, and interior finish, decorative materials and furnishings.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9c5e31 elementor-widget elementor-widget-text-editor\" data-id=\"d9c5e31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How Civil Defense applies SBC 801<\/h2>\n<p>The <a href=\"https:\/\/momah.gov.sa\/sites\/default\/files\/2025-10\/allayht%20altnfydhyt%20lnzam%20ttbyq%20kwd%20albna%20als%60wdy.pdf\" rel=\"noopener\" target=\"_blank\">Implementing Regulation of the Saudi Building Code Application Law<\/a> splits the roles. The municipality (amanah or baladiyah) issues a building permit only after checking the documents and plans against the code, and a building may not be occupied before it has an occupancy certificate.<\/p>\n<p>Article 10 gives the General Directorate of Civil Defense, without prejudice to other bodies&#8217; roles, the task of monitoring the application of the code and recording violations of the fire prevention and protection requirements at all stages of construction, maintenance, operation and storage, so fire protection is checked across the building&#8217;s life.<\/p>\n<p>Facilities obtain and renew Civil Defense licenses through the Salamah portal, as our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/salamah-platform-civil-defense-license-digital-news-en\/\">Salamah update<\/a> explains, and our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/civil-defense-fire-safety-approval-saudi-arabia\/\">Civil Defense approval guide<\/a> covers the approval steps. Under the Saudi Building Code Application Law, a violation must first be corrected within a set period; otherwise a violations committee can impose fines of up to SAR 1 million per violation in a single building, license suspension of one month to one year, or both.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3b71a1 elementor-widget elementor-widget-text-editor\" data-id=\"d3b71a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What owners and contractors should do<\/h2>\n<ol>\n<li>Confirm the code edition that applies to the permit; projects designed or permitted now fall under the 2024 edition.<\/li>\n<li>Fix the occupancy classification under the Saudi General Building Code first; fire protection requirements build on it.<\/li>\n<li>Have the consultant list the SBC 801 sections and referenced standard editions in the design basis, and flag any value taken from IFC or IBC texts.<\/li>\n<li>Bring Civil Defense requirements into the design stage, not the inspection.<\/li>\n<li>Specify listed or approved equipment and check SABER conformity for each product; our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/en54-fire-alarm-standard-guide\/\">EN 54 guide<\/a> explains fire alarm approval routes.<\/li>\n<li>Test and commission every system, and keep approved and as-built drawings, test certificates and maintenance contracts on file.<\/li>\n<li>Review fire protection before any extension, change of use or license renewal, applying SBC 901 when the building is altered.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65f3b7c elementor-widget elementor-widget-text-editor\" data-id=\"65f3b7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes and what drives compliance cost<\/h2>\n<ul>\n<li>Treating IFC or IBC values found online as Saudi requirements.<\/li>\n<li>Quoting 2018 section numbers on a project under the 2024 edition.<\/li>\n<li>Assuming a UL, FM, EN 54 or <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/saber-saleem-fire-safety-products-conformity-news-en\/\">SABER certificate<\/a> approves the installed system.<\/li>\n<li>Leaving Civil Defense requirements until installation is complete.<\/li>\n<li>Letting maintenance records lapse until license renewal.<\/li>\n<\/ul>\n<p>Compliance cost depends mainly on the building&#8217;s occupancy and size, which set the systems required; the water supply and fire pumps; how early Civil Defense requirements enter the design; the equipment approval route; and, in existing buildings, the gap between installed systems and the current edition.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99e5c74 elementor-widget elementor-widget-text-editor\" data-id=\"99e5c74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK helps<\/h2>\n<p>AZEIDK supports owners and contractors from assessment to maintenance, backed by 16+ years in the Saudi market and 17+ branches and service regions, through <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/services\/assessment-of-existing-systems-scope-of-work-definition\/\">assessment of existing systems and scope definition<\/a>, <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/services\/engineering-design-calculations\/\">engineering design and calculations<\/a> and <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance contracts<\/a>.<\/p>\n<p>Our <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> covers reviewing the requirements and documents the project needs, coordinating drawings and technical reports, identifying compliance observations and organizing follow-up, without guaranteeing an approval outcome, which rests with the competent authorities.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16b4eda elementor-widget elementor-widget-text-editor\" data-id=\"16b4eda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>Is the Saudi Fire Protection Code mandatory?<\/h3><\/summary><p>Yes. It is part of the Saudi Building Code, whose 2024 edition has been mandatory since 30 June 2025, and municipalities and Civil Defense enforce it under the Saudi Building Code Application Law. Which provisions apply depends on the building&#8217;s occupancy, size and use, and on whether it is new or existing, so confirm the scope with your consultant.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the difference between SBC 801 and SBC 201?<\/h3><\/summary><p>SBC 201 covers building design by use and occupancy: classification, construction types, height and area limits, fire and smoke protection features and means of egress. SBC 801 covers fire and explosion hazards, fire service features, fire protection systems, safe operation and hazardous materials. Both contain egress provisions and a fire protection systems chapter (Sections 901 to 918 in the 2024 SBC 201), so a project applies both together.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is SBC 801 the same as the International Fire Code?<\/h3><\/summary><p>No. It is a Saudi code built on the ICC model that shares chapter titles with the IFC; ICC states that the 2018 Saudi Building Code was based on the 2015 International Codes. The 2024 announcement named no base edition, so treat IFC text as a model reference and confirm every value in SBC 801.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Which NFPA edition does SBC 801 require?<\/h3><\/summary><p>Check the referenced standards chapter of the SBC 801 edition that applies to your project, and confirm with Civil Defense. We do not quote an edition here, because the binding source is the referenced standards chapter of the edition that applies. State the edition you design to in the design basis, and keep every submittal consistent with it.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Who enforces the Saudi Fire Protection Code?<\/h3><\/summary><p>Municipalities issue building permits and occupancy certificates after checking code compliance. Under Article 10 of the Implementing Regulation, the General Directorate of Civil Defense monitors fire prevention and protection requirements at all stages of construction, maintenance, operation and storage, and facilities obtain and renew Civil Defense licenses through the Salamah portal.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does SBC 801 apply to existing buildings?<\/h3><\/summary><p>Yes, in part. The 2024 Code Requirements include construction requirements for existing buildings (Sections 1101 to 1106) and maintenance provisions, and the Saudi Existing Building Code (SBC 901) covers repair, alteration, addition and change of occupancy. Review fire protection with your consultant before any extension, change of use or license renewal.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d03825f elementor-widget elementor-widget-text-editor\" data-id=\"d03825f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> the <a href=\"https:\/\/sbc.gov.sa\/En\/BC\/Pages\/BuildingCode\/BCDetails.aspx?codeId=801&amp;year=2024\" rel=\"noopener\" target=\"_blank\">SBC 801 Saudi Fire Protection Code page<\/a> and the <a href=\"https:\/\/sbc.gov.sa\/ar\/BC\/Documents\/tableofcontent2024\/SBC%20801\/SBC801_CR_241224-FA.pdf\" rel=\"noopener\" target=\"_blank\">2024 Code Requirements table of contents<\/a> of the Saudi Building Code Center, the <a href=\"https:\/\/momah.gov.sa\/sites\/default\/files\/2025-10\/allayht%20altnfydhyt%20lnzam%20ttbyq%20kwd%20albna%20als%60wdy.pdf\" rel=\"noopener\" target=\"_blank\">Implementing Regulation of the Saudi Building Code Application Law<\/a> and the <a href=\"https:\/\/momah.gov.sa\/sites\/default\/files\/2025-10\/nzam%20ttbyq%20kwd%20albna%20als%60wdy1.pdf\" rel=\"noopener\" target=\"_blank\">Saudi Building Code Application Law<\/a> (Ministry of Municipalities and Housing, in Arabic), the <a href=\"https:\/\/www.aleqt.com\/2025\/01\/08\/article_2755302.html\" rel=\"noopener\" target=\"_blank\">announcement of the 2024 edition and its mandatory date<\/a> (Al-Eqtisadiah, 8 January 2025, in Arabic), and the <a href=\"https:\/\/iccsafe.org\/?p=240998\" rel=\"noopener\" target=\"_blank\">ICC page on the Saudi Building Code<\/a>.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87e3044 elementor-widget elementor-widget-text-editor\" data-id=\"87e3044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need your facility reviewed against the current code?<\/strong> Send our engineers your drawings and how the facility is used, and we will assess its fire protection systems and define the scope of work. <a href=\"https:\/\/azeidkgroup.com\/en\/sa\/contact\/\">Contact the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>What the Saudi Fire Protection Code (SBC 801) covers, how it relates to SBC 201 and the IFC, how Civil Defense enforces it and what owners should do.<\/p>\n","protected":false},"author":2,"featured_media":16549,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[],"azeidk_region":[223],"class_list":["post-15069","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/15069","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=15069"}],"version-history":[{"count":4,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/15069\/revisions"}],"predecessor-version":[{"id":18012,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/15069\/revisions\/18012"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/16549"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=15069"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=15069"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=15069"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=15069"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}